The Recall Desk
Agency classClass IOur severity:SevereFDA (Devices)·Z-2307-2014·Announced 2014-09-10

Customed Recalls Laparotomy Packs Due to Potential Packaging Integrity Issues

Customed, Inc. is recalling 32 lots of Laparotomy Packs because packaging integrity may be compromised, potentially leading to product contamination or loss of sterility.

The agency’s classification

FDA (Devices): Class I

Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 4/5 (Severe).

The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.

Our severity reasoning: The agency classified this recall as Class I — a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. On that classification alone this is scored Severe; a score of Critical is reserved for recalls where a death or serious injury was reported. The agency gives the reason as: "Customed has determined that there is the possibility that packaging integrity may be compromised on different catalog numbers (multiple lots). This could result in an injury to the patient due to product contamination or loss of sterility…"

Plain-English summary

Customed, Inc. is recalling 32 lots of Customed Laparotomy Packs, which are convenience packs containing multiple surgical components such as drapes, gowns, towels, sponges, and surgical solutions. The recall involves 8,954 units distributed worldwide, including the United States (nationwide, specifically Florida, Puerto Rico, and USVI) and several international locations such as Tortola, Trinidad, Dominican Republic, Costa Rica, and Mexico.

The recall was initiated because Customed determined that there is a possibility that the packaging integrity of the products may be compromised. This defect could result in product contamination or a loss of the sterile condition, which poses a risk of injury to patients using the equipment during surgical procedures.

The affected product code is 900-149. The specific lot numbers involved in this recall are: 111113165, 111123349, 112010052, 112010280, 112030621, 112041077, 112051768, 112062421, 112083062, 112093900, 112104147, 112114637, 112114952, 113015429, 113025941, 113026204, 113036749, 113047333, 113057861, 113078258, 113078600, 113089192, 113109733, 131110083, 131110399, 131110578, 131210961, 140111409, 140211872, 140312328, 140412830, and 140513345. Healthcare facilities and distributors should check their inventory for these specific lot numbers and stop using the affected products.

The recalled product

Product
Customed Laparotomy Pack , convenience pack include multiple components: drape laparot., gown, absorbent towel, scrub, stck sponges/ gauzes, table cover, drape sheet, suture bag, duraprep surgical solution, cloth huck towels, utility bowls, suction tube, scalpel, Mayo Tray, Mayo…
Manufacturer
Customed, Inc

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (1)

  • Product code 900-149

Distribution

Distributed nationwide across the United States.

The notice also names 2 states specifically:

Part of a larger recall action

This product is one of 233 recalled by Customed, Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 233 products in this recall →