The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

31651–31675 of 40325

  • HighFDA (Devices)·Z-0157-2016·2015-10-28

    Smith & Nephew MOSAICPLASTY DP- Disposable Harvesting System Recalled for Packaging Breach

    Smith & Nephew is recalling 1,347 units of the MOSAICPLASTY DP- Disposable Harvesting System because a packaging breach compromised the device's sterility.

    Product
    Smith & Nephew MOSAICPLASTY DP- Disposable Harvesting System 6.5 mm, Sterile Part Number: 7209236 Intended Use: For arthroscopic (knee and ankle) and open osteochondral grafting fix for osteochondral (cartilage) defects.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0133-2016·2015-10-28

    Cardinal Health Recalls Ambitex NMD400 Nitrile Exam Gloves Due to Leak Test Failure

    Cardinal Health is recalling Ambitex NMD400 Nitrile Exam Gloves (size medium) because samples failed FDA water leak tests, compromising their barrier function.

    Product
    Ambitex NMD400 Nitrile Exam Gloves size medium. General Hospital and Personal use. Intended to be worn on the hand for medical purposes to provide a barrier against potentially infectious materials and other contaminants.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0154-2016·2015-10-28

    Berchtold TELETOM Equipment Management System Recall for Control Malfunction

    Berchtold Corp. is recalling TELETOM Equipment Management Systems 4 and 6 series due to potential control and brake failure caused by fluid intrusion.

    Product
    TELETOM EQUIPMENT MANAGEMENT SYSTEM 4 and 6 series TELETOM is designed for use in operating rooms, medical treatment rooms, intensive care units, or any area of a medical facility that requires a ceiling mounted device to supply power, medical gases, and data-communication…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0156-2016·2015-10-28

    Smith & Nephew MOSAICPLASTY Harvesting System Recalled for Packaging Breach

    Smith & Nephew is recalling MOSAICPLASTY DP- Disposable Harvesting Systems because a breach in the packaging compromised the device's sterility.

    Product
    Smith & Nephew MOSAICPLASTY DP- Disposable Harvesting System 4.5 mm, Sterile Part Number: 7209235 Intended Use: For arthroscopic (knee and ankle) and open osteochondral grafting fix for osteochondral (cartilage) defects.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0131-2016·2015-10-28

    Encore Medical Recalls AltiVate Humeral Socket Shell Trial Due to Assembly Issues

    Encore Medical is recalling 20 units of the AltiVate Humeral Socket Shell Trial because the shell trial has difficulty assembling to the broach and the retaining ring disassembles from the screw.

    Product
    AltiVate Humeral Socket Shell Trial, Part Number 804-06-052 The glenoid baseplate is intended for cementless application with addition of screws for fixation. The humeral stem is intended for cemented or cementless use. This device may also be indicated in the salvage of…
    Category
    Medical Device
    Distribution
    4 states
  • ModerateFDA (Devices)·Z-0143-2016·2015-10-28

    ConForMIS iDuo Knee Replacement Recalled for Ethylene Glycol Residue

    ConforMIS, Inc. is recalling 12 units of the iDuo Knee Bicompartmental Knee Replacement System because they may contain small amounts of ethylene glycol residue.

    Product
    ConForMIS iDuo Knee Bicompartmental Knee Replacement System , iDUO G2, Right Medial Catalog Number: M57230600220 (US) M5723INT0600220 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0152-2016·2015-10-28

    Smiths Medical Recalls Port-A-Cath Needles Due to Incorrect Labeling

    Smiths Medical ASD, Inc. is recalling Port-A-Cath Plastic Hub Needles from Lot 46262 because the lid stock labels contain incorrect part numbers, descriptions, and images.

    Product
    PORT-A-CATH Plastic Hub Needles, 0.9mm (20G) x 19mm (3/4 in.) 90-degree. REF 21-2287-24 The Plastic hub PORT-A-CATH (PAC) needles are intended to access the implantable portal system for the purpose of infusion or withdrawal of fluids. These PAC needles can be used with…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0147-2016·2015-10-28

    ConFormis iTotal Knee Replacement System Recalled for Ethylene Glycol Residue

    ConforMIS is recalling 110 units of the iTotal Posterior Stabilized Knee Replacement System because they may contain small amounts of ethylene glycol residue.

