The Recall Desk

Manufacturer

Icotec Ag

3 recalls in our database name Icotec Ag as the manufacturing or recalling firm.

What the numbers show

Total
3
Critical
0
Severe
0
Most recent
2024-01-17

Of the 3 recalls from Icotec Ag we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–3 of 3

  • HighFDA (Devices)·Z-0701-2024·2024-01-17

    VADER Pedicle System Torque Wrench Recalled Due to Defective Tightening Function

    Icotec is recalling VADER pedicle system torque wrenches because the torque limiting function can malfunction, potentially leaving screw fasteners insufficiently tightened during implant surgery.

    Product
    VADER pedicle system, torque wrench, Catalog Number 42-703
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-0700-2024·2024-01-17

    VADER pedicle system torque wrench may not tighten implant screws correctly

    Icotec Ag is recalling VADER pedicle system torque wrenches (Catalog Number 42-702) because the torque limiting function may malfunction, potentially leaving nut screws insufficiently tightened during implant surgery. No injuries have been reported.

    Product
    VADER pedicle system, torque wrench, Catalog Number 42-702
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-0728-2023·2022-12-28

    VADER Pedicle System Torque Wrench Recalled for Out-of-Specification Calibration

    Icotec Ag is recalling six VADER Pedicle System Torque Wrench devices due to a calibration error where the torque limiting function was found to be out of specification, delivering 4 Nm instead of the specified 12 Nm.

    Product
    VADER Pedicle System Torque Wrench, Hudson Coupling, 12 Nm, REF 42-702
    Category
    Medical Device
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

icotec ag (Switzerland)

company in Altstätten, Switzerland

Country
Switzerland
Founded
1999

Official website