The Recall Desk
Agency classClass IIOur severity:SevereFDA (Devices)·Z-3266-2026·Announced 2026-09-30

Medline Neurological Sponges Recalled for Potential Endotoxin Variability

Medline Industries is recalling 128 Major Pack Convenience Kits containing neurological sponges due to potential endotoxin variability that may cause adverse health events.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 4/5 (Severe).

The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.

Our severity reasoning: The recall is classified as FDA Class II and involves potential health risks requiring medical intervention, such as neurovascular adverse events and hypotension, which aligns with the 'Severe' criteria for significant injury reports or high-risk medical device defects.

Plain-English summary

Medline Industries, LP is recalling 128 units of Medline Convenience Kits, specifically the Major Pack (Catalog Number DYNJ81325A). The affected products were distributed nationwide in the United States. The specific lot number is 23HBB258, with UDI-DI 10195327270360 for individual units and 40195327270361 for cases.

The recall is due to the potential for unexpected variability in endotoxin levels within the neurological sponges included in the kits. Potentially elevated endotoxin levels may present health risks that could require medical intervention. Reported or potential adverse effects include neurovascular adverse events, febrile response, local transient inflammation, hypotension, or nausea.

Healthcare facilities and consumers should check their inventory for the specific catalog number and lot number listed above. If the product is found, it should be removed from use and returned to Medline Industries, LP in accordance with their recall instructions.

The recalled product

Product
Medline Convenience Kits: 1) MAJOR PACK, Catalog Number: DYNJ81325A
Affected units
128

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (4)

  • 1) DYNJ81325A
  • UDI-DI: 10195327270360(each)
  • 40195327270361(case)
  • Lot Number: 23HBB258

Distribution

Distributed nationwide across the United States.

Same manufacturer · Medline Industries, LP

See all →