Flexicare ProVu Video Stylet Recalled for Potential Airway Occlusion
Flexicare Medical Ltd. is recalling ProVu Single Use Video Stylets with ET Tubes because over-inflated cuffs may block the airway, making it difficult to ventilate patients.
The agency’s classification
FDA (Devices): Class I
Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The agency classified this recall as Class I — a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. On that classification alone this is scored Severe; a score of Critical is reserved for recalls where a death or serious injury was reported. The agency gives the reason as: "When the video stylet cuff is over-inflated there is potential for occlusion of the corrugated section of the ETT, and increased resistance to gas flow and difficulty in ventilating the patient."
Plain-English summary
Flexicare Medical Ltd. is recalling 2,087 units of ProVu Single Use Video Stylets with Endotracheal (ET) Tubes. The affected products are distributed nationwide in the United States and include specific part and lot numbers for sizes 6.5, 7.0, 7.5, and 8.0.
The recall is due to a potential safety issue where the video stylet cuff may be over-inflated. If this occurs, it can cause occlusion of the corrugated section of the ET tube, leading to increased resistance to gas flow and difficulty in ventilating the patient.
Healthcare providers and facilities should stop using the affected devices and contact Flexicare Medical Ltd. for instructions on return or replacement. The product list and lot numbers were updated per a letter to customers dated December 23, 2020.
The recalled product
- Product
- ProVu Single Use Video Stylet with ET Tube, Part/Size: 038-990-080U/ 8.0, 038-990-075U/ 7.5, 038-990-070U/ 7.0, 038-990-065U/ 6.5 *Note: product list updated per 12/23/2020 letter to customers
- Manufacturer
- Flexicare Medical Ltd.
- Affected units
- 2,087
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- Part/ Lot: 038-990-080U/ 191102901
- 200300486
- 200300539
- 200500068
- 200500069
- 200803210
- 191201567
- 200904316
- 200904319
- 038-990-075U/ 191102900
- 200100157
- 200300535
- 200300536
- 200300537
- 200402330
- 200402331
- 200402333
- 200402334
- 200402335
- 200402336
Distribution
Distributed nationwide across the United States.
Related recalls
Same manufacturer · Flexicare Medical Ltd.
See all →- HighFlexicare BriteBlade Pro Laryngoscope Blades Recalled for Loose Components
FDA (Devices) · 2020-01-22
- HighFlexicare BriteBlade Pro Laryngoscope Blades Recalled for Loose Components
FDA (Devices) · 2020-01-22
- HighFlexicare BriteBlade Pro Laryngoscope Blades Recalled for Loose Components
FDA (Devices) · 2020-01-22
- HighFlexicare BriteBlade Pro Laryngoscope Blades Recalled for Loose Components
FDA (Devices) · 2020-01-22
Same hazard · airway occlusion
See all →- HighIntersurgical Recalls One-Piece Guedel Airway Devices Due to Occlusion Risk
FDA (Devices) · 2026-08-26
- HighIntersurgical Recalls One-Piece Guedel Airway Devices Due to Occlusion Risk
FDA (Devices) · 2026-08-26
- HighIntegrated Medcraft Recalls First Aid Kits with Defective Airway Tips
FDA (Devices) · 2026-08-12
- HighAtos Medical Recalls Provox Life Night HME Devices Due to Insertion Risk
FDA (Devices) · 2021-05-19
- HighIntersurgical Solus Flexible Laryngeal Mask Airways Recalled for Occlusion Risk
FDA (Devices) · 2017-12-13
Similar recalls
- SevereFlexi-Set Endotracheal Tubes recalled for connector disconnection risk
FDA (Devices) · 2023-07-05
- SevereFlexi-Set Uncuffed Endotracheal Tubes recalled for connector disconnection risk
FDA (Devices) · 2023-07-05
- SevereFlexi-Set Endotracheal Tube Recalled for Connector Disconnection
FDA (Devices) · 2023-07-05
- SevereFlexi-Set Endotracheal Tubes Recalled Due to Connector Disconnection Risk
FDA (Devices) · 2023-07-05
- SevereFlexi-Set Endotracheal Tube Connectors Recalled Due to Disconnection Risk
FDA (Devices) · 2023-07-05
- SevereFlexi-Set Endotracheal Tubes Recalled for 15mm Connector Disconnection
FDA (Devices) · 2023-07-05