The Recall Desk

Manufacturer

ZOLL Medical Corporation

15 recalls in our database name ZOLL Medical Corporation as the manufacturing or recalling firm.

What the numbers show

Total
15
Critical
0
Severe
2
Most recent
2025-03-19

Of the 15 recalls from ZOLL Medical Corporation we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2 (13%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–15 of 15

  • HighFDA (Devices)·Z-1322-2025·2025-03-19

    ZOLL Powerheart G5 AED Self-Test May Fail Under Extreme Environmental Conditions

    ZOLL is recalling certain Powerheart G5 AED units that may fail their self-test when exposed to extreme temperatures or humidity. The affected devices could fail to function properly in emergencies.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: (1) G5S-00A-TSO, (2) G5S-01A, (3) G5S-02A, (4) G5S-05A, (5) G5S-08A, (6) G5S-10A, (7) G5S-11A, (8) G5S-80A-TSO, (9) G5S-80-L (10) G5S-90A; Software Version: NA Product Description: The Powerheart G5…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1318-2025·2025-03-19

    ZOLL Powerheart G5 AED may fail self-test in extreme environments

    ZOLL is recalling certain Powerheart G5 automated external defibrillators (AED) due to the potential for devices to fail their self-test when exposed to extreme temperatures or humidity.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: (1) G5A-80C, (2) G5A-80C-TSO. Software Version: NA Product Description: The Powerheart G5 automated external defibrillator (AED) is designed for treating life-threatening heart beat irregularities, such…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1316-2025·2025-03-19

    ZOLL Powerheart G5 AED May Fail Self-Test in Extreme Conditions

    The ZOLL Powerheart G5 automated external defibrillator may fail its self-test after prolonged exposure to extreme temperatures or humidity levels. This could prevent proper device functioning in an emergency.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: (1) G5A-00A, (2) G5A-01A, (3) G5A-02A, (4) G5A-03A, (5) G5A-19A, (6) G5A-80A, (7) G5A-80A-TSO. Software Version: NA Product Description: The Powerheart G5 automated external defibrillator (AED) is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1317-2025·2025-03-19

    ZOLL Powerheart G5 AED May Fail Self-Test After Environmental Exposure

    ZOLL Powerheart G5 AED devices may fail their self-test if exposed to extreme temperatures or humidity. Approximately 56,981 units are being recalled nationwide and internationally.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: (1) G5A-80A, (2) G5A-80A-TSO. Software Version: NA Product Description: The Powerheart G5 automated external defibrillator (AED) is designed for treating life-threatening heart beat irregularities, such…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1323-2025·2025-03-19

    ZOLL Powerheart G5 AED Devices Recalled for Self-Test Failure Risk

    ZOLL is recalling 8,744 Powerheart G5 AED units that may fail their self-test if exposed to extreme temperatures or humidity, potentially masking device malfunctions.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: G5S-80A; Software Version: NA Product Description: The Powerheart G5 automated external defibrillator (AED) is designed for treating life-threatening heart beat irregularities, such as ventricular…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1321-2025·2025-03-19

    ZOLL Powerheart G5 AED devices may fail self-test in extreme environments

    ZOLL is recalling Powerheart G5 AED devices that may fail their self-test when exposed to extreme temperature or humidity, potentially affecting proper device operation.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: G5S-80C; Software Version: NA Product Description: The Powerheart G5 automated external defibrillator (AED) is designed for treating life-threatening heart beat irregularities, such as ventricular…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1320-2025·2025-03-19

    ZOLL Powerheart G5 AED may fail self-test in extreme temperatures or humidity

    ZOLL is recalling 73 Powerheart G5 AED units that may fail their internal self-test when exposed to extreme temperatures or humidity. Affected devices could be unreliable in emergencies.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: (1) G5S-01C, (2) G5S-02C, (3) G5S-10C, (4) G5S-11C; Software Version: NA Product Description: The Powerheart G5 automated external defibrillator (AED) is designed for treating life-threatening heart beat…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1319-2025·2025-03-19

    ZOLL Powerheart G5 AED May Fail Self-Test in Extreme Environmental Conditions

    ZOLL is recalling certain Powerheart G5 AED models that may fail their self-test function when exposed to extreme temperature or humidity. Affected devices might not function properly in emergencies.