    Product
    ConFormis iTotal Posterior Stabilized Knee Replacement System- ITOTAL PS-IPOLY- IMPLANT KIT-LEFT and ITOTAL PS-IPOLY-IMPLANT KIT-RIGHT Catalog Number:TPS1111111
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0137-2016·2015-10-28

    Biomet Thinflap System Cases Recalled Due to Lid Opening Difficulty

    Biomet Microfixation is recalling 5 Thinflap System Cases because the lids require excessive force to open.

    Product
    Thinflap System Case The cases hold surgical instrumentation in place during handling and storage.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0134-2016·2015-10-28

    Synthes Recalls Spinal Pedicle Fixation Rods Due to Finishing Process Error

    Synthes (USA) Products LLC is recalling 492 spinal pedicle fixation rods because they were produced using a bead blast process not identified in the manufacturing specification.

    Product
    5.0mm Unit Rod 270mm, 5.0mm Unit Rod 290mm, 5.0mm Unit Rod 310mm, 5.0mm Unit Rod 330mm, 5.0mm Unit Rod 350mm, 5.0mm Unit Rod 370mm, 5.0mm Unit Rod 390mm, 5.0mm Unit Rod 410mm, 5.0mm Unit Rod 430mm, 5.0mm Unit Rod 450mm; Orthosis, Spinal, Pedicle fixation Intended to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0144-2016·2015-10-28

    ConFormis iTotal CR Knee Replacement System Recalled for Ethylene Glycol Residue

    ConforMIS, Inc. is recalling 3 units of the iTotal CR Knee Replacement System because they may contain small amounts of ethylene glycol residue.

    Product
    ConFormis iTotal CR Knee Replacement System- ITOTAL CR - IPOLY - IMPLANT KIT UNCAPTURED - LEFT ITOTAL CR - IPOLY - IMPLANT KIT UNCAPTURED - RIGHT Catalog Number: TCR1111111
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0150-2016·2015-10-28

    B. Braun Recalls Perifix Epidural Anesthesia Trays Due to Discoloration

    B. Braun Medical is recalling 433 Perifix Continuous Epidural Anesthesia Pain Control Trays because the DuraPrep solution may be discolored from unintended sterilant exposure.

    Product
    Perifix Continous Epidural Anesthesia Pain Control Trays; Injection of anesthetics to provide regional anesthesia for pain management.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0146-2016·2015-10-28

    ConFormis iTotal CR Knee Replacement System Recalled for Ethylene Glycol Residue

    ConforMIS, Inc. is recalling 348 units of the iTotal CR Knee Replacement System because they may contain small amounts of ethylene glycol residue.

    Product
    ConFormis iTotal CR Knee Replacement System- iTOTAL CR, Right Knee Catalog Number: M57250600020 (US) M5725INT0600020 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0153-2016·2015-10-28

    OneTray Sealed Sterilization Containers Recalled for Incorrect Labeling

    Innovative Sterilization Technologies LLC is recalling OneTray Sealed Sterilization Containers because the labels list the wrong steam sterilization time.

    Product
    OneTray Sealed Sterilization Containers Product Usage: A rigid sterilization container used to steam sterilize medical devices
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0149-2016·2015-10-28

    Natus neoBLUE 3 Phototherapy System Recalled for Intensity Documentation

    Natus Medical is recalling 4,560 neoBLUE 3 Phototherapy systems because the instruction manuals did not accurately reflect the cleared intensity settings.

    Product
    Natus neoBLUE 3 Phototherapy system or Neonatal Phototherapy, Catalogue Part Number: 010066; Top Assembly Part Number: 001103
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0136-2016·2015-10-28

    Biomet Neuro Combo Set Case Lid Requiring Excessive Force Recalled

    Biomet Microfixation is recalling 37 Neuro Combo Set Cases because the lids require excessive force to open.

    Product
    Neuro Combo Set Case The cases hold surgical instrumentation in place during handling and storage.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0135-2016·2015-10-28

    Philips MRI Systems Recalled for Incorrect Cross-Reference Lines in Spine Imaging

    Philips Medical Systems is recalling specific MRI systems due to a software defect that may cause cross-reference lines to be positioned incorrectly in spine clinical workflows.

