The Recall Desk

Manufacturer

Smiths Medical ASD, Inc.

293 recalls in our database name Smiths Medical ASD, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
293
Critical
9
Severe
71
Most recent
2025-05-14

Of the 293 recalls from Smiths Medical ASD, Inc. we have scored against our rubric, 9 (3%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 71 (24%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

101–125 of 293

  • SevereFDA (Devices)·Z-2421-2024·2024-08-14

    Smiths Medical CADD-Solis VIP Ambulatory Infusion Pumps Recalled Worldwide

    Smiths Medical is recalling CADD-Solis VIP ambulatory infusion pumps (models 21-2120, 21-2125, 21-2127) worldwide. The FDA has classified this as a Class I recall.

    Product
    CADD-Solis VIP ambulatory Infusion Pumps, Model 2120 (21-2120, 21-2125, and 21-2127) Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site, epidural space or subarachnoid space. Therapies t
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1543-2024·2024-04-24

    Smiths Medical Medfusion Pump Guide Barrel Clamp Molding Defect Recall

    Smiths Medical is recalling Medfusion Guide Barrel Clamps due to a molding defect that could cause spring slippage, preventing the pump from recognizing or correctly identifying loaded syringes.

    Product
    Smiths Medical Medfusion Guide Barrel Clamp, Item number G6000716
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1542-2024·2024-04-24

    Smiths Medical syringe pumps recalled for molding defect in barrel clamp guide

    Smiths Medical is recalling certain Model 3010 syringe pumps due to a molding defect in the barrel clamp guide that may prevent proper syringe recognition. Affected units were manufactured or serviced between July 2016 and April 2021.

    Product
    Smiths Medical Model 3010 Syringe pumps: a. Protege Model 3010, b. Medfusion Model 3010A, c. Protege UK Model 3010E
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1540-2024·2024-04-24

    Smiths Medical Medfusion Syringe Pumps May Fail to Recognize Syringes

    Smiths Medical is recalling certain Medfusion Models 4000, 3500, and 3010 syringe pumps due to a barrel clamp guide defect. The defect may prevent the pump from recognizing or correctly identifying a syringe, potentially affecting medication delivery.

    Product
    Smiths Medical Medfusion Model 3500 Syringe pumps, Item Numbers: a) 3500 b) 3500-0600-00 c) 3500-0600-01 d) 3500-0600-249 e) 3500-0600-50 f) 3500-0600-51 g) 3500-0600-82 h) 3500-306 i) 3500-402 j) 3500-414 k) 3500-415 l) 3500-500 m) 3500E n) 3500VX-306 o) 3500VX-
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1541-2024·2024-04-24

    Smiths Medical Medfusion syringe pumps may fail to recognize syringes

    Smiths Medical syringe pumps with defective barrel clamp guides may fail to recognize or correctly identify loaded syringes, potentially affecting medication delivery accuracy.

    Product
    Smiths Medical Medfusion Model 4000 Syringe pump, Item Numbers: a) 4000-0101-249, b) 4000-0101-50, c) 4000-0101-51, d) 4000-0105-249, e) 4000-0105-50, f) 4000-0105-51, g) 4000-0105-78, h) 4000-0106-00, i) 4000-0106-01, j) 4000-0106-231,
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1275-2024·2024-03-27

    Smiths Medical Pneupac Plus 300 Ventilator Cycling Malfunction

    Smiths Medical Pneupac Plus 300 ventilators may intermittently deliver continuous airflow instead of cycling breaths as designed. This malfunction affects 2,902 units distributed worldwide.

    Product
    smiths medical Pneupac paraPAC plus 300 ventilator kit without PEEP and CPAP, REF P300NUS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1274-2024·2024-03-27

    Smiths Medical Pneupac paraPAC plus 310 ventilators recalled for malfunction

    Smiths Medical is recalling paraPAC plus 310 ventilators that may malfunction by delivering continuous gas flow instead of cycling breaths. The defect affects 10,140 units distributed worldwide and prevents proper ventilation.

