822 recalls in our database name MEDLINE INDUSTRIES, LP - Northfield as the manufacturing or recalling firm.

What the numbers show

Total
822
Critical
9
Severe
68
Most recent
2025-10-01

Of the 822 recalls from MEDLINE INDUSTRIES, LP - Northfield we have scored against our rubric, 9 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 68 (8%) are Severe.

Which agencies issued them

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

626–650 of 822

  • HighFDA (Devices)·Z-2298-2023·2023-08-09

    Medical procedural kits recalled due to sterility concerns with ultrasound gel

    Medline recalls 76,870 procedural kits because the ultrasound gel component may not meet sterility standards. Kits were distributed nationwide and internationally from April 2020 through April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. CRMC MINOR IR PROCEDURE PK-LF, Model Numbers: DYNJ61099B, DYNJ61099C; b. CRMC TUNNEL CATH TRAY-LF, Model Numbers: DYNJ61118C, DYNJ61118F; c. CUSTOM ANGIO TRAY…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2323-2023·2023-08-09

    Medline Procedural Kits with Turkuaz Ultrasound Gel May Not Meet Sterility Requirements

    Medline is recalling 218,163 sterile procedural kits containing Turkuaz Ultrasound Gel that may not meet sterility specifications. Kits distributed April 2020-April 2023 are used in invasive medical procedures.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ADULT EPIV INSERTION TRAY, Model Number: DYNDA2482; b. ARTERIAL LINE START KIT, Model Number: ART920; c. CENTRAL LINE INSERTION TRAY, Model Number…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2311-2023·2023-08-09

    Procedural Kits Containing Ultrasound Gel Recalled for Sterility Concerns

    Medline Industries is recalling 130 custom procedural kits containing ultrasound gel that may not meet sterility specifications. The affected kits were distributed worldwide between April 2020 and April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. LIVER 2018, Model Number: DYNJ905655A;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2304-2023·2023-08-09

    Medline Procedural Kits Recalled for Potentially Non-Sterile Gel

    Medline Industries is recalling 1,218 procedural kits because the sterile ultrasound gel component may not meet sterility specifications, potentially posing an infection risk in invasive procedures.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. 16CM CENTRAL LINE BUNDLE, Model Number: STCVC2020; b. ARTERIAL LINE TRAY, Model Number: ART905; c. CATHETERLESS INSERTION KIT, Model Number: CVI4510…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2339-2023·2023-08-09

    Medline Ultrasound Gel in Surgical Kits May Not Meet Sterility Standards

    Medline is recalling approximately 9,017 breast biopsy and ultrasound surgical kits due to potential sterility failures in the included ultrasound gel component. No illnesses have been reported.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. BREAST BIOPSY KIT, Model Number: DYNDA1224A, DYNDA1224B; b. BREAST BIOPSY TRAY, Model Number: SPEC0130C; c. BREAST IMAGING TRAY, Model Number: MNS11895…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2328-2023·2023-08-09

    Medline Procedural Kit Ultrasound Gel Sterility Specification Failure

    Medline Industries is recalling procedural kits containing ultrasound gel that may not meet sterility specifications. The affected kits were distributed to healthcare facilities worldwide from 2020 to 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. DR MOTT DRAPE PACK, Model Number: DYNJ42065B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2334-2023·2023-08-09

    Medline sterile procedural kits recalled for potential sterility specification failures

    Medline is recalling custom sterile and non-sterile procedural kits containing Turkuaz Ultrasound Gel due to potential sterility specification failures. The kits were distributed worldwide to hospitals and medical facilities.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. C V MINOR PACK, Model Number: DYNJ64862A; b. DBD-C SECTION ADM, Model Number: DYKL1816; c. FETAL SURGERY, Model Number: DYNJ908118A;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2319-2023·2023-08-09

    Medline sterile procedural kits recalled for potentially non-sterile gel

    Medline is recalling 83,541 procedural kits because the included ultrasound gel component may not meet required sterility specifications.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. 7F, 20CM TRIPLE LUMEN CVC BUNDLE, Model Number: ECVC4740; b. A V GRAFT, Model Number: DYNJ36212C; c. AAA, Model Number: DYNJ905651, DYNJ905651A, DYNJ905651B…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2313-2023·2023-08-09

    Sterile Procedural Kits Recalled Due to Potential Ultrasound Gel Sterility Failure

