The Recall Desk

Manufacturer

Thoratec Corporation

7 recalls in our database name Thoratec Corporation as the manufacturing or recalling firm.

What the numbers show

Total
7
Critical
4
Severe
3
Most recent
2017-05-31

Of the 7 recalls from Thoratec Corporation we have scored against our rubric, 4 (57%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 3 (43%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–7 of 7

  • SevereFDA (Devices)·Z-2052-2017·2017-05-31

    St. Jude Medical HeartMate II LVAS Pocket Controller Software and Hardware Update

    St. Jude Medical is providing software and hardware updates to HeartMate II LVAS Pocket Controllers to facilitate the exchange to a backup controller.

    Product
    HeartMate¿ II LVAS with Pocket Controller; 106015 - HMII LVAD SEALED KIT-PCTRL, NA UDI: 00813024011224 Intended to provide hemodynamic support in patients with end-stage, refractory left ventricular heart failure; intended for use inside or outside the hospital.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2051-2017·2017-05-31

    St. Jude Medical HeartMate II LVAS Software and Hardware Update Recall

    St. Jude Medical is updating software and hardware for HeartMate II LVAS devices to facilitate the exchange to a backup controller.

    Product
    HeartMate¿ II LVAS with Pocket Controller; 107801 - HMII PUMP & POCKET CTRL ONLY UDI:00813024011286 Intended to provide hemodynamic support in patients with end-stage, refractory left ventricular heart failure; intended for use inside or outside the hospital.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2053-2017·2017-05-31

    St. Jude Medical HeartMate II LVAS Pocket Controller Software and Hardware Update

    St. Jude Medical is providing software and hardware updates to HeartMate II LVAS Pocket Controllers to facilitate the exchange to a backup controller.

    Product
    HeartMate¿ II LVAS with Pocket Controller; 106762 - HMII POCKET CONTROLLER, NA; UDI: 00813024011286 Intended to provide hemodynamic support in patients with end-stage, refractory left ventricular heart failure; intended for use inside or outside the hospital.
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-1227-2014·2014-04-02

    Thoratec HeartMate II Implant Kit Recalled Due to Controller Switching Injuries

    Thoratec is recalling HeartMate II Implant Kits because serious injuries and deaths occurred when patients switched from primary to backup System controllers.

    Product
    HeartMate II Implant Kit with Pocket Controller; with sealed grafts (NAm) with sealed grafts (EU) Product Usage: HeartMate II is a mechanical device that circulates blood throughout the body when the heart is too weak to pump blood adequately on its own.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1230-2014·2014-04-02

    Thoratec HeartMate II Pocket Controllers Recalled Due to Reported Deaths

    Thoratec is recalling HeartMate II Pocket Controllers because serious injuries and deaths were reported when patients switched from primary to backup controllers.

    Product
    Heart Mate II Pocket Controllers removed from packaging Product Usage: HeartMate II is a mechanical device that circulates blood throughout the body when the heart is too weak to pump blood adequately on its own.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1228-2014·2014-04-02

    Thoratec HeartMate II System Controller Recalled Due to Injury and Death Reports

    Thoratec is recalling HeartMate II System Controllers because serious injuries and deaths occurred when patients switched from primary to backup controllers.

    Product
    HeartMate II System Controller Product Usage: HeartMate II is a mechanical device that circulates blood throughout the body when the heart is too weak to pump blood adequately on its own. It is sometimes called a a heart pump or VAD. HeartMate II is a small implantable LVAD.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-229-2014·2014-04-02

    Thoratec HeartMate II LVAD Pump Recall Due to Controller Switching Injuries

    Thoratec is recalling 36 HeartMate II LVAD Pump and Pocket Controller Kits because switching from the primary to the backup controller caused serious injuries and deaths.

    Product
    HeartMate II LVAD Pump and Pock Controller Kit; Product Usage: HeartMate II is a mechanical device that circulates blood throughout the body when the heart is too weak to pump blood adequately on its own.
    Category
    Medical Device
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Thoratec

American medical device manufacturer

Country
United States
Founded
1976

Official website