DePuy Recalls Luster Hip Stems Implanted with Metal-on-Metal Articulations
DePuy Orthopaedics is issuing a Field Safety Notice for Luster and Ultima LX hip stems implanted with metal-on-metal articulations.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The recall is classified as FDA Class II and involves a structural defect in a medical device (metal-on-metal articulation) that poses a significant risk of injury.
Plain-English summary
DePuy Orthopaedics, Inc. is issuing a Field Safety Notice for Luster Cemented Polished Femoral Hip Stems and Ultima LX Cemented Polished Femoral Hip Stems. This notice applies to these specific stems when they were implanted with any metal-on-metal (MoM) articulation, including configurations with a cobalt-chromium (CoCr) head and an all-metal acetabular cup (monoblock or modular).
The Luster Cemented Polished Femoral Hip Stems are forged CoCr polished cemented stems used as part of a total hip arthroplasty. They were indicated for use with all DePuy bearings and acetabular cups. The recall involves 85 Luster Cemented Polished Femoral Hip Stems across 69 lots, with product code 152180009 and specific lot numbers including AE9GG1000, AH7DW1000, U5TA2C000, V1YEE1001, W1CBL1001, W5RF41001, W5RF41007, and Y84DW1000.
The products were distributed nationwide, including in California, Colorado, Iowa, North Carolina, Ohio, Texas, Washington, Wisconsin, and West Virginia. Patients who have had these specific hip stems implanted with metal-on-metal articulations should contact their healthcare provider for guidance.
The recalled product
- Product
- LUSTER HIP SZ 9 Packaging: The product was packaged within inner and outer blister trays, sealed with coated Tyvek lidding. The stems were packaged within vinyl protectors, with foam taper protectors. Intended Use: The LUSTER Cemented Polished Femoral Hip Stems product are…
- Manufacturer
- DePuy Orthopaedics, Inc.
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (8)
- Product code:152180009 and Lot numbers: AE9GG1000
- AH7DW1000
- U5TA2C000
- V1YEE1001
- W1CBL1001
- W5RF41001
- W5RF41007
- and Y84DW1000.
Distribution
Part of a larger recall action
This product is one of 19 recalled by DePuy Orthopaedics, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 19 products in this recall →Related recalls
Same manufacturer · DePuy Orthopaedics, Inc.
See all →- HighATTUNE AFFIXIUM Knee Implant Component Recalled for Incorrect Labeling
FDA (Devices) · 2024-04-10
- HighAttune Revision Tibial Insert Recalled for Excessive Gamma Radiation Exposure
FDA (Devices) · 2023-03-29
- HighDePuy Attune Tibial Insert Recalled for Excessive Radiation Exposure
FDA (Devices) · 2023-03-29
- HighOrthopedic Implant Recall: Excessive Radiation Exposure in Revision Tibial Insert
FDA (Devices) · 2023-03-29
- HighOrthopedic Tibial Insert Recalled Due to Excessive Radiation Exposure
FDA (Devices) · 2023-03-29
Same hazard · metal on metal wear
See all →- HighDePuy Recalls Luster and Ultima Hip Stems Implanted with Metal-on-Metal Components
FDA (Devices) · 2012-07-11
- HighDePuy Orthopaedics Recalls ULTIMA LX and LUSTER Hip Stems
FDA (Devices) · 2012-07-11
Similar recalls
- HighDePuy Solution Calcar Stems Recalled Due to Potential Impingement
FDA (Devices) · 2012-12-26
- HighDePuy Solution Calcar Stem Recalled for Potential Impingement
FDA (Devices) · 2012-12-26
- HighDePuy Orthopaedics Recalls Solution Calcar Stems Due to Impingement Risk
FDA (Devices) · 2012-12-26
- HighDePuy Solution Calcar Stems Recalled for Potential Impingement
FDA (Devices) · 2012-12-26
- ModerateZimmer Recalls CPT Femoral Stems Due to Packaging Adhesion Issue
FDA (Devices) · 2013-11-06
- HighDePuy Ceramic Femoral Head Recalled for Fit Issues in Hip Surgery
FDA (Devices) · 2014-12-24