20 recalls in our database name Tyber Medical as the manufacturing or recalling firm.

What the numbers show

Total
20
Critical
0
Severe
0
Most recent
2026-01-28

Of the 20 recalls from Tyber Medical we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–20 of 20

  • ModerateFDA (Devices)·Z-1132-2026·2026-01-28

    Long distal radius plates recalled over an incorrect thread orientation

    Tyber Medical is recalling 64 units VOLT Wrist Treatment System distal radius plates because the supplier manufactured anatomical left plates with an incorrect thread orientation.

    Product
    Brand Name: VOLT" Wrist Treatment System Product Name: 2.4/2.7 2Column Dist Radius Plate 6Hd/14Shaft/Left/Std/186mm Model/Catalog Number: 02.426.691S Product Description: 2 Column Distal Radius Plate - 6 Head, 14 Shaft, Standard Left - 186mm Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1131-2026·2026-01-28

    Distal radius plates recalled over an incorrect thread orientation

    Tyber Medical is recalling 100 VOLT Wrist Treatment System distal radius plates because the supplier manufactured anatomical left plates with an incorrect thread orientation.

    Product
    Brand Name: VOLT" Wrist Treatment System Product Name: 2.4/2.7 2Column Dist Radius Plate 6Hd/10Shaft/Left/Std/139mm Model/Catalog Number: 02.426.681S Product Description: 2 Column Distal Radius Plate - 6 Head, 10 Shaft, Standard Left - 139mm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1211-2025·2025-03-05

    Tyber Medical recalls A.L.P.S. mvX Anatomic Lateral Fibula Plates due to screw malposition

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates (418 units, nationwide) because the locking screw may pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX -ANATOMIC LAT FIB PLATE 6H LT- Anatomic Lateral Fibula Plate, 6-hole, Left Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770708061
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1217-2025·2025-03-05

    Orthopedic Plate Locking Screw May Pass Through Hole During Surgery

    Tyber Medical is recalling A.L.P.S. mvX-P Anatomic Lateral Fibula Plates because the locking screw may pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX-P: ANATOMIC LAT FIB PLATE 12H LT- Anatomic Lateral Fibula Plate, 12-Hole, Left. Inended for Fixation of fractures of the distal tibia Model/Catalog Number: 770708121
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1220-2025·2025-03-05

    Medial tibia plate screw locking defect causes surgical delays

    Tyber Medical is recalling A.L.P.S. mvX Medial Tibia Plates because the locking screw may pass through the locking hole during surgery instead of securing properly, causing surgical delays. The recall affects 210 units distributed nationwide.

    Product
    A.L.P.S. mvX- MEDIAL TIBIA PLATE 6H RT-Medial Tibia Plate, 6-Hole, Right Model/Catalog Number: 770715062 Intended for Fixation of fractures of the distal tibia
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1214-2025·2025-03-05

    Orthopedic Surgical Plates Recalled Due to Intra-Operative Locking Screw Malfunction

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates nationwide due to reports that locking screws may pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 8H RT: Anatomic Lateral Fibula Plate, 8-hole, Right Indicated for use in Fixation of fractures of the distal tibia Model/Catalog Number: 77070802
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1212-2025·2025-03-05

    A.L.P.S. mvX Fibula Plate Recall: Locking Screw Malfunction During Surgery

    Tyber Medical is recalling 408 units of the A.L.P.S. mvX Anatomic Lateral Fibula Plate because the locking screw can pass through the locking hole during surgery, causing surgical delays. No injuries have been reported.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 6H RT: Anatomic Lateral Fibula Plate, 6-hole, Right Model/Catalog Number: 770708062
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1223-2025·2025-03-05

    FDA Recalls Medial Tibia Plates for Intra-operative Screw Failure

    Tyber Medical is recalling A.L.P.S. mvX Medial Tibia Plates due to reports that the locking screw can pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX-MEDIAL TIBIA PLATE 12H LT-Medial Tibia Plate, 12-Hole, Left Intended forFixation of fractures of the distal tibia Model/Catalog Number: 770715121
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1213-2025·2025-03-05

    Orthopedic plate recall: locking screw may pass through hole during surgery

    Tyber Medical is recalling 214 units of A.L.P.S. mvX orthopedic plates (nationwide) because the locking screw may pass through the locking hole during surgery. Surgical delays have been reported.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 8H LT: Anatomic Lateral Fibula Plate, 8-hole, Left Intended to bridge or otherwise stabilize bone fragments to facilitate healing. Model/Catalog Number: 770708081
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1226-2025·2025-03-05

