The Recall Desk
Agency classClass IIOur severity:HighFDA (Devices)·Z-0010-2021·Announced 2020-10-07

Riverpoint Medical Recalls Non-Sterile Velosorb Surgical Sutures

Riverpoint Medical is recalling 7,969 units of Velosorb Fast Braided Absorbable Sutures because they are non-sterile, posing a risk of surgical site infection.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 3/5 (High).

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

Our severity reasoning: The recall involves a medical device that is non-sterile, creating a risk of surgical site infection. Per the rubric, this is classified as High (3) because it is a risk-of-harm product where injury has not yet been reported.

Plain-English summary

Riverpoint Medical, LLC is recalling 7,969 units of Velosorb Fast Braided Absorbable Sutures, specifically the 6/0 Undyed 18" P-10 Cutting variety (Product Number: SV9913, UDI: 20884521153278). The affected lot number is 20050709FX. These sutures were distributed nationwide in the United States.

The recall was initiated because the surgical sutures are non-sterile. The use of non-sterile sutures could compromise the sterile field during surgery, increase the risk of a surgical site infection, and affect break strength retention. The product is indicated for soft tissue approximation of the skin and mucosa where 7-10 days of wound support is required, but is not for use in ligation, ophthalmic, cardiovascular, or neurological procedures.

Healthcare facilities and consumers should stop using the affected sutures immediately. Riverpoint Medical is the recalling firm responsible for managing this Class II recall.

The recalled product

Product
Velosorb Fast Braided Absorbable Suture: Covidien Velosorb 6/0 Undyed 18" P-10 Cutting, Product Number: SV9913, UDI: 20884521153278 - Product Usage: indicated for use in soft tissue approximation of the skin and mucosa, where only 7-10 days of wound support is required, but not…
Affected units
7,969

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (1)

  • Lot Number: 20050709FX

Distribution

Distributed nationwide across the United States.

Part of a larger recall action

This product is one of 40 recalled by Riverpoint Medical, LLC under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 40 products in this recall →

Similar recalls