33 recalls in our database name Medtronic MiniMed as the manufacturing or recalling firm.

What the numbers show

Total
33
Critical
0
Severe
3
Most recent
2023-01-11

Of the 33 recalls from Medtronic MiniMed we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 3 (9%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

26–33 of 33

  • HighFDA (Devices)·Z-1595-2020·2020-04-01

    Medtronic MiniMed Paradigm Veo Insulin Pumps Recalled for Cybersecurity Vulnerabilities

    Medtronic MiniMed is recalling Paradigm Veo insulin pumps due to cybersecurity vulnerabilities that could allow unauthorized wireless control of insulin delivery.

    Product
    Medtronic MiniMed Paradigm Veo Insulin pump, model numbers MMT-554 and MMT-754
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1594-2020·2020-04-01

    Medtronic MiniMed Paradigm Insulin Pump Recalled for Cybersecurity Vulnerabilities

    Medtronic MiniMed is recalling 72,850 Paradigm insulin pumps due to cybersecurity vulnerabilities that could allow unauthorized wireless control of insulin delivery.

    Product
    Medtronic MiniMed Paradigm Insulin pump, model number MMT-723
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1584-2020·2020-04-01

    Medtronic MiniMed Paradigm Insulin Pump Recalled for Cybersecurity Vulnerability

    Medtronic MiniMed is recalling 74,496 MiniMed Paradigm Insulin pumps due to cybersecurity vulnerabilities that could allow unauthorized wireless control of insulin delivery.

    Product
    MiniMed Paradigm Insulin pump, model number MMT-712
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1986-2013·2013-08-28

    Medtronic MiniMed Paradigm Reservoirs Recalled for Potential Leaking Risk

    Medtronic is recalling specific lots of Paradigm insulin reservoirs because they may leak, potentially delivering less insulin than intended.

    Product
    Medtronic MiniMed Paradigm Reservoirs, Model No: MMT-326A (1.8mL) and MMT-332A (3.0mL) The model MMT-326A and MMT-332A are syringe type insulin reservoirs intended for use with Medtronic Paradigm series insulin infusion pumps. The two reservoirs are identical except for barrel
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1668-2013·2013-07-17

    Medtronic MiniMed Paradigm Insulin Infusion Sets Recalled for Malfunction Risk

    Medtronic MiniMed is recalling Paradigm insulin infusion sets because they may malfunction and deliver incorrect insulin volumes if exposed to fluids.

    Product
    Medtronic MiniMed Paradigm Insulin Infusion Sets The Paradigm infusion sets are intended for use with Paradigm insulin infusion pumps.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1085-2013·2013-04-17

    Medtronic Recalls Paradigm Insulin Pumps Due to Cap Detachment Risk

    Medtronic is recalling Paradigm insulin infusion pumps because a drive support cap may detach and allow water to damage internal electronics.

    Product
    Medtronic MiniMed Paradigm Insulin Infusion Pumps Model Numbers: MMT-511, MMT-512, MMT-712, MMT-712E, MMT-515, MMT-715, MMT-522, MMT-522K, MMT-722, MMT-722K, MMT-523, MMT-523K, MMT-723, MMT-723K, MMT-554, and MMT-754. Product Usage: Paradigm insulin infusion pumps are inte
    Category
    Medical Device
    Distribution
    Distributed nationwide

About this company