The Recall Desk

Manufacturer

Siemens Healthcare Diagnostics, Inc.

668 recalls in our database name Siemens Healthcare Diagnostics, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
668
Critical
5
Severe
19
Most recent
2026-10-07

Of the 668 recalls from Siemens Healthcare Diagnostics, Inc. we have scored against our rubric, 5 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 19 (3%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

26–50 of 668

  • ModerateFDA (Devices)·Z-1821-2025·2025-06-04

    Atellica IM Homocysteine Calibrator recalled for assay instability

    Siemens Healthcare Diagnostics is recalling certain lots of Atellica IM Homocysteine Calibrator because calibrator instability causes increased positive bias and does not meet the assay reference interval requirements.

    Product
    Atellica IM Homocysteine Calibrator (2 Pack). Siemens Material Number: 10995498
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1684-2025·2025-05-07

    epoc BGEM BUN Test Cards for Blood Analysis System Recalled

    Siemens Healthcare Diagnostics is recalling epoc BGEM BUN Test Cards (25 pk) due to discrepant high pH results when samples are introduced with higher injection volumes on affected sensor configurations.

    Product
    epoc BGEM BUN Test Card (25 pk) for the epoc Blood Analysis System; Siemens Material Number (SMN): 10736515; epoc Software Version & Sensor Configuration: epoc Host SW v3.41.2, epoc NXS SW v4.14.9 & 4.14.11, Sensor Configuration 45.n.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1673-2025·2025-05-07

    Stratus CS Acute Care cTNI TestPak cardiac troponin test recall

    Siemens Healthcare Diagnostics is recalling Stratus CS Acute Care cTNI TestPak, a cardiac troponin I test, due to an increased occurrence of false positive results during the product's shelf life.

    Product
    Stratus CS Acute Care cTNI TestPak.IVD test for cardiac troponin I in heparinized plasma.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1685-2025·2025-05-07

    epoc BGEM Crea Test Card for Blood Analysis System recalled

    Siemens Healthcare Diagnostics is recalling epoc BGEM Crea Test Card (25 pk) units due to discrepant high pH results in samples with higher injection volumes. The recall affects 5,207 units distributed nationwide and internationally.

    Product
    epoc BGEM Crea Test Card (25 pk) for the epoc Blood Analysis System; Siemens Material Number (SMN): 10736382; epoc Software Version & Sensor Configuration: epoc Host SW v3.41.2, epoc NXS SW v4.14.9 & 4.14.11, Sensor Configuration 45.n.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1551-2025·2025-04-16

    Siemens Atellica CH Revised C Reactive Protein Assay Software Flagging Issue

    Siemens Healthcare Diagnostics is recalling the Atellica CH Revised C Reactive Protein assay due to incorrect software flagging that may produce erroneous results.

    Product
    Atellica CH Revised C Reactive Protein (RCRP); Siemens Material Number (SMN): 11537223.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0735-2025·2025-01-01

    Blood analyzer system recalled for patient name assignment software error

    Siemens recalled its epoc NXS Host blood analyzer due to a software malfunction that can assign incorrect patient names to test results, potentially leading to misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413497 (EU); Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0740-2025·2025-01-01

    Siemens Blood Analysis Device Recalled Over Patient Name Mix-up Software Defect

    Siemens is recalling the epoc NXS blood analysis system due to a software flaw that can assign incorrect patient names to test results, risking misdiagnosis or mistreatment if the operator doesn't verify the patient name.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413583(CN, KR) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0739-2025·2025-01-01

    Blood Analysis System Software Error Can Assign Wrong Patient Name

    Siemens epoc NXS Host blood analysis devices have a software malfunction that may assign the wrong patient name to blood test results, potentially leading to misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413518 (ROW) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0737-2025·2025-01-01

    Blood Analysis System Software Malfunction May Assign Incorrect Patient Names

    Siemens epoc NXS Host blood analysis systems contain a software malfunction that may assign incorrect patient names to blood measurements. This could result in clinicians making treatment decisions based on the wrong patient's test results.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413506 (CA); Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0738-2025·2025-01-01

    Siemens Blood Analysis System Software Malfunction May Cause Patient Identification Error

    Siemens epoc NXS Host blood analysis systems are recalled due to a software malfunction that can assign incorrect patient names to blood tests, potentially leading to misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413517(MX) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0767-2025·2025-01-01

    Siemens magnesium reagent cartridges recalled for false measurement results

    Siemens is recalling two lots of Magnesium Flex reagent cartridges due to potential falsely low magnesium measurements. The intermittent error may not be detected by standard quality control procedures.

    Product
    Magnesium Flex reagent cartridge, 360 tests, Catalog Number: K3057; Siemens Material Number (SMN): 10445158;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0741-2025·2025-01-01

    Siemens epoc blood analyzer software assigns incorrect patient names

    Siemens epoc NXS blood analysis system has a software defect that can incorrectly assign patient names to blood test results, potentially causing misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413879(IN) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0736-2025·2025-01-01

    Siemens epoc Blood Analysis System Recalled for Patient Identification Software Error

    Siemens is recalling epoc NXS Host blood analysis systems due to a software malfunction that can assign incorrect patient names to test results, potentially leading to misdiagnosis and mistreatment if not verified by the user.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413498(JP) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0734-2025·2025-01-01

    Blood Analysis System Recalled Due to Patient Name Assignment Software Error

    Siemens is recalling the epoc NXS Host blood analysis system due to a software defect that can incorrectly assign patient names to test results, potentially causing misdiagnosis and mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413475 (US); Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0597-2025·2024-12-11

    Siemens Atellica CI Analyzer may produce falsely elevated electrolyte test results

    Siemens' Atellica CI Analyzer may display incorrect diluent volume levels, causing falsely elevated sodium, potassium, and chloride test results in 559 units distributed worldwide.

