The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

26751–26775 of 40233

  • LowFDA (Devices)·Z-2116-2017·2017-05-24

    Medtest Holdings Recalls Pointe Scientific Hitachi AST Reagent Due to Labeling Discrepancy

    Medtest Holdings is recalling Pointe Scientific Hitachi AST Reagent because the package insert contains inconsistent linearity values in different sections.

    Product
    Pointe Scientific Hitachi AST Reagent R1 : PE plastic bottle w/PP plastic cap. R2: PE plastic bottle w /PP plastic cap. Product Usage: Two Part Chemistry Reagent For the quantitative determination of Aspartate Aminotransferase (ASl) in human serum on Hitachi analyzers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2096-2017·2017-05-24

    Abbott AMO Vitrectomy Cutters Recalled for Packaging Error

    Abbott Medical Optics is recalling 360 AMO Vitrectomy Cutters because 20GA and 25GA models may be packaged in the wrong sizes.

    Product
    AMO 25GA Vitrectomy Cutter (Model Number NGP0025) and AMO 20GA Vitrectomy Cutter and Irrigation Sleeve (Model Number NGP0020) Used with the AMO Whitestar Signature System. For ophthalmic use.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2042-2017·2017-05-17

    Arthrex Recalls Anthrex PEEK SwiveLock SP Vented Anchors Due to Breakage

    Arthrex, Inc. is recalling specific Anthrex PEEK SwiveLock SP Vented anchors because some eyelets broke during insertion. The recall covers units distributed in the US and several international locations.

    Product
    Anthrex PEEK SwiveLock SP Vented, 5.5mm x 24.5 mm, Self-Punching
    Category
    Medical Device
    Distribution
    49 states
  • SevereFDA (Devices)·Z-2045-2017·2017-05-17

    Arthrex SpeedBridge Implant System Recalled for Broken Eyelets

    Arthrex is recalling specific SpeedBridge Implant Systems because some eyelets broke during insertion. The recall covers multiple batches distributed in the US and internationally.

    Product
    Anthrex SpeedBridge Implant System with BioComposite SwiveLock SP Vented, 5.5 mm x 24 mm
    Category
    Medical Device
    Distribution
    49 states
  • SevereFDA (Devices)·Z-2050-2017·2017-05-17

    Mederi Stretta Catheter Recalled Due to Sterility Compromise

    Mederi Therapeutics is recalling 1,458 Stretta Catheter kits because a breach in the sterile barrier package compromised sterility.

    Product
    Mederi Stretta Catheter and Accessory Kit, Sterile For Use with the MEDERI MDRF1 GENERATOR ONLY. Used in the treatment of gastroesophageal reflux disease (GERD). REF 175-5580
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2068-2017·2017-05-17

    Zimmer Biomet Recalls Regenerex Patella Implants Due to Peg Shearing

    Zimmer Biomet is recalling 8,154 Regenerex Series A Patella implants because the pegs may shear after surgery.

    Product
    Regenerex Patella RGX 3 PEG SER A PATELLA 28MM RGX 3 PEG SER A PATELLA 31MM RGX 3 PEG SER A PATELLA 34MM RGX 3 PEG SER A PATELLA 37MM Product Usage: The Regenerex Series A Patella can be used for any non-cemented resurfaced 3-peg patella application within the Vanguard…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2062-2017·2017-05-17

    Abbott Recalls Healon Medical Device Due to Glass Particle Risk

    Abbott Medical Optics is recalling Healon medical devices because certain lots may contain microscopic glass particles from manufacturing damage.

    Product
    Healon, Part No. 10290953, 10295210, 10200011, 10200012, 10201012, 10203012, 10213012, 10223012, 10290701, 10294751, 10295701
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2066-2017·2017-05-17

    Abbott Recalls Healon Pro Due to Possible Glass Particles

    Abbott Medical Optics is recalling Healon Pro ophthalmic solutions because manufacturing damage may have introduced microscopic glass particles.

    Product
    Healon Pro, Part No. 10270012
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2064-2017·2017-05-17

    Abbott Recalls Healon Duet Due to Potential Glass Particles

    Abbott Medical Optics is recalling Healon Duet units because they may contain microscopic glass particles from manufacturing damage.

    Product
    Healon Duet, Part No. 10290080, 10220010, 10220011 and 10220012
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2049-2017·2017-05-17

    Roche Diagnostics Recalls Sample Probes for Corrosion-Related Liquid Level Detection Issues

    Roche Diagnostics is recalling 3,946 sample probes for cobas analyzers because corrosion on electrical contacts can disrupt liquid level detection, potentially causing sample carryover.

    Product
    Sample probes associated with: cobas 6000 Series System, cobas 8000 Modular Analyzer Series, cobas c 311 analyzer cobas c 501/502 cobas c 701/702 cobas 8000 ISE Product Usage: The cobas 6000 series is a fully automated, random-access, software-controlled system for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2046-2017·2017-05-17

    Arthrex Recalls Anthrex SpeedBridge Implant System Due to Broken Eyelets

    Arthrex, Inc. is recalling the Anthrex SpeedBridge Implant System because some eyelets broke from the SwiveLock Anchor during insertion.

