Cardinal Health Recalls Blue Impervious Gowns for Flammability Defect
Cardinal Health is recalling Blue Impervious Gowns, X-Large, because they failed to meet federal flammability standards for vinyl plastic film.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The recall involves a failure to meet federal flammability standards (16 CFR 1611), which presents a significant fire hazard. Per the rubric, significant injury or property damage risks associated with structural or safety defects warrant a Severe rating.
Plain-English summary
Cardinal Health is recalling approximately 4,062,511 units of Blue Impervious Gown with Thumbhooks, X-Large. These non-sterile, single-use plastic isolation gowns are intended to serve as a physical barrier to the transfer of microorganisms, body fluids, and particulate material.
The recall was initiated because the gowns do not meet design specifications, specifically 16 CFR 1611, the Standard for the Flammability of Vinyl Plastic Film. Testing revealed that the gowns failed in the machine direction with a flame propagation rate of 1.9-2.0 inches per second, exceeding the limit of 1.2 inches per second. The gowns passed testing in the cross direction by self-extinguishing.
The affected products were distributed nationwide to consignees in Alabama, Arkansas, Arizona, California, Connecticut, Florida, Georgia, Illinois, Indiana, Kentucky, Louisiana, Massachusetts, Maryland, Michigan, Missouri, North Carolina, New Jersey, New Mexico, Nevada, New York, Ohio, Pennsylvania, South Carolina, Texas, Utah, Virginia, Washington, and West Virginia. All lots with material numbers 5213PG and V5213PG are affected. Consumers and healthcare facilities should stop using these gowns and contact Cardinal Health for further instructions.
The recalled product
- Product
- BLUE IMPERVIOUS GOWN WITH THUMBHOOKS, X-LARGE. Non-Sterile, Single Use Only, Plastic Non-Surgical Isolation Gown Non-Sterile, Single Use Only, Plastic Non-Surgical Isolation Gown. Serves as physical barrier to the transfer of microorganisms, body fluids and particulate material.…
- Manufacturer
- Cardinal Health
- Category
- Medical Device — Isolation Gowns
- Hazard
- Affected units
- 4,062,511
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- All Lots with material number 5213PG and V5213PG
Distribution
Related recalls
Same manufacturer · Cardinal Health
See all →- HighDover Closed Urethral Tray Recalled for Potential Drainage Blockage Risk
FDA (Devices) · 2022-12-14
- HighDover Urethral Catheter Drainage System Recall for Potential Port Blockage
FDA (Devices) · 2022-12-14
- HighDover Urinary Catheter Drainage Tray Recall Due to Blockage Risk
FDA (Devices) · 2022-12-14
- HighDover Closed Urethral Tray Recalled Due to Drainage Port Blockage Risk
FDA (Devices) · 2022-12-14
- HighDover urinary catheter drainage bag occlusion defect nationwide recall
FDA (Devices) · 2022-12-14
Same hazard · fire
See all →- SevereVQQQ Gas Patio Heaters Recalled for Fire and Burn Hazards
CPSC · 2026-10-22
- HighAutocar Recalls Xpeditor Trucks for Fuel Hose Separation Risk
NHTSA · 2026-10-21
- SevereAudi Recalls 2024-2025 Q4 E-Tron Models Due to Battery Fire Risk
NHTSA · 2026-10-21
- HighForest River Recalls 2023-2026 Pause Travel Trailers for Wiring Defect
NHTSA · 2026-10-20
- SevereForest River Recalls 2026-2027 Cedar Creek Trailers for Fire Risk
NHTSA · 2026-10-16
Similar recalls
- ModerateCardinal Health Recalls Kendall Blue XXL Gowns Due to Defects
FDA (Devices) · 2021-02-17
- ModerateCardinal Health Recalls Kendall Blue Isolation Gowns Due to Defects
FDA (Devices) · 2021-02-17
- ModerateCardinal Health Recalls Lab Coats and Gowns Due to Defects
FDA (Devices) · 2021-02-17
- HighCardinal Health Recalls Isolation Gowns Due to Manufacturing Defects
FDA (Devices) · 2021-02-17
- ModerateCardinal Health Recalls Lab Coats and Gowns Due to Manufacturing Defects
FDA (Devices) · 2021-02-17
- ModerateCardinal Health Recalls Isolation Gowns Due to Potential Rips and Holes
FDA (Devices) · 2021-02-17