The Recall Desk

Manufacturer

Think Surgical, Inc.

3 recalls in our database name Think Surgical, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
3
Critical
0
Severe
1
Most recent
2026-07-15

Of the 3 recalls from Think Surgical, Inc. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1 (33%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–3 of 3

  • SevereFDA (Devices)·Z-2716-2026·2026-07-15

    TMINI Tracking Array knob loosening causing potential array misalignment

    Think Surgical is recalling TMINI Femur and Tibia Tracking Arrays used in knee replacement surgery because the knob on the tracking array may loosen, causing potential misalignment of the array.

    Product
    TMINI Femur Tracking Array REF 109003 UDI-DI code: M9461090030 TMINI Tibia Tracking Array REF 109004 UDI-DI code: M9461090040 TMINI Miniature Robotic System is indicated as a stereotaxic instrumentation system for total knee replacement (TKA) surgery. It is to assist the
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1318-2024·2024-03-27

    TMINI Knee Instrument Array Guide May Bind During Surgical Drilling

    A precision component in Think Surgical's TMINI robotic knee system may bind due to insufficient clearance. The binding could occur during surgical drilling.

    Product
    Assembly, Array Guide TMINI, REF: 109101, part of the TMINI Knee Instrument Set, used with the TMINI Miniature Robotic System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2605-2018·2018-08-15

    Think Surgical Cutter Recall Due to Potential Head Detachment

    Think Surgical is recalling 951 flat cutters used in total knee arthroplasty because the cutter head may detach from the shaft.

    Product
    Think Surgical Cutter, Flat, ¿6.2mm x 144mm. For use only with the TCAT Computer-Assisted Tool. Part Number 106428 The cutter is used to prepare the bone for the (TKA) Total Knee Arthroplasty.
    Category
    Medical Device
    Distribution
    4 states

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Think Surgical (United States)

company in Fremont, United States

Country
United States
Founded
2007

Official website

Source: Wikidata (Q106411822), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.