10 recalls in our database name Trilliant Surgical Ltd. as the manufacturing or recalling firm.

What the numbers show

Total
10
Critical
0
Severe
0
Most recent
2018-07-11

Of the 10 recalls from Trilliant Surgical Ltd. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–10 of 10

  • ModerateFDA (Devices)·Z-0960-2017·2017-01-18

    Trilliant Tiger Screw Sterilization Tray Base Assembly Recall for Printing Error

    Trilliant Surgical Ltd. is recalling Tiger Screw Sterilization Tray Base Assemblies due to a printing error on k-wire description markings.

    Product
    Tiger Screw Sterilization Tray Base Assembly Model 210-00-001 Revision N, O The product is a component of a system indicated for the fixation of fractures, non-unions, arthrodeses, and osteotomies of bones appropriate for the size of the device.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0609-2017·2016-11-23

    Trilliant Surgical Recalls Cannulated Headless Screws Due to Labeling Errors

    Trilliant Surgical Ltd. is recalling 11 units of Model 208-70-110 cannulated headless screws because they bear incorrect part and lot numbers on the labels.

    Product
    Model 208-70-110, Long Thread Tiger Large Cannulated Headless Screw, 7 x 110 mm labeled as "7.0 x 110mm LTTHCS REF 208-70-110 QTY 30 LOT TSL003721 2016-03-29 Trilliant Surgical, LTD"
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-2738-2015·2015-09-16

    Trilliant Gridlock Screw Driver Bits Recalled for Out-of-Specification Dimensions

    Trilliant Surgical Ltd. is recalling 108 units of Gridlock Screw Driver Bits because they are out of specification, which may cause screw heads to strip during surgery.

    Product
    2.4, 3.0, and 4.0 mm Gridlock Screw Driver Bit, Model Number 310-30-003, Lot Number TSL002605, NON-STERILE. For use with the Gridlock Plating System for trauma and reconstructive procedures of small bones.
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-2490-2015·2015-09-09

    Trilliant Surgical Recalls Out-of-Specification Fibula Plates

    Trilliant Surgical Ltd. is recalling 28 units of VL Gridlock Fibula Plates because insufficient thread depth may limit locking screw functionality.

    Product
    7 Hole VL Gridlock Fibula Plate, Part # 300-60-001 NON-STERILE SINGLE USE ONLY; 9 Hole VL Gridlock Fibula Plate, Part # 300-60-002 NON-STERILE SINGLE USE ONLY; 11 Hole VL Gridlock Fibula Plate, Part # 300-60-003 NON-STERILE SINGLE USE ONLY. For use in trauma and reconstructive pr
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-2456-2015·2015-09-02

    Trilliant Surgical Reamer Heads Recalled for Guide Pin Fit Issues

    Trilliant Surgical Ltd. is recalling 638 Concave and Convex Reamer Heads because the cannulation may be too small to allow the Guide Pin to pass through freely.

    Product
    Concave Reamer Head, 16 mm; Concave Reamer Head, 18 mm; Concave Reamer Head, 20 mm; Concave Reamer Head 22 mm; Convex Reamer Head, 16 mm; Convex Reamer Head, 18 mm; Convex Reamer Head 20 mm; Convex Reamer Head 22 mm, used with Gridlock Plating system, for use in trauma and recons
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2464-2015·2015-09-02

    Trilliant Surgical Recalls Tiger Cannulated Screw System Tray Lids

    Trilliant Surgical Ltd. is recalling 71 units of Tiger Cannulated Tray Lids because they are occasionally difficult to remove from sterilization trays.

    Product
    Tiger Cannulated Tray Lid Part # 210-00-001-1 NON-STERILE; Combined Tiger/Headless Screw Part # 210-99-101 NON-STERILE; These are components of the Tiger Cannulated Screw System and the Tiger Headless Cannulated Screw System The Tiger Cannulated Screw Fixation System and the Tig
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2452-2015·2015-09-02

    Trilliant Surgical Recalls 3.0/4.0 Cannulated Drill Bits Due to Sizing Issue

    Trilliant Surgical Ltd. is recalling 121 units of 3.0/4.0 Cannulated Drill Bits because the inner diameter is too small for the guide wire to pass through.

    Product
    3.0/4.0 Cannulated Drill Bit; a component of the Tiger Cannulated Screw System The Tiger Cannulated Screw Fixation System implants are intended for fixation of fractures, non-unions, arthrodesis and osteotomies of the small bones in the hand and foot. The implants and guide wire
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2421-2015·2015-08-26

    Trilliant Surgical Recalls Non-Sterile Cannulated Screw Countersinks

    Trilliant Surgical Ltd. is recalling 102 units of non-sterile cannulated screw countersinks because their cutting efficiency was out of specification.

    Product
    2.0/2.4 Cannulated Screw Countersink Part # 210-24-002 NON-STERILE and 3.0/4.0 Cannulated Screw Countersink Part # 210-40-002 NON-STERILE Product Usage: The Tiger Cannulated Screw Fixation System implants are intended for fixation of fractures, non-unions, arthrodesis, and
    Category
    Medical Device
    Distribution
    Distributed nationwide