31 recalls in our database name Integra LifeSciences Corp. (NeuroSciences) as the manufacturing or recalling firm.

What the numbers show

Total
31
Critical
2
Severe
7
Most recent
2026-07-15

Of the 31 recalls from Integra LifeSciences Corp. (NeuroSciences) we have scored against our rubric, 2 (6%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 7 (23%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

26–31 of 31

  • SevereFDA (Devices)·Z-1958-2025·2025-07-02

    Extended Tip Applicator 8CM distributed by Integra LifeSciences recalled nationwide

    Integra LifeSciences is recalling Extended Tip Applicator 8CM devices due to potentially out-of-specification endotoxin levels and lack of sterility assurance. The recall affects 6,216 units distributed across the US and internationally.

    Product
    Extended Tip Applicator, 8CM, Box of 5.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1960-2025·2025-07-02

    Extended Tip Applicator 8CM medical devices recalled due to sterility concerns

    Integra LifeSciences is recalling Extended Tip Applicator 8CM devices nationwide and internationally because they may contain potentially out-of-specification endotoxin levels and lack sterility assurance.

    Product
    Extended Tip Applicator 8CM, Box of 1.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1959-2025·2025-07-02

    Extended Tip Applicator 15 CM recalled for endotoxin and sterility issues

    Integra LifeSciences is recalling Extended Tip Applicators (15 CM, Box of 5) because they may contain out-of-specification levels of endotoxins and lack sterility assurance.

    Product
    Extended Tip Applicator, 15 CM, Box of 5.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1717-2025·2025-05-14

    CODMAN Craniotomy Kit Cranial Perforator Disposed Over Weld Defect

    Integra LifeSciences is recalling CODMAN Craniotomy Kits due to inadequate welds that may cause the product to disassemble. The defect affects 1,840 units distributed worldwide.

    Product
    CODMAN Craniotomy Kit, Disposable Perforator Cranio-blade Wire Pass Drill, 14mm. Cranial perforator kit.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1716-2025·2025-05-14

    CODMAN Disposable Cranial Perforator 14mm Recalled Due Weld Issue

    Integra LifeSciences is recalling CODMAN Disposable Perforators (14mm) due to inadequate welds that could cause disassembly during use. The affected devices have been distributed worldwide.

    Product
    CODMAN Disposable Perforator, 14mm. Cranial perforator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1724-2025·2025-05-14

    INSPIRA AIR Balloon Dilation System packaging error corrected nationwide

    Integra LifeSciences is recalling INSPIRA AIR Balloon Dilation System 10x40 cartons because an incorrect product was packaged inside. The recall affects six units distributed across Texas, Montana, Alabama, and Oklahoma.

    Product
    INSPIRA AIR BALLOON DILATION SYSTEM 10x40, 1 PK. Airway balloon dilation catheter.
    Category
    Medical Device
    Distribution
    Distributed nationwide