9 recalls in our database name CardioQuip, LLC as the manufacturing or recalling firm.

What the numbers show

Total
9
Critical
0
Severe
0
Most recent
2023-12-27

Of the 9 recalls from CardioQuip, LLC we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–9 of 9

  • HighFDA (Devices)·