The Recall Desk

Manufacturer

Microline Surgical, Inc.

7 recalls in our database name Microline Surgical, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
7
Critical
0
Severe
0
Most recent
2024-12-18

Of the 7 recalls from Microline Surgical, Inc. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–7 of 7

  • HighFDA (Devices)·Z-0663-2025·2024-12-18

    ReNew Microscissor Tip Disposable Recalled Due to Heat Shrink Failure

    Microline Surgical is recalling ReNew Microscissor Tip (Disposable) lot 00172110 due to a 2% failure rate where the heat shrink breaks off.

    Product
    Microscissor Tip (Disposable); Microline Catalog #: 3122.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1698-2019·2019-06-12

    Microline TLS2 Thermal Ligating Shears Recalled for Actuation Failure

    Microline Surgical is recalling 115 TLS2 Thermal Ligating Shears because they fail to actuate, preventing them from performing their intended surgical function.

    Product
    TLS2 Thermal Ligating Shears, Catalog Number 132-131D
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1740-2018·2018-05-16

    Microline Surgical Recalls ReNew Dolphin Nose Disposable Dissector Tips

    Microline Surgical is recalling specific lots of ReNew Dolphin Nose Disposable Dissector Tips due to a potentially compromised sterile barrier.

    Product
    ReNew Dolphin Nose Disposable Dissector Tip, Catalog Number: 3312, UDI: 00811099011989 The ReNew single patient use disposable tips are to be used with the ReNew Laparoscopic Hand Pieces and they are indicated for cutting, grasping, dissecting and coagulation of tissue in…
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-1741-2018·2018-05-16

    Microline Surgical Recalls ReNew Endocut Scissor Tips Due to Sterility Concerns

    Microline Surgical is recalling specific lots of ReNew Endocut Scissor Disposable Tips because the sterile barrier may be compromised.

    Product
    ReNew Endocut Scissor Disposable Tip, Catalog Number: 3142, UDI: 00811099012115 The ReNew single patient use disposable tips are to be used with the ReNew Laparoscopic Hand Pieces and they are indicated for cutting, grasping, dissecting and coagulation of tissue in endoscopic…
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-0507-2018·2018-02-14

    Microline ReNew Reusable Grasper and Dissector Tips Recalled for Insulation Failure

    Microline Surgical is recalling ReNew Reusable Grasper and Dissector Tips because heat-shrink insulation may split during sterilization, posing a burn risk during surgery.

    Product
    The ReNew Reusable Grasper and Dissector Tips are to be used with the ReNew Laparoscopic Handpieces and they are indicated for cutting, grasping, dissecting, and coagulation of tissue in endoscopic and laparoscopic surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Microline Surgical (United States)

company in Beverly, United States

Country
United States
Founded
1987

Official website

Source: Wikidata (Q104481221), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.