    Medial Tibia Plate Recall Due to Locking Screw Malfunction During Surgery

    Tyber Medical recalls 109 units of the A.L.P.S. mvX Medial Tibia Plate nationwide due to reports of the locking screw passing through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- MEDIAL TIBIA PLATE 16H RT -Medial Tibia Plate, 16-Hole, Right Intended Fixation of fractures of the distal tibia Model/Catalog Number: 770715162
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1209-2025·2025-03-05

    Anatomic Lateral Fibula Plate recalled for locking screw malfunction

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates due to reports of locking screws passing through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX - ANATOMIC LAT FIB PLATE 4H LT: Anatomic Lateral Fibula Plate, 4-hole, Left Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770708041
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1215-2025·2025-03-05

    Anatomic Lateral Fibula Plate locking screw malfunction during surgery

    Tyber Medical is recalling 220 A.L.P.S. mvX Anatomic Lateral Fibula Plates due to complaints that the locking screw passes through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- Product Name: ANATOMIC LAT FIB PLATE 10H LT Anatomic Lateral Fibula Plate, 10-Hole, Left. Intended Fixation of fractures of the distal tibia Model/Catalog Number: 770708101
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1225-2025·2025-03-05

    Medical plate locking screw may fail during fracture surgery

    A locking screw in the A.L.P.S. mvX Medial Tibia Plate may pass through its locking hole during surgery. Surgical delays have been reported with this device.

    Product
    A.L.P.S. mvX- MEDIAL TIBIA PLATE 16H LT-Medial Tibia Plate, 16-Hole, Left Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770715161
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1221-2025·2025-03-05

    Medial Tibia Plate Recall: Locking Screw Defect During Surgery

    Tyber Medical is recalling A.L.P.S. mvX Medial Tibia Plates because the locking screw may not properly secure during surgery, causing surgical delays. No injuries have been reported.

    Product
    A.L.P.S. mvX- MEDIAL TIBIA PLATE 10H LT- Medial Tibia Plate, 10-Hole, Left. Intended Fixation of fractures of the distal tibia Model/Catalog Number: 770715101
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1219-2025·2025-03-05

    Orthopedic tibia plate locking screw failure causes surgical delays

    Tyber Medical recalls A.L.P.S. mvX Medial Tibia plates; the locking screw can pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX-MEDIAL TIBIA PLATE 6H LT-Medial Tibia Plate, 6-Hole, Left Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770715061
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1218-2025·2025-03-05

    Orthopedic Fixation Plates Recalled for Screw Locking Failure During Surgery

    Tyber Medical is recalling 115 A.L.P.S. mvX orthopedic plates because the locking screw can pass through the locking hole during surgery, causing surgical delays and inadequate fracture fixation.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 12H RT- Anatomic Lateral Fibula Plate, 12-Hole, Right. Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770708122 Product Description:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1224-2025·2025-03-05

    A.L.P.S. mvX Medial Tibia Plate Locking Screw Malfunction Recall

    Tyber Medical recalls 208 units of A.L.P.S. mvX Medial Tibia Plates due to locking screws that can pass through the locking hole during surgery, causing surgical delays. No patient injuries have been reported.

    Product
    A.L.P.S. mvX--MEDIAL TIBIA PLATE 12H RT-Medial Tibia Plate, 12-Hole, Right Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770715122
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1222-2025·2025-03-05

    Orthopedic Tibia Plate Locking Screw Malfunction Nationwide Recall

    Tyber Medical is recalling 209 A.L.P.S. mvX Medial Tibia plates nationwide due to reports that locking screws can pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX-MEDIAL TIBIA PLATE 10H RT-Medial Tibia Plate, 10-Hole, Right Intended Fixation of fractures of the distal tibia. Model/Catalog Number: 770715102
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1210-2025·2025-03-05

    Orthopedic fibula plate locking screw failure during surgery

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates due to locking screw passing through the locking hole intra-operatively, causing surgical delays. The recall affects 397 units distributed nationwide.

    Product
    A.L.P.S. mvX -ANATOMIC LAT FIB PLATE 4H RT: Anatomic Lateral Fibula Plate, 4-hole, Right Model/Catalog Number: 770708042
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1216-2025·2025-03-05

    Anatomic lateral fibula plate locking screw failure during surgery

    Tyber Medical A.L.P.S. mvX anatomic lateral fibula plates (219 units nationwide) have a defect where the locking screw can pass through its locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 10H RT- Anatomic Lateral Fibula Plate, 10-Hole, Right. Intended forFixation of fractures of the distal tibia Model/Catalog Number: 770708102 Product Description:
    Category
    Medical Device
    Distribution
    Distributed nationwide