    Product
    All Philips Ingenia, Intera, Achieva and Multiva MR systems using R5.1i and R5.1 .2 version of software. Indicated for use as a diagnostic device. It can produce cross-sectional images, spectroscopic images and/or spectra in any orientation of the internal structure of the…
    Category
    Medical Device
    Distribution
    22 states
  • ModerateFDA (Devices)·Z-0140-2016·2015-10-28

    ConForMIS iUNI Knee Replacement Recalled for Ethylene Glycol Residue

    ConForMIS is recalling 6 units of the iUNI Unicondylar Knee Replacement System due to potential ethylene glycol residue.

    Product
    ConForMIS iUNI Unicondylar Knee Replacement System iUNI G2, Right Lateral Catalog Number: M57220600240 (US) M5722INT0600240 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0139-2016·2015-10-28

    ConForMIS Knee Replacement System Recalled for Ethylene Glycol Residue

    ConforMIS, Inc. is recalling 71 units of the ConForMIS Unicondylar Knee Replacement System iUNI G2, Left Medial due to potential small amounts of ethylene glycol residue.

    Product
    ConForMIS Unicondylar Knee Replacement System iUNI G2, Left Medial Catalog Number: M57220600210(US) M5722INT0600210 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0125-2016·2015-10-21

    Synthes Recalls Titanium Elastic Nail Inserters Due to Mechanical Failure Risk

    Synthes (USA) Products LLC is recalling 1,550 Inserter for Titanium Elastic Nails (TEN) devices due to a potential for mechanical failures such as breakage.

    Product
    Inserter for Titanium Elastic Nails (TEN), orthopedic device
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0115-2016·2015-10-21

    ViewRay MRIdian Radiation Therapy System Recalled for Unexpected Couch Movement

    ViewRay is recalling four MRIdian Radiation Therapy Systems because the patient couch may move unexpectedly if an encoder fails and the system is restarted.

    Product
    MRIdian¿ ViewRay¿ Radiation Therapy System, ViewRay¿ Is indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated.
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0119-2016·2015-10-21

    Zimmer Natural Nail CM Long Intramedullary Fixation Rods Recalled for Packaging Defects

    Zimmer GmbH is recalling 57,603 units of Natural Nail CM Long intramedullary fixation rods because compromised outer trays may lead to periprosthetic infection.

    Product
    Zimmer Natural Nail CM Long. Intramedullary Fixation Rod. The Zimmer Natural Nail System is intended for temporary fracture fixation and stabilization of the bone.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0121-2016·2015-10-21

    DJO Monode Shortwave Accessory Recalled for Overheating and Burning Insulation

    DJO, LLC is recalling Monode Shortwave Accessories due to overheating and burning of the wire insulation inside the applicator.

    Product
    Monode, Shortwave Accessory Model #: 02200002 Used in conjunction with the Intelect Shortwave Diathermy 100 and Intelect Shortwave Diathermy 400 units. For the clinical application of electromagnetic energy in the radio frequency of 27.12 megahertz to generate deep heat…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0123-2016·2015-10-21

    Clinical Innovations Recalls Ebb Complete Tamponade System Due to Balloon Leak Risk

    Clinical Innovations, LLC is voluntarily recalling the Ebb Complete Tamponade System due to a potential balloon leak that may prevent the device from delivering therapy when needed.

    Product
    The Ebb Complete Tamponade System, model #CTS-1000 and Code #OQY. Intended for use in providing temporary control or reduction of postpartum uterine bleeding.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0120-2016·2015-10-21

    Ev3 Neurovascular Recalls Pipeline Embolization Devices Due to Incorrect Instructions

    Micro Therapeutics Inc, dba Ev3 Neurovascular, is recalling 23 Pipeline and Pipeline Flex Embolization Devices because they were shipped with EU-version Instructions for Use.

    Product
    -Pipeline Embolization Device -Pipeline Flex Embolization Device The Pipeline and Pipeline Flex Embolization Devices consist of a permanent implant combined with a guidewire based delivery system. The Pipeline and Pipeline Flex embolization device implant is a braided…
    Category
    Medical Device
    Distribution
    9 states