Medtronic Recalls Sherpa NX Active Guiding Catheters Due to Material Loss
Medtronic Vascular is recalling 143 units of Sherpa NX Active Guiding Catheters because primary segment material may be lost, exposing underlying stainless-steel braid wires.
The agency’s classification
FDA (Devices): Class I
Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The agency classification is FDA Class I, which mandates a minimum severity score of 4 per the rubric. Additionally, the exposure of stainless-steel braid wires in a cardiovascular device represents a significant structural defect with potential for serious injury.
Plain-English summary
Medtronic Vascular is recalling 143 units of the Sherpa NX Active Guiding Catheter, 6F EBU5.0, .070" (Reference SA6EBU50). The recall affects all lot and serial numbers for this specific product configuration.
The recall was initiated because there is a potential for extensive loss of primary segment material on a subset of these 6F Sherpa catheters. This defect may expose the underlying stainless-steel braid wires. The product is intended for cardiovascular use.
The affected units were distributed worldwide to the United States, Austria, Belgium, Bulgaria, Czech Republic, France, Germany, Greece, Hong Kong, Ireland, Italy, Kazakhstan, Luxembourg, Moldova, Netherlands, Poland, Portugal, Russian Federation, Saudi Arabia, Slovakia, South Africa, Spain, Sweden, Taiwan, and the United Kingdom. Healthcare providers and facilities should stop using the affected devices and contact Medtronic Vascular for instructions on return or replacement.
The recalled product
- Product
- SHERPA NX ACTIVE GUIDING CATHETER, 6F EBU5.0, .070", REF SA6EBU50. for cardiovascular use
- Manufacturer
- Medtronic Vascular
- Affected units
- 143
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- GTIN: 00613994824608 All Lot/Serial Numbers
Distribution
Distribution scope not specified by the agency.
Part of a larger recall action
This product is one of 191 recalled by Medtronic Vascular under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 191 products in this recall →Related recalls
Same manufacturer · Medtronic Vascular
See all →- SevereMedtronic Angiographic Guidewire Components Shipped Without Required Sterilization
FDA (Devices) · 2021-06-23
- SevereMedtronic Guide Catheter Recalled Due to Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- SevereMedtronic Guide Catheter Recalled Due to Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- HighMedtronic 6F Launcher Guide Catheter Recalled for Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- SevereMedtronic Guide Catheter Recalled for Potential Sterility Compromise
FDA (Devices) · 2021-03-17
Same hazard · structural defect
See all →- SevereToyota Recalls Sienna Hybrid Vehicles Due to Second-Row Seat Back Defect
NHTSA · 2026-10-20
- SevereSubaru Recalls 2026 Forester and Crosstrek for Ball Joint Defect
NHTSA · 2026-10-19
- Severe
- SevereVolvo Recalls 2025-2026 VNL Trucks for Loose Structural Bolts
NHTSA · 2026-10-15
- Severe
Similar recalls
- SevereMedtronic Guide Catheter Recalled Due to Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- SevereMedtronic Guide Catheter Recalled for Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- SevereMedtronic Recalls 6F Taiga Guiding Catheters Due to Tip Detachment
FDA (Devices) · 2018-04-04
- HighMedtronic Archer Super Stiff Guidewire Recalled for Coating Separation Risk
FDA (Devices) · 2013-04-03
- HighCodman NeuroPath Guiding Catheter Recalled for Potential Sterility Compromise
FDA (Devices) · 2013-02-27
- SevereCodman & Shurtleff Recalls Neuropath Guiding Catheters Due to Sterility Concerns
FDA (Devices) · 2013-02-27