    Medline Industries is recalling Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel because the gel component may not meet sterility specifications. The kits are distributed worldwide for dialysis procedures.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. DIALYSIS ACCESSORY PACK W/O CATHETER, Model Number: MNS10750A; b. STD INSERTION/DIALYSIS INSERTION TRAY, Model Number: CVI3845;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2333-2023·2023-08-09

    Medline Surgical Procedural Kits Recalled Due to Sterility Concerns

    Medline Industries is recalling approximately 7,462 custom surgical procedural kits containing ultrasound gel because the gel component may not meet sterility specifications. The recall affects kits distributed worldwide since April 2020.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. CHN OR DAVINCI PROSTATE, Model Number: DYNJ902540N; b. CUSTOM GYN, Model Number: DYNJ63257B; c. DBD-AMNIOCENTESIS PACK-LF, Model Number: DYNJ0771979C…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2329-2023·2023-08-09

    Ultrasound Gel in Medline Procedural Kits Recalled Over Sterility Specification Concerns

    Medline Industries recalled approximately 154,900 Custom Sterile and Non-Sterile Procedural Kits worldwide because the sterile ultrasound gel component may not meet sterility specifications.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. PROBE COVER PACK, Model Number: DYNDA1219
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2331-2023·2023-08-09

    Medline Procedural Kits Recalled Due to Sterility Specification Failure

    Medline Industries recalls 15,945 Custom Sterile and Non-Sterile Procedural Kits due to potential failure of the Turkuaz ultrasound gel component to meet sterility specifications. The kits were distributed worldwide between April 2020 and April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ANGIO, Model Number: DYNJ905151A; b. ANGIO/VENO PACK, Model Number: DYNJ58346A; c. ANGIOGRAPHIC PACK, Model Number: DYNJ57442C, DYNJ64081A; d.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2330-2023·2023-08-09

    Medline Procedural Kits Recalled for Potential Sterility Failure in Ultrasound Gel

    Medline Industries is recalling 7,040 custom sterile procedural kits containing ultrasound gel because the gel component may not meet sterility specifications, creating a potential infection risk.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. KIT TRIAGE ADMIT, Model Number: DYKA1456; b. KIT,ANTE PARTUM, Model Number: DYKL1844; c. MATERNAL ADMIT KIT, Model Number: DYKM2091
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2325-2023·2023-08-09

    Medline Procedural Kits Recalled for Potential Sterility Failure

    Medline is recalling 13,881 sterile procedural kits worldwide due to potential sterility failure in the ultrasound gel component. The affected kits are used in various medical insertion procedures.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. CVC INFANT INSERTION PACK, Model Number: CVI4770A; b. INSERTION BUNDLE, Model Number: DT21275; c. MIDLINE DRESSING CHANGE KIT, Model Number: EBSI1464…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2299-2023·2023-08-09

    Medline Procedural Kits Recalled for Ultrasound Gel Sterility Defect

    Medline Industries recalls 104,755 procedural kits due to potential sterility defect in ultrasound gel component. No illnesses or injuries have been reported.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. MULTI-LUMEN CVC BUNDLE KIT, Model Number: ECVC475; b. MULTI-LUMEN CVC INSERTION BUNDLE, Model Number: ECVC3900; c. MULTIMED 16G 1L 20CM CVC STOCK+BUNDLE US…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2301-2023·2023-08-09

    Medline Procedural Kits Recalled Due to Potential Sterility Specification Failure

    Medline is recalling 41,123 procedural kits containing ultrasound gel that may fail to meet sterility specifications. The kits were distributed to healthcare facilities worldwide between April 2020 and April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ELECTROPHYSIOLOGY PACK-LF, Model Number: DYNJ0842825D; b. EMANUEL EP TRAY, Model Number: DYNJ49933I, DYNJ49933J; c. ENDO LASER ABLATION PK-LF, Model Number…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2326-2023·2023-08-09

    FDA Recalls Medline Procedural Kits Due to Potential Sterility Failure

    Medline Industries is recalling 22 procedural kits because the included ultrasound gel may not be sterile as labeled. The kits were distributed worldwide.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. PREMIUM CLOSUREPLUS PACK, Model Number: DYNJ54326A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2317-2023·2023-08-09

    Medline Procedural Kits Recalled for Ultrasound Gel Sterility Defect

    Medline Industries recalled 11,436 procedural kits with Turkuaz ultrasound gel that may not meet sterility specifications. The affected kits were distributed worldwide from April 2020 to April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. (54) KIT STC PLASTIC FREE FLAP, Model Number: DYNJ909031; b. BREAST, Model Number: DYNJ904598B; c. BREAST DBL PROCED SUPPLEMENT, Model Number: DYNJ63893…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2227-2023·2023-08-02

    Flexible Laryngeal Mask Airway Packs Lack Required Expiration Date Labels

    Medline Industries is recalling 9,945 DYND3000xxP Series laryngeal mask airway packs because the case and packet labels are missing expiration dates. Without this information, users cannot determine product validity.

