The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

38301–38325 of 40356

  • HighFDA (Devices)·Z-1367-2013·2013-05-29

    Separation Technology Recalls SlidePrep Plus Cytology Centrifuges for Unexpected Startup

    Separation Technology, Inc. is recalling SlidePrep Plus Cytology Centrifuges manufactured before January 1, 2013, because they may start up unexpectedly when exposed to electrostatic discharge.

    Product
    SLIDERPREP PLUS SLIDE PREPARATION CENTRIFUGE. Produce a monolayer of cells onto a glass slide from any fluid suspension.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1368-2013·2013-05-29

    Roche Cobas 8000 Software Recall for Incorrect Immunoassay Results

    Roche Diagnostics is recalling software for the cobas e 602 module because it may produce incorrect test results under specific conditions.

    Product
    Cobas¿ 8000 modular analyzer series software version 03-01, 02, 03 and 04, impacting the cobas e 602 module only. Product Usage: Fully automated immunoassay analyzer intended for the in-vitro quantitative/qualitative determination of analytes in body fluids. This analyzer is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1365-2013·2013-05-29

    Medical Information Technology Recalls Bi-Directional Communication Analyzer Interface

    Medical Information Technology, Inc. is recalling 56 MEDITECH Bi-Directional interactive Communication Analyzer Interface devices due to incorrect transmission of laboratory results.

    Product
    MEDITECH Bi-Directional interactive Communication Analyzer Interface; Integrates with MEDITECH's Laboratory Information System (LIS) with Other Vendor systems to manage the transfer of patient results and demographic information.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1346-2013·2013-05-29

    Roche Recalls cobas 4800 Systems Due to Rare Channel Shift Errors

    Roche Molecular Systems is recalling 425 cobas 4800 systems because rare channel-shift errors may cause test results to be reported in the wrong channel.

    Product
    cobas¿ 4800 system z480 instrument. Integrates fully automated total nucleic acid isolation directly from secondary sample tubes.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1361-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical Inc. is recalling PTFE Coated Disposable Electrosurgical Electrodes because product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - NON-STICK CAUTERY TIP PTFE Coated Needle 2.75" (6.99cm) Length, Product number P0013 Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes used…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1355-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Laparoscopic Electrodes

    Progressive Medical is recalling PTFE coated laparoscopic electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes -Laparoscopic Electrode PTFE Coated Curved Blade 33cm Length, Product number P0019 Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1363-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Laparoscopic Electrosurgical Electrodes

    Progressive Medical Inc. is recalling PTFE Coated Disposable Electrosurgical Electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - Laparoscopic Electrode PTFE Coated J- Hook 44cm Length, Product number P0021X Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1353-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical Inc. is recalling PTFE Coated Disposable Electrosurgical Electrodes because product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - Laparoscopic Electrode PTFE Coated L Hook 44cm Length, Product number P0020X Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1360-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Laparoscopic Electrosurgical Electrodes

    Progressive Medical is recalling PTFE coated laparoscopic electrosurgical electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - Laparoscopic Electrode PTFE Coated J Hook 33cm Length, Product number P0021, Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1354-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical Inc. is recalling PTFE Coated Disposable Electrosurgical Electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - NON-STICK CAUTERY TIP PTFE Modified Coated Blade 2.50" (6.40cm) Length, Product number P0012M Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1217-2013·2013-05-29

    Cefla Dental X-Ray Units Recalled for Missing Safety Labels

    Cefla Dental Group is recalling 173 MyRay RXDC dental x-ray units because they lack required certification and identification labels.

    Product
    MyRay RXDC dental unit x-ray unit
    Category
    Medical Device
    Distribution
    22 states
  • ModerateFDA (Devices)·Z-1339-2013·2013-05-29

    Boston Scientific Recalls LATITUDE Patient Management System Software

    Boston Scientific is recalling the LATITUDE Patient Management System software because a system update caused clinic faxes to display illegible characters instead of required patient information.

    Product
    LATITUDE¿ Patient Management System, Model 6488, Version 7.3. The LATITUDE Patient Management system is intended for use to remotely communicate with a compatible Boston Scientific pulse generator and transfer data to a central database.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1341-2013·2013-05-29

    Coloplast Recalls Mislabeled Restorelle L Prostheses Due to Incorrect Instructions

    Coloplast is recalling 111 units of Restorelle L prostheses because the packaging contains incorrect Instructions For Use pamphlets.