    Product
    Anthrex SpeedBridge Implant System with PEEK SwiveLock Self Punching
    Category
    Medical Device
    Distribution
    49 states
  • HighFDA (Devices)·Z-2063-2017·2017-05-17

    Abbott Recalls Healon GV Due to Possible Microscopic Glass Particles

    Abbott Medical Optics is recalling Healon GV due to a remote possibility of microscopic glass particles from manufacturing damage.

    Product
    Healon GV, Part No. 10294701, 10294801, 10200014, 10201014, 10202014, 10203014
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2065-2017·2017-05-17

    Abbott Recalls Healon 5 Pro Due to Possible Glass Particles

    Abbott Medical Optics is recalling Healon 5 Pro ophthalmic solution because some units may contain microscopic glass particles from manufacturing damage.

    Product
    Healon 5 Pro, Part No. 10270015
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2041-2017·2017-05-17

    Arthrex Bio-SwiveLock SP Vented Anchor Recall Due to Broken Eyelets

    Arthrex, Inc. is recalling specific Bio-SwiveLock SP Vented anchors because some eyelets broke during insertion.

    Product
    Anthrex Bio-SwiveLock SP Vented, 5.5mm x 24.5 mm, Self-Punching
    Category
    Medical Device
    Distribution
    49 states
  • HighFDA (Devices)·Z-2055-2017·2017-05-17

    Greatbatch Medical Recalls Linear Straight Broach Handles Due to Weld Breakage

    Greatbatch Medical is recalling specific Linear Straight Broach Handles because they may break at the welds or lose the locating pin during use.

    Product
    Linear Straight Broach Handle (Rasp Handle) (Greatbatch Part # 510397; DJO Surgical Inc., # 803-03-159) and EZ Clean" Linear Broach Handle Greatbatch Part # T11824, DJO Surgical Inc. # 803-03-059).
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2043-2017·2017-05-17

    Arthrex Bio Composite SwiveLock Anchor Eyelets Break on Insertion

    Arthrex is recalling specific batches of Bio Composite SwiveLock anchors because some eyelets broke during insertion.

    Product
    Anthrex Bio Composite SwiveLock SP Vented, 4.75 mm x 24.5 mm, Self-Punching
    Category
    Medical Device
    Distribution
    49 states
  • ModerateFDA (Devices)·Z-2056-2017·2017-05-17

    Zimmer Biomet Recalls Cobalt Bone Cement Due to Packaging Seal Issues

    Zimmer Biomet is recalling specific lots of Cobalt bone cement because a breach in the sterile Tyvek packaging could lead to loss of sterility.

    Product
    Cobalt HV Bone Cement Cobalt MV Bone Cement Cobalt HV Bone Cement With Gentamicin
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2040-2017·2017-05-17

    Siemens RAPIDPoint 500 Blood Gas Analyzer Recalled for Patient ID Error

    Siemens is recalling 159 RAPIDPoint 500 Blood Gas Analyzers because a blank patient ID field may cause demographic errors.

    Product
    RAPIDPoint¿ 500 Blood Gas Analyzer with v2.4 software for professional use in a point-of-care or laboratory environment. This system tests blood gases, electrolytes, metabolites, total hemoglobin, and hemoglobin derivatives in arterial, venous, and capillary whole blood samples.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2036-2017·2017-05-17

    Smith & Nephew Recalls Mislabelled Peri-Loc Volar Distal Radius Plates

    Smith & Nephew is recalling 12 units of Peri-Loc Volar Distal Radius plates that were laser-etched as left plates but packaged as right plates.

    Product
    PERI-LOC VOLAR DISTAL RADIUS - RIGHT 3H STD HEAD LOCKING PLATE, 62 MM LENGTH, SST PLATE, REF 71823114, QTY: (1) NON-STERILE, Rx only, Smith & nephew, Inc., Memphis TN 38116
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2047-2017·2017-05-17

    Medtronic PAK Needle Beveled and Trocar Tips Recalled for Packaging Error

    Medtronic is recalling 36 units of PAK Needle Beveled and Trocar Tips because packaging may contain incorrect needle types instead of the required combination.

    Product
    Medtronic PAK NEEDLE BEVELED AND TROCAR TIPS, REF 8670009, QTY 1 EA, STERILE R, Rx only
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-2059-2017·2017-05-17

    Zimmer Biomet Recalls Mislabeled Bone Dowell Harvest Tubes

    Zimmer Biomet is recalling 49 Bone Dowell Harvest Tubes that were mislabeled as 8mm but are actually 9mm in size.

    Product
    Bone Dowell Harvest Tubes
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2048-2017·2017-05-17

    Zimmer CAS Recalls NDI P7 Position Sensors for Potential Malfunction

    Zimmer CAS is recalling 34 NDI P7 Position Sensors due to a manufacturing issue that may cause them to stop functioning during use.

    Product
    NDI P7 Position Sensor, Stereotaxic Instrument
    Category
    Medical Device
    Distribution
    8 states