    Product
    Atellica CI Analyzer. Catalog Numbers: 10947347.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0599-2025·2024-12-11

    Atellica CH β2-Microglobulin Reagent Produces Falsely Depressed Results

    Siemens Atellica CH β2-Microglobulin reagent may produce falsely depressed test results for samples between 18-30 mg/L, potentially leading to missed or delayed kidney disease diagnoses. No illnesses have been reported.

    Product
    Atellica¿ CH ¿2-Microglobulin (B2M) - In vitro diagnostic use in the quantitative determination of ¿2-microglobulin in human serum and plasma. Siemens Material Number (SMN): 11097635
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0496-2025·2024-11-27

    Siemens Atellica CH Cuvette Segment manufacturing defect may impact lab test accuracy

    Manufacturing defects in Siemens Atellica CH Cuvette Segments may cause inaccurate laboratory test results for seven analytes across 9,729 units.

    Product
    Siemens Atellica CH Reaction Ring Cuvette Segment-has cuvettes that contain and incubate the sample reaction volumes and present them to each processing step. Siemens Material Number(SMN): 11099326 All lots starting with N15 or 15 are expected to have the defect.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0464-2025·2024-11-20

    IMMULITE 2000 PSA assay does not meet high-dose analytical performance claim

    Siemens Healthcare is recalling certain IMMULITE 2000 PSA assay diagnostic kits because they do not perform as claimed for high-concentration samples used on IMMULITE 2000 analyzers.

    Product
    IMMULITE 2000 PSA assay, Catalog Number L2KPTS2(D) (SMN 10706281) and Catalog Number L2KPTS6(D) (SMN 10706282)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0286-2025·2024-11-13

    epoc BGEM BUN Test Cards recalled for sodium measurement bias

    Siemens recalled epoc BGEM BUN Test Cards for a negative sodium bias occurring approximately 2 months before expiration, with maximum observed bias of -10 mmol/L. No adverse events reported.

    Product
    epoc BGEM BUN Test Card (25 pk) for the epoc Blood Analysis System, SMN 10736515
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3304-2024·2024-10-09

    ADVIA Centaur aTPO Assay kits recalled due to positive result bias

    Siemens Healthcare is recalling 5,622 ADVIA Centaur aTPO Assay kits due to test accuracy issues. The affected lots produce results that are biased higher at and below the 60 U/mL threshold.

    Product
    ADVIA Centaur aTPO Assay, Material Number 10630886 (100 Test) and 10630887 (500 Test)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3305-2024·2024-10-09

    Atellica IM aTPO Assay Diagnostic Test Recalled for Measurement Bias

    Siemens Healthcare Diagnostics is recalling 9783 kits of the Atellica IM aTPO Assay diagnostic test due to positive bias in patient results below the 60 U/mL cut-off level, which may produce inaccurate test results.

    Product
    Atellica IM aTPO Assay, Material Number 10995466 (100 Test) and 10995467 (500 Test)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3170-2024·2024-09-25

    Diagnostic test reagent may produce inaccurately low patient results

    Siemens Healthcare's ADVIA Chemistry Microalbumin diagnostic test may produce falsely low results. Eight lots do not meet High-Dose Hook Effect and Prozone Effect specifications, potentially affecting microalbumin detection accuracy.

    Product
    ADVIA Chemistry Microalbumin_2 (¿ALB_2) -For in vitro diagnostic use in the quantitative measurement of microalbumin in human urine on ADVIA Chemistry systems/ Atellica CH and Atellica CI Analyzers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3169-2024·2024-09-25

    Siemens Atellica Microalbumin Diagnostic Test Kits Recalled for Measurement Error

    Siemens Healthcare Diagnostics is recalling Atellica CH and ADVIA Chemistry Microalbumin test kits worldwide because they may not properly measure microalbumin in urine samples, potentially causing falsely low results that could delay diagnosis of kidney disease.

    Product
    Atellica CH Microalbumin_2 (¿ALB_2)-For in vitro diagnostic use in the quantitative measurement of microalbumin in human urine on ADVIA Chemistry systems/ Atellica CH and Atellica CI Analyzers
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3104-2024·2024-09-18

    ADVIA Centaur CA 19-9 test kit recalled for measurement bias in samples

    Siemens Healthcare is recalling ADVIA Centaur CA 19-9 diagnostic test kits due to positive measurement bias in some samples. The affected kits may report falsely elevated test results, particularly around the normal limit of 35 U/mL.

    Product
    ADVIA Centaur CA 19-9 (250 Test)-In vitro diagnostic use in the quantitative measurement of the CA 19-9 tumor-associated antigen in human serum using the Atellica CI and Atellica IM Analyzers SMN: 10491244
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3064-2024·2024-09-18

    ADVIA Chemistry urinary protein reagent quality control failure

    Siemens Healthcare is recalling ADVIA Chemistry urinary protein test reagents due to potential quality control issues that could produce inaccurate patient results.

    Product
    ADVIA Chemistry Urinary/Cerebrospinal Fluid Protein (UCFP); Siemens Material Number (SMN): 11319151
    Category
    Medical Device
    Distribution
    Distributed nationwide