    Product
    smiths medical Pneupac paraPAC plus 310 ventilator kit with PEEP and CPAP, REF P310NUS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0863-2024·2024-02-07

    Smiths Medical Medfusion Model 3500 Syringe Pump Software Defects

    Smiths Medical recalls Medfusion Model 3500 syringe pumps (software versions before v6.0.0) due to multiple programming defects that could affect medication delivery rates, timing, and accuracy.

    Product
    smiths medical Medfusion Model 3500 Syringe pump
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0864-2024·2024-02-07

    Smiths Medical Medfusion 4000 Syringe Pump Software Defects Recall

    The FDA is recalling Smiths Medical Medfusion Model 4000 syringe pumps due to software defects affecting medication delivery, alarms, and display accuracy. Users should install the latest software version to correct these issues.

    Product
    smiths medical Medfusion Model 4000 syringe pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0740-2024·2024-01-24

    Medical Device Stopcock Recalled Due to O-Ring Seal Defect

    Smiths Medical Asd Inc is recalling approximately 31,685 Stopcock Left Rotator devices due to oversized O-rings that may compromise seal integrity. The defect may cause medication leaks, potentially resulting in under-infusion during treatment.

    Product
    1050 STOPCOCK LEFT ROTATOR OFF HANDLE, List Number MX1431MRL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0739-2024·2024-01-24

    Medex LOGICAL CATH LAB KIT Recalled for Oversized O-Ring Defect

    Smiths Medical is recalling the Medex LOGICAL CATH LAB KIT due to a manufacturing defect where the O-ring inner diameter may be oversized, affecting seal integrity and potentially leading to medication under-infusion.

    Product
    Medex LOGICAL CATH LAB KIT, List Number M20754
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0745-2024·2024-01-24

    Braided Injection Line Recalled for Potential Medication Leaks

    Smiths Medical is recalling approximately 31,685 units of a braided injection line due to manufacturing defects in the O-ring seal. The defect may cause medication leaks that reduce drug delivery.

    Product
    20IN (50.8CM) BRAIDED INJ LINE, ROTATING ADAPT, List Number MX682BR
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0742-2024·2024-01-24

    Medex 700PSI Stopcock with Rotator Recalled Due to Seal Defect

    Smiths Medical is recalling Medex 700PSI stopcocks with rotators due to a manufacturing defect affecting the O-ring seal. The defect may cause medication leakage and under-infusion during patient treatment.

    Product
    Medex 700PSI STOPCOCK W/ROTATOR, List Number MX4331R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0741-2024·2024-01-24

    FDA Recalls Medical Pressure Tubing With Defective O-Ring Seals

    Smiths Medical is recalling 31,685 units of pressure tubing with defective O-rings that may not seal properly during medication infusion, potentially causing medication leaks and underdosing. The defect affects specific lot numbers with worldwide distribution.

    Product
    6IN PRESSURE TUBING, List Number MX20617
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0743-2024·2024-01-24

    High Pressure Rotator Infusion Device Recalled Due to Seal Defect

    Smiths Medical is recalling 31,685 HIGH PRESSURE ROTATOR infusion devices with a manufacturing defect that may cause an inadequate seal. The defect could lead to medication leaks and under-infusion.

    Product
    HIGH PRESSURE ROTATOR WITH MALE LUER LOCK, List Number MX496HP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0746-2024·2024-01-24

    Medex Injection Line Rotating Adapter Recalled Due to O-Ring Defect

    Smiths Medical is recalling Medex injection line rotating adapters due to a manufacturing defect where the O-ring inner diameter may be oversized, potentially causing medication leaks during infusion.

    Product
    Medex 20IN (50.8CM) INJ LINE ROTATING ADAPT, List Number MX682R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0744-2024·2024-01-24

    High Pressure Rotator with O-Ring Seal Defect Recalled Worldwide

    Smiths Medical is recalling High Pressure Rotators due to a manufacturing defect affecting O-ring seals. An oversized inner diameter may cause inadequate seal integrity, risking medication under-infusion.