    Product
    DYND3000xxP Series - Flexible Laryngeal Mask Airway Packs
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2160-2023·2023-07-26

    Medline Probe Cover Kits Recalled for Inadequate Seam Barriers

    Medline is recalling 173,449 sterile probe cover kits due to inadequate seam barriers that may compromise sterility. The affected units were distributed worldwide between December 2017 and May 2023.

    Product
    Medline Probe Cover Kits containing sterile Ultrasound Gel, Labeled as the following: a) ANGIOGRAPHY DRAPE PACK, Model Number 00-400305R; b) ANGIO HOLLAND PACK-LF, Model Number DYNJ0037936C; c) ANGIO HOLLAND PACK-LF, Model Number DYNJ0037936D; d) ANGIOGRAM, Model Number…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2183-2023·2023-07-26

    Medline Ultrasound Probe Cover Kits Recalled for Seam Defects

    Medline is recalling ultrasound probe cover kits containing sterile ultrasound gel due to an inadequate seam barrier. The defect may compromise sterility during diagnostic ultrasound procedures.

    Product
    Medline Probe Cover Kits containing sterile Ultrasound Gel, Labeled as the following: a) IV SECUREMENT KIT, Model Number DYNDV2407A; b) USG IV START KIT, Model Number DYNDV2435; c) ULTRASOUND GUIDED IV START KIT, Model Number DYNDV2518; d) VI PACK, Model Number…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2156-2023·2023-07-26

    FDA Recalls Medline Probe Cover Kits Due to Seam Defects

    Medline is recalling probe cover kits used in diagnostic ultrasound procedures. The probe covers may have an inadequate barrier at the seams, which could compromise sterility during procedures.

    Product
    Medline Probe Cover Kits containing sterile Ultrasound Gel, Labeled as the following: a) BLOCK PACK, Model Number DYNJ81722; b) PAIN BLOCK TRAY, Model Number DYNJRA0827A; c) PAIN PREP TRAY W/PROBE COVER, Model Number DYNJRA0881; d) PAIN PREP TRAY W/PROBE COVER, Model…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2169-2023·2023-07-26

    Medline Ultrasound Probe Cover Kits recalled for inadequate seam barrier

    Medline is recalling 770,147 ultrasound probe cover kits worldwide due to inadequate barriers at the seams. The defect could allow contamination during diagnostic ultrasound procedures.

    Product
    Medline Probe Cover Kits containing sterile Ultrasound Gel, Labeled as the following: a) FETAL SURGERY CDS-LF, Model Number CDS840214Q; b) MINOR PROCEDURE TRAY, Model Number DYNDA2418; c) CLOSUREFAST PROCEDURE PACK-LF, Model Number DYNJ0365463J; d) BARIATRIC PACK, Model…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2188-2023·2023-07-26

    Medline Ultrasound Probe Cover Kits Recalled for Inadequate Seam Barriers

    Medline Industries is recalling ultrasound probe cover kits due to inadequate barriers at the seams. The defect may allow contaminants to reach the patient during diagnostic ultrasound procedures.

    Product
    Medline Probe Cover Kits containing sterile Ultrasound Gel, Labeled as the following: CHN OR DAVINCI PROSTATE, Model Number DYNJ902540N
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2164-2023·2023-07-26

    Medline Ultrasound Probe Cover Kits Recalled for Inadequate Seam Barrier

    Medline is recalling ultrasound probe cover kits containing sterile gel due to inadequate barriers at the seams, which may fail to maintain sterility during diagnostic procedures.

    Product
    Medline Probe Cover Kits containing sterile Ultrasound Gel, Labeled as the following: a) MHC VASCULAR HYBRID PK-LF, Model Number DYNJ53433K; b) VEIN SPECIALISTS PACK, Model Number DYNJ53616A; c) SUMMIT SKIN AND VEIN PACK, Model Number DYNJ54014B; d) VEIN PACK, Model Number…
    Category
    Medical Device
    Distribution
    Distributed nationwide