PerkinElmer Specimen Gate Screening Center Software Recall for Data Errors
PerkinElmer is recalling Specimen Gate Screening Center software due to potential errors in neonatal screening results, including false negatives and positives.
What this means for you
Illness, injury, or structural failure has been reported. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The agency classified this as an FDA Class II recall. Per the rubric, FDA Class II recalls are assigned a severity score of 4 (Severe), particularly when involving significant risks to patient data integrity in medical screening.
Plain-English summary
PerkinElmer Life and Analytical Sciences, Wallac, OY is recalling the Specimen Gate Screening Center, Part Number 5002-0500. The recall covers all software versions from 1.0 to 1.8, which is the current version. This software is used by qualified laboratory personnel in newborn screening programs to manage data for neonatal screening test results and demographics.
The recall was initiated because the product may generate potential errors in patient results. These errors include both false negative and false positive results. The agency has classified this as a Class II recall.
The product was distributed worldwide, including in the United States (specifically the state of Georgia) and in Belgium, Canada, Denmark, Italy, and the United Kingdom. A total of 8 units are affected. Consumers and laboratory personnel should contact the recalling firm for further instructions on how to address the software errors.
The recalled product
- Product
- Specimen Gate Screening Center, Part Number 5002-0500, All software versions from 1.0 to 1.8 (current software version) Specimen Gate Screening Center is used for data management of neonatal screening test results and demographics by qualified laboratory personnel in newborn s
- Category
- Medical Device — Software
- Affected units
- 8
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- All software versions from 1.0 to 1.8 (current software version)
Distribution
Distributed in 1 state:
Related recalls
Same manufacturer · PerkinElmer Life and Analytical Sciences, Wallac, OY
See all →- ModeratePerkinElmer Recalls DELFIA hCG Kits Due to Measurement Inaccuracy
FDA (Devices) · 2019-05-08
- ModeratePerkinElmer AutoDELFIA hCG Kit Recalled for Inaccurate Low-Range Results
FDA (Devices) · 2019-05-08
- ModeratePerkinElmer AutoDELFIA hCG Kit Recalled for Potential Measurement Inaccuracy
FDA (Devices) · 2019-05-08
- LowAutoDELFIA Neonatal IRT Kit Recalled for Missing Quality Control Certificate Information
FDA (Devices) · 2018-09-12
- ModeratePerkinElmer Recalls NeoBase Succinylacetone Assay Solution Due to Leaking Vials
FDA (Devices) · 2018-05-16
Same hazard · data error
See all →- HighBar Code Reader Wands for GEM Premier Blood Analyzers Recalled Due to Misidentification Risk
FDA (Devices) · 2026-08-05
- ModerateBiomet 3i Recalls Bellatek Encode Healing Abutments Due to Data Errors
FDA (Devices) · 2020-03-04
- HighBiomet 3i Recalls Bellatek Encode Healing Abutments Due to Data Errors
FDA (Devices) · 2020-03-04
- SeverePerkinElmer Recalls Specimen Gate Laboratory Software Due to Data Errors
FDA (Devices) · 2017-04-19
- ModerateHitachi Echelon MRI System Recalled for Image Data Transfer Errors
FDA (Devices) · 2017-03-29