AB ULAX 1500 Flex Heat and Moisture Exchanger Recall for Disconnection Risk
AB ULAX is recalling 1500 Flex Heat and Moisture Exchangers because they may disconnect from the respiratory circuit, potentially causing hypoxia or death.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The source text explicitly states that the defect can potentially result in hypoxia or death, which aligns with the rubric criteria for a Severe (4) rating involving significant injury or death reports.
Plain-English summary
AB ULAX is recalling approximately 1,484,100 units of the 1500 Flex Heat and Moisture Exchanger (Catalog Reference 150). These devices are used to enhance humidification for ventilator-dependent and non-ventilator-dependent patients in critical care, home care, and anesthesia settings.
The recall was initiated after the firm received six complaints that the Heat Moisture Exchanger (HME) disconnected from the closed respiratory circuit during use. If the HME separates, the ventilator circuit may not provide adequate ventilation to the patient, potentially resulting in a lack of oxygen leading to hypoxia or death.
The affected units were distributed worldwide, including nationwide in the United States and in Sweden, Taiwan, Hong Kong, and Spain. The recall covers specific lots manufactured between September 2018 and June 2020, identified by SAP codes 109381602 and 109381603. Users should check their device lot numbers against the recall list and contact AB ULAX for instructions on replacement or return.
The recalled product
- Product
- 1500 Flex Heat and Moisture Exchanger, Catalog Reference 150 - Product Usage: Heat Moisture Exchangers (HM Es) are designed to enhance humification of ventilator-dependent and non-ventilator dependent patients in critical care, home care and anesthesia.
- Manufacturer
- AB ULAX
- Affected units
- 1,484,100
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (2)
- SAP 109381602
- Lots 2019-12-20 2020-04-30 2020-05-15 2020-05-20 2020-06-15 2020-06-30
Distribution
Distributed nationwide across the United States.
Related recalls
Same hazard · hypoxia
See all →- SevereCardinal Health Recalls Presource Packs with Medtronic Microstream Components
FDA (Devices) · 2026-10-14
- SevereGiraffe and Panda warmer blender knobs may deliver wrong oxygen concentration
FDA (Devices) · 2026-06-24
- SeverePanda freestanding warmer blender knobs may deliver wrong oxygen concentration
FDA (Devices) · 2026-06-24
- SevereGiraffe infant resuscitation system may deliver wrong oxygen concentration
FDA (Devices) · 2026-06-24
- HighOxygen masks recalled after complaints of tubing disconnecting during use
FDA (Devices) · 2026-01-14
Similar recalls
- HighHME for Tracheostomized Patients Recalled Due to Sterilization Process Deviations
FDA (Devices) · 2021-06-23
- CriticalTeleflex Recalls MAQUET SERVO Humidifiers Due to Cracked Flex Tubes
FDA (Devices) · 2015-02-18
- SevereTeleflex Recalls MAQUET Servo Humidifier 163 Due to Connector Cracks
FDA (Devices) · 2015-02-18
- CriticalTeleflex Medical Recalls Hudson RCI Comfort Flo Humidification Systems
FDA (Devices) · 2020-02-19
- HighTeleflex Servo Humidifier 163 Recalled Due to Connector Cracks
FDA (Devices) · 2016-08-17
- High