12 recalls in our database name Thoratec LLC as the manufacturing or recalling firm.

What the numbers show

Total
12
Critical
1
Severe
2
Most recent
2026-06-24

Of the 12 recalls from Thoratec LLC we have scored against our rubric, 1 (8%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2 (17%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–12 of 12

  • HighFDA (Devices)·Z-2518-2026·2026-06-24

    HeartMate 3 assist system kits recalled over backup battery failures

    HeartMate 3 Left Ventricular Assist System kits, model 106524US, are being recalled due to 11 volt backup battery failures. Four units are affected.

    Product
    Brand Name: HeartMate Product Name: HeartMate 3 Left Ventricular System (LVAS) Kits Model/Catalog Number: 106524US Software Version: N/A Product Description: The HeartMate 3" Left Ventricular Assist System (LVAS) is a set of equipment and materials that together comprise a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2519-2026·2026-06-24

    HeartMate 3 system controllers recalled over backup battery failures

    HeartMate 3 System Controllers, model 106531US, are being recalled due to 11 volt backup battery failures. 694 units are affected.

    Product
    Brand Name: HeartMate Product Name: HeartMate 3" System Controller Model/Catalog Number: 106531US Software Version: N/A Product Description: The HeartMate 3" System Controller acts as the central power and communication hub for the HeartMate 3 LVAS. It passes power from the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2520-2026·2026-06-24

    HeartMate 11 volt lithium ion backup batteries may fail

    HeartMate 11 Volt Lithium Ion Standalone Backup Batteries, model 106128, are being recalled due to 11 volt backup battery failures. Twelve units are affected.

    Product
    Brand Name: HeartMate Product Name: HM 11V Li-ion Backup Battery, ABT Model/Catalog Number: 106128 Software Version: N/A Product Description: The HeartMate 11 Volt Lithium Ion Standalone Backup Battery is a component of the HeartMate 3" System Controller and provides power…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1099-2026·2026-01-21

    Circulatory support blood pumps recalled over locking into the motor

    Thoratec is recalling 8,399 CentriMag blood pump products after reports that the pump may not fit or lock securely into the motor using the screw-in locking feature.

    Product
    CentriMag Blood Pump, REF: 102953, 201-20003, 201-90010, 201-90016; CentriMag RVAD HDE KIT, REF: 104318; CentriMag Pre-connected Pack, REF: CMAEK00; CentriMag VAD KIT, REF: 201-51006, 201-51007, 201-90001 201-90001T; Blood Pump with CentriMag Acute Circulatory Support System…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0506-2026·2025-11-26

    Heart pump controllers recalled over corrosion at the backup battery connector

    Thoratec is recalling 35,376 HeartMate 3 Controllers because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate 3 Controller (Standalone) Model/Catalog Number: 106531US, HeartMate 3 Controller, US; 106531INT, HeartMate 3 Controller, OUS; 106531LF2, HeartMate 3 Low Flow 2.0 Controller Software Version: N/A Product Description: The HeartMate…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0505-2026·2025-11-26

    Heart pump kits recalled over corrosion at the backup battery connector

    Thoratec is recalling 29,059 HeartMate 3 Left Ventricular System kits because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate 3 Left Ventricular System (LVAS) Kits Model/Catalog Number: 106524US, HeartMate 3 LVAS KIT, US; 106524INT, HeartMate 3 LVAD KIT, OUS; 106524 Software Version: N/A Product Description: The HeartMate 3" Left Ventricular Assist…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0507-2026·2025-11-26

    Heart pump implant kits recalled over corrosion at the battery connector

    Thoratec is recalling 248 HeartMate II LVAS Implant Kits because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate II¿ LVAS Implant Kit Model/Catalog Number: 106015, HeartMate II¿ LVAS Kit, with Pocket Controller, Sealed, US; 106016, HeartMate II¿ LVAS Kit, with Pocket Controller, Sealed, EU Software Version: N/A Product Description: The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0508-2026·2025-11-26

    HeartMate II controllers recalled over corrosion at the battery connector

    Thoratec is recalling 2,424 HeartMate II Pocket Controllers because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate II¿ Controller (standalone) Model/Catalog Number: 106017, HeartMate II¿ Pocket Controller, US; 106762, HeartMate II¿ Pocket Controller, US; 107801, HeartMate II¿ Pocket Controller Software Version: N/A Product Description: The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2290-2025·2025-08-20

    HeartMate mobile power unit cords recalled over locking feature that may disconnect

    Abbott is recalling 53 HeartMate Mobile Power Unit AC power cords, model 107760, because a misaligned V-Lock may not engage and can allow an unintended disconnect. The FDA classified this as Class I.

    Product
    Brand Name: HeartMate Product Name: Mobile Power Unit, AC Power Cord Model/Catalog Number: 107760 Software Version: N/A Product Description: The HeartMate 3" Left Ventricular Assist System (LVAS) is a set of equipment and materials that together comprise a medical device…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2291-2025·2025-08-20

    HeartMate mobile power unit cords may disconnect from a misaligned lock

    HeartMate Mobile Power Units are being recalled because misaligned V-Lock features on the power cords prevent the locking mechanism engaging properly and may cause unintended disconnect. 604 units affected.

    Product
    Brand Name: HeartMate Product Name: Mobile Power Unit Model/Catalog Number: 107754 Software Version: N/A Product Description: The HeartMate 3" Left Ventricular Assist System (LVAS) is a set of equipment and materials that together comprise a medical device designed to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1570-2025·2025-04-23

    HeartMate Mobile Power Unit electrical malfunction may cause loss of power

    Thoratec LLC is recalling HeartMate Mobile Power Units due to an electrical component defect that may prevent the unit from turning on, cause unprompted shut down, or trigger false alarms. If power is lost and not switched to rechargeable batteries within 15 minutes, the connected pump may lose power.

    Product
    HeartMate Mobile Power Unit: REF: 107754, NA; 107758, EU; 107758AU, AU; 107758UK, UK; L107758, EU Rental. Used with HeartMate 3 and II Left Ventricular Assist System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2583-2024·2024-08-21

    HeartMate 3 System Controller membrane may lift, risking fluid damage and device failure

    Thoratec LLC is recalling 694 HeartMate 3 System Controllers because the UI membrane may lift along the housing, allowing fluid entry that could damage internal circuits and cause loss of power or pump failure.

    Product
    HeartMate 3 System Controllers provided within the following HeartMate 3 Left Ventricular Assist System (LVAS) Implant Kits or distributed separately: HeartMate 3 LVAS Implant Kit, US, Model: 106524US; HeartMate 3 LVAS Implant Kit, OUS, Model: 106524INT; HeartMate 3 System…
    Category
    Medical Device
    Distribution
    42 states

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Thoratec

American medical device manufacturer

Country
United States
Founded
1976

Official website