    Product
    HIGH PRESSURE ROTATOR WITH FEMALE LUER LOCK, List Number MX497HP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0747-2024·2024-01-24

    Smiths Medical Injection Line Rotating Adapters Recalled for Seal Defect

    Smiths Medical is recalling specific injection line rotating adapters due to a manufacturing defect causing oversized O-rings that may lead to inadequate seal integrity and medication under-infusion.

    Product
    48IN (121.9CM) INJ LINE ROTATING ADAPT (900psi), List Number MX694R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0205-2024·2023-11-08

    Pediatric Tracheostomy Tube Recalled Due to Incorrect Box Expiration Date Label

    Smiths Medical recalls a pediatric tracheostomy tube because the outer box shows an incorrect expiration date (3/17/2021) while the actual product has the correct date (3/17/2026). The discrepancy could cause confusion about product validity.

    Product
    Smiths Medical Portex Bivona Pediatric Tracheostomy Tube, Cuffless, Model 60P045, Sterile.
    Category
    Medical Device
    Distribution
    18 states
  • HighFDA (Devices)·Z-0141-2024·2023-11-01

    Smiths Medical Blood Sampling Kits Missing Critical Filter Component

    Smiths Medical is recalling 31,900 Portex Pro-Vent Arterial Blood Sampling Kits due to missing filter components. Kits without the filter can produce inaccurate test results or expose users to infectious blood.

    Product
    Portex Pro-Vent Arterial Blood Sampling Kit with Dry Lithium Heparin for Gases and Electrolytes, REF 4599P-1
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0077-2024·2023-10-18

    Medfusion Syringe Pump Sensor Calibration Drift May Cause False Alarms

    Smiths Medical is recalling Medfusion Model 3500VX-500 Syringe Pumps due to force sensor calibration drift that can cause false alarms, system failures, or delayed occlusion detection.

    Product
    Medfusion Syringe Pump, Model 3500VX-500, v3, v4, v5, and v6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0076-2024·2023-10-18

    Medfusion Syringe Pumps Recalled for Force Sensor Calibration Drift

    The Medfusion Syringe Pump Model 3500-500 may experience force sensor calibration drift, causing false alarms or delayed occlusion detection. Approximately 20,815 units are being recalled worldwide, with increased risk in devices manufactured before April 2022.

    Product
    Medfusion Syringe Pump, Model 3500-500, v3, v4, v5, and v6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0078-2024·2023-10-18

    Syringe Pump Force Sensor Drift May Cause Detection Delays or False Alarms

    Smiths Medical Medfusion syringe pumps may have force sensors that drift out of calibration, causing delays in detecting line occlusions or triggering false alarms. Devices produced before April 2022 are at higher risk.

    Product
    Medfusion Syringe Pump, Model 3500-0600-XX: a) 0600-00; b) 0600-01; c) 0600-50; d) 0600-51; e) 0600-82; f) 0600-249; software versions: v3, v4, v5, and v6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0081-2024·2023-10-18

    Infusion pump component force sensor may malfunction or trigger false alarms

    Smiths Medical is recalling 118 units of Medfusion infusion pump plunger case components due to potential force sensor calibration drift. The sensor may malfunction, leading to delayed occlusion detection, false alarms, or system failure.

    Product
    Medfusion ASSEMBLY PLUNGER CASE LEFT 1/EA, Component Number G6001587, used on infusion pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0080-2024·2023-10-18

    Medfusion Infusion Pump Plunger Sensor Calibration Drift Recall

    Smiths Medical is recalling Medfusion infusion pump components due to a force sensor calibration issue that may cause delayed occlusion detection, false alarms, or system failures. No injuries have been reported.

    Product
    Medfusion PLUNGER FLOAT PLATE, Component Number G6000069, used on infusion pump
    Category
    Medical Device
    Distribution
    Distributed nationwide