The Recall Desk

Manufacturer

TECHNO-PATH MANUFACTURING LTD.

5 recalls in our database name TECHNO-PATH MANUFACTURING LTD. as the manufacturing or recalling firm.

What the numbers show

Total
5
Critical
0
Severe
0
Most recent
2025-11-19

Of the 5 recalls from TECHNO-PATH MANUFACTURING LTD. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–5 of 5

  • HighFDA (Devices)·Z-0502-2026·2025-11-19

    Second control serum lot recalled over negative HBsAg analyte recovery

    Techno-Path is recalling 51 units of Multichem ID-B positive control serum from a second lot because of potential negative recovery of the HBsAg analyte on the Alinity i platform.

    Product
    Multichem ID-B. Model Number: SR103B. Intended for use as an unassayed positive qualitative quality control serum to monitor the precision of laboratory testing procedures for the determination of anti-HIV-1 IgG, anti-HBc IgG, anti-HTLV-I IgG, anti-HCV IgG, HBs antigen and…
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-0501-2026·2025-11-19

    Positive control serum recalled over negative recovery of the HBsAg analyte

    Techno-Path is recalling 76 units of Multichem ID-B positive control serum because of potential negative recovery of the HBsAg analyte on the Alinity i platform.

    Product
    Multichem ID-B. Model/Catalog Number: SR103B Intended for use as an unassayed positive qualitative quality control serum to monitor the precision of laboratory testing procedures for the determination of anti-HIV-1 IgG, anti-HBc IgG, anti-HTLV-I IgG, anti-HCV IgG, HBs antigen…
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-0104-2024·2023-10-18

    Multichem control vials break during shipping or thawing due to glass defect

    TECHNO-PATH MANUFACTURING LTD. is recalling Multichem S Plus and related control vials due to a defect in the glass vial commodity. The vials may break during delivery, thawing, or opening, potentially exposing users to biohazardous material and delaying patient results.

    Product
    Multichem S Plus, Part Codes: a) 08P88-10, b) 08P88-11, c) 08P88-12
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0106-2024·2023-10-18

    Glass Vials in Laboratory Control Products Recalled for Breakage Risk

    Multichem P and related laboratory control products are recalled due to defective glass vials that may break during delivery or use, potentially exposing users to biohazardous material.

    Product
    Multichem P, Part Code 08P90-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0105-2024·2023-10-18

    Multichem IA Plus and Controls Recalled Due to Broken Glass Vials

    TECHNO-PATH MANUFACTURING LTD. is recalling Multichem IA Plus and related controls due to broken glass vials that may expose laboratory personnel to biohazardous material. Affected lots should be discontinued immediately.

    Product
    Multichem IA Plus, Part Codes: a) 08P86-10, b) 08P86-19
    Category
    Medical Device
    Distribution
    Distributed nationwide