Biomerieux Recalls VITEK 2 Gram Positive Susceptibility Cards
Biomerieux Inc is recalling VITEK 2 Gram Positive Susceptibility cards because compromised container integrity may expose the product to moisture, leading to antibiotic degradation and loss of potency.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 2/5 (Moderate).
Minor labeling or packaging issue, or a voluntary precautionary recall. Risk of harm is low but real — follow the manufacturer's instructions.
Our severity reasoning: The recall is classified as FDA Class II, but the source text does not report any hospitalizations, injuries, or illnesses. The hazard is a theoretical loss of potency due to moisture exposure, which aligns with the criteria for a moderate severity score involving low-risk contamination or voluntary precautionary recalls without reported harm.
Plain-English summary
Biomerieux Inc is voluntarily recalling 2,260 cartons of VITEK 2 Gram Positive Susceptibility cards (AST-P616), REF 410223. The recall was initiated because the integrity of the product container may be compromised, which could expose the product to moisture. This exposure may lead to antibiotic degradation and a loss of potency.
The affected product was distributed nationwide in the United States, including to military and government sites. The product was also distributed to numerous international locations, including Algeria, Angola, Argentina, Australia, Austria, Bahrain, Bangladesh, Belarus, Belgium, Bosnia - Herzegovina, Brazil, Brunei, Bulgaria, Burkina Faso, Cambodia, Cameroun, Canada, Chad, Chile, China, Colombia, Congo, Costa Rica, Croatia, Czech Republic, Denmark, Dominican Republic, Dutch Antilles, Ecuador, Egypt, El Salvador, Estonia, Finland, France, Gabon, Gambia, Georgia, Germany, Greece, Grenada, Guatemala, Guinea, Haiti, Honduras, Hungary, India, Indonesia, Iraq, Israel, Italy, Ivory Coast, Japan, Jordan, Kazakhstan, Kenya, Uganda, Kuwait, Laos, Latvia, Lebanon, Lithuania, Malaysia, Mali, Malta, Mexico, Mongolia, Morocco, Mozambique, Myanmar, Netherlands, Nigeria, Norway, Oman, Pakistan, Palestine, Panama, Paraguay, Peru, Philippines, Poland, Portugal, Romania, Russia, Saudi Arabia, Senegal, Serbia, Singapore, Slovenia, South Africa, South Korea, Spain, Sri Lanka, Sweden, Switzerland, Syria, Thailand, Tunisia, Turkey, Ukraine, United Arab Emirates, United Kingdom, Uruguay, Venezuela, Vietnam, and Zimbabwe.
Healthcare facilities and consumers should stop using the affected product and contact Biomerieux Inc for further instructions or a refund. The recall number is Z-2373-2017.
The recalled product
- Product
- VITEK¿ 2 Gram Positive Susceptibility card (AST-P616), REF 410223, 20 cards per carton.
- Manufacturer
- Biomerieux Inc
- Affected units
- 2,260
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- 4960178203 23/May/18
Distribution
Part of a larger recall action
This product is one of 187 recalled by Biomerieux Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 187 products in this recall →Related recalls
Same manufacturer · Biomerieux Inc
See all →- HighBiomerieux VITEK 2 AST-N461 Test Kit Recalled for Card Pouch Damage
FDA (Devices) · 2026-09-30
- HighVITEK 2 AST-N447 Test Kit Potentially Returns False Resistant Results
FDA (Devices) · 2026-07-15
- HighSusceptibility test cards recalled over false resistant antibiotic results
FDA (Devices) · 2026-02-11
- HighAntimicrobial susceptibility test cards recalled over false colistin resistance results
FDA (Devices) · 2025-10-08
- SevereVITEK 2 AST Test Kits: Ceftriaxone Concentration Error Risk
FDA (Devices) · 2024-05-01
Same hazard · loss of potency
See all →- ModerateInfuvite Adult Multiple Vitamins Injection Recalled Due to Cold Chain Failure
FDA (Drugs) · 2025-05-07
- ModerateCardinal Health Recalls Cyanocobalamin Injection Due to Temperature Excursions
FDA (Drugs) · 2021-06-02
- ModerateSmiths Medical Recalls Arterial Blood Sampling Kits with Povidone Iodine Pads
FDA (Devices) · 2019-02-27
- ModerateBiomerieux Recalls VITEK 2 Gram Negative Susceptibility Cards Due to Moisture Risk
FDA (Devices) · 2017-06-21
- ModerateBiomerieux Recalls VITEK 2 Gram Negative Susceptibility Cards
FDA (Devices) · 2017-06-21
Similar recalls
- HighbioMerieux Recalls VITEK 2 Gram Positive Susceptibility Test Cards
FDA (Devices) · 2016-05-11
- ModerateBiomerieux Recalls VITEK 2 Gram-positive Susceptibility Cards Due to False Positives
FDA (Devices) · 2020-04-29
- SevereBiomerieux Recalls Vitek 2 Gram Positive Susceptibility Test Cards for Labeling Error
FDA (Devices) · 2016-05-18
- LowBiomerieux Recalls Vitek 2 Gram Positive Susceptibility Cards Due to Labeling Error
FDA (Devices) · 2015-04-15
- SevereBiomerieux Vitek 2 Gram Positive Test Cards Recalled for Labeling Error
FDA (Devices) · 2016-05-18
- LowBiomerieux Recalls Vitek 2 AST-P641 Cards Due to Labeling Error
FDA (Devices) · 2015-04-15