    Product
    Brand Name: ZOLL Product Name: Powerheart G5 AED Model/Catalog Number: (1) G5A-01C, (2) G5A-02C, (3) G5A-05C, (4) G5A-08C, (5) G5A-10C, (6) G5A-13C, (7) G5A-15C, (8) G5A-22C, (9) G5A-41C, (10) G5A-85C, (11) G5A-90C (12) G5A-80-L; Software Version: NA Product Description: The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2324-2024·2024-07-17

    ZOLL Powerheart G5 AED shipping film may prevent shock delivery

    ZOLL Powerheart G5 AED devices are shipped with a protective film on the front panel. If not removed before use, the film may prevent the shock button from being pressed, delaying or preventing defibrillation therapy.

    Product
    ZOLL Powerheart G5 AED, Semi-Automatic, G5Sxxx Family -Automated external defibrillator (AED) is designed for treating life-threatening heart beat irregularities, such as ventricular fibrillation, that cause Sudden Cardiac Arrest (SCA). Model/Catalog Number: G5S-00A…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2130-2024·2024-06-26

    Ventilator Operator's Guide Recalled for Missing Critical MRI Safety Information

    ZOLL is recalling operator's guides for the ZOLL 731 Ventilator because they omit critical MRI safety information. Missing distance guidance could cause the ventilator to malfunction during MRI procedures.

    Product
    ZOLL 731 Ventilator (EMV+, AEV, Eagle II) - for MRI Compatible Devices - Operator's Guide and Quick Reference Guide (QRGs) as follows: Part Numbers: 1. 799-EGL2-02 2. 799-EGL2-02-01 3. 799-EGL2-02-04 4. 799-EGL2-02-05 5. 799-EGL2-02-08 6. 799-EGL2-02-10 7.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1931-2019·2019-07-10

    ZOLL AED PRO Defibrillators Recalled for Potential Energy Delivery Failure

    ZOLL Medical Corporation is recalling 1,969 AED PRO units because they may fail to deliver energy to patients during cardiac arrest.

    Product
    ZOLL AED PRO Automated External Defibrillator Product Usage: The AED PRO unit is intended to defibrillate victims of ventricular fibrillation or pulseless ventricular tachycardia, for ECG monitoring, and for CPR monitoring of patients. The CPR monitoring function provides a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0977-2018·2018-03-21

    ZOLL Adult Defibrillator Electrodes Recall for Pediatric Energy Delivery Risk

    ZOLL Medical is recalling specific adult defibrillator electrodes that may cause R Series devices to deliver pediatric energy levels instead of adult levels.

    Product
    OneStep CPR Complete, Adult Multi Function Electrodes, Part Numbers: 8900 0214 01 (case of 8 single electrodes, UDI: 10847946016279) and 8900 0224 01 (single electrode, UDI: 00847946016272) Product Usage: Intended Use: Defibrillation, Cardioversion, Noninvasive Pacing, EGG…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0812-2018·2018-03-07

    ZOLL 731 Series Ventilators Recalled for Software Anomaly

    ZOLL Medical Corporation is recalling 46 units of 731 Series Ventilators due to a software anomaly that may allow users to inadvertently change device settings.

    Product
    731 Series Ventilators running software version 05.20.00 The devices in the ZOLL ventilator are indicated for use in the management of infant through adult patients weighing ;:: 5 kg with acute or chronic respiratory failure or during resuscitation by providing continuous…
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1311-2014·2014-04-09

    Zoll Medical Defibrillators Recalled for Continuous Device Reset Loop

    Zoll Medical is recalling 3,169 defibrillator/pacemaker/monitor units because they may latch in a continuous reset loop, rendering them unusable.

    Product
    Zoll Medical X Series, PropaqMD, PropaqM Defibrillator/Pacemaker/Monitor With System Software Version 02.10.02.00 or Higher, automated external defibrillator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2401-2012·2012-09-26

    Zoll X Series Defibrillators Recalled for Incorrect Software

    ZOLL Medical Corporation is recalling 11 Zoll X Series Defibrillator/Pacemaker/Monitor units because they were shipped with incorrect software.

    Product
    Zoll X Series Defibrillator/Pacemaker/Monitor Product Usage: The product is used by qualified medical personnel for the purpose of converting ventricular fibrillation to sinus rhythm or other cardiac rhythms capable of producing hemodynamically significant heart beats. In…
    Category
    Medical Device
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

ZOLL Medical

manufacturer of medical technology products

Official website

Source: Wikidata (Q118075142), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.