Medtronic Recalls Sherpa NX Active Guiding Catheters for Material Loss
Medtronic Vascular is recalling 531 units of Sherpa NX Active Guiding Catheters due to potential loss of primary segment material exposing underlying stainless-steel braid wires.
The agency’s classification
FDA (Devices): Class I
Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The agency classification is FDA Class I, which mandates a minimum severity score of 4 according to the rubric.
Plain-English summary
Medtronic Vascular is recalling 531 units of the Sherpa NX Active Guiding Catheter, 6F SL4.0, .070" (Reference SA6SL40). The recall affects all lot and serial numbers for this specific product configuration. The device is intended for cardiovascular use.
The recall is being issued because there is a potential for extensive loss of primary segment material on a subset of the 6F Sherpa catheters. This defect may expose the underlying stainless-steel braid wires. The agency has classified this recall as Class I.
The affected products were distributed worldwide to the United States, Austria, Belgium, Bulgaria, the Czech Republic, France, Germany, Greece, Hong Kong, Ireland, Italy, Kazakhstan, Luxembourg, Moldova, the Netherlands, Poland, Portugal, the Russian Federation, Saudi Arabia, Slovakia, South Africa, Spain, Sweden, Taiwan, and the United Kingdom. Healthcare professionals should stop using the affected devices and contact Medtronic Vascular for further instructions.
The recalled product
- Product
- SHERPA NX ACTIVE GUIDING CATHETER, 6F SL4.0, .070", REF SA6SL40. for cardiovascular use
- Manufacturer
- Medtronic Vascular
- Affected units
- 531
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- GTIN: 00613994822499 All Lot/Serial Numbers
Distribution
Distribution scope not specified by the agency.
Part of a larger recall action
This product is one of 191 recalled by Medtronic Vascular under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 191 products in this recall →Related recalls
Same manufacturer · Medtronic Vascular
See all →- SevereMedtronic Angiographic Guidewire Components Shipped Without Required Sterilization
FDA (Devices) · 2021-06-23
- SevereMedtronic Guide Catheter Recalled Due to Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- SevereMedtronic Guide Catheter Recalled Due to Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- HighMedtronic 6F Launcher Guide Catheter Recalled for Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- SevereMedtronic Guide Catheter Recalled for Potential Sterility Compromise
FDA (Devices) · 2021-03-17
Same hazard · material loss
See all →- SevereMedtronic Recalls Sherpa NX Active Guiding Catheters Due to Material Loss
FDA (Devices) · 2019-10-09
- SevereMedtronic Recalls Sherpa NX Active Guiding Catheters Due to Material Loss
FDA (Devices) · 2019-10-09
- SevereMedtronic Recalls Sherpa NX Active Guiding Catheters Due to Material Loss
FDA (Devices) · 2019-10-09
- SevereMedtronic Recalls Sherpa NX Active Guiding Catheters Due to Material Loss
FDA (Devices) · 2019-10-09
- SevereMedtronic Vascular Recalls Sherpa NX Active Guiding Catheters
FDA (Devices) · 2019-10-09
Similar recalls
- SevereMedtronic Guide Catheter Recalled Due to Potential Sterility Compromise
FDA (Devices) · 2021-03-17
- SevereCodman & Shurtleff Recalls Neuropath Guiding Catheters Due to Sterility Concerns
FDA (Devices) · 2013-02-27
- HighCodman NeuroPath Guiding Catheter Recalled for Potential Sterility Compromise
FDA (Devices) · 2013-02-27
- HighCodman NeuroPath Guiding Catheters Recalled for Potential Sterility Compromise
FDA (Devices) · 2013-02-27
- SevereMedtronic Recalls 6F Taiga Guiding Catheters Due to Tip Detachment
FDA (Devices) · 2018-04-04
- SevereStryker Neurovascular Recalls Guider Softip XF Guide Catheters
FDA (Devices) · 2016-11-09