    Product
    Rostorelle L, Polypropylene Mesh, Catalog number 501440, Manufacturer Coloplast A/S 3050 Denmark.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1356-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical is recalling PTFE coated disposable electrosurgical electrodes because product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes -NON-STICK CAUTERY TIP PTFE Modified Coated Blade 6.5" (16.51cm) Length, Product number P0014M Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1338-2013·2013-05-29

    Philips CT Systems Recall for Incorrect CTDIVol Data Storage

    Philips is recalling 515 CT systems because they stored the sum of CTDIVol values instead of individual slice values, resulting in incorrect data.

    Product
    Brilliance CT 16-Slice Water, System Code: 728245; Brilliance CT 10-Slice Water, System Code: 728250; Brilliance CT 6-Slice Water, System Code: 728255; MX8000 IDT 16, System Code: 728120 & MX8000 IDT 10, System Code: 728125 Computed Tomography X-ray systems. Distributed by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1364-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical is recalling PTFE Coated Disposable Electrosurgical Electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - Push Button Pencil With PTFE Blade and Holster, Product number P0035H Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Rx Only Electrodes used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1340-2013·2013-05-29

    ConMed Linvatec VP1600 HD Still Capture System Software Recall

    ConMed Linvatec is recalling 267 VP1600 HD Still Capture Systems due to a software anomaly that may cause the device to lock up.

    Product
    Ref: VP1600 HD Still Capture System ConMed Linvatec . Captures, stores and transfers images generated by a medical endoscopic camera system during surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1348-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical Inc. is recalling PTFE Coated Disposable Electrosurgical Electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - NON-STICK CAUTERY TIP PTFE Modified Coated Needle 2.75" (6.99cm) Length, Product number P0013M, Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1359-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical Inc. is recalling PTFE Coated Disposable Electrosurgical Electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - Laparoscopic Electrode PTFE Coated Wire L Hook Split 33cm Length,Product number P0020S Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1349-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Electrosurgical Electrodes

    Progressive Medical is recalling PTFE Coated Disposable Electrosurgical Electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - NON-STICK CAUTERY TIP PTFE Coated Blade 6.5" (16.51cm) Length, Product number P0014, Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes used…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1347-2013·2013-05-29

    Unimed Recalls Laparoscopic Electrode Hooks Due to Coating Material Changes

    Unimed Surgical Products is recalling 120,416 laparoscopic electrode hooks due to changes in PTFE coating materials. The devices were distributed in Missouri, Tennessee, and Pennsylvania.

    Product
    PROGRESSIVE MEDICAL Laparoscopic Electrode PTFE Coated L Hook 33cm. Intended for the cutting of soft tissue and coagulation.
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1351-2013·2013-05-29

    Progressive Medical Recalls PTFE Coated Disposable Electrosurgical Electrodes

    Progressive Medical Inc is recalling PTFE Coated Disposable Electrosurgical Electrodes because the product coatings require 510K approval.

    Product
    Progressive Medical PTFE Coated Disposable Electrosurgical Electrodes - NON-STICK CAUTERY TIP PTFE Coated Blade 2.50" (6.40) Length, Product number P0012, Rx Only. Sterilized by Radiation. Manufactured for Progressive Medical, Inc., St. Louis, MO 63128. Electrodes used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1370-2013·2013-05-29

    Stryker Triathlon Femoral Distal Augment Recalled for Packaging Label Errors

    Stryker Howmedica Osteonics is recalling 11 units of Triathlon Femoral Distal Augments due to external packaging label errors, including an incorrect glyph and missing size reference.

    Product
    Stryker Orthopaedics Triathlon Femoral Distal Augment- Left; 1 single unit per package Howmedica Osteonics Corp. 325 Corporate Drive, Mahwah, NJ 07430 USA Stryker France, ZAC Satolas Green Pusignan, Av de Satoles Green 69881 Meyzieu, Cedex, France This device is used…
    Category
    Medical Device
    Distribution
    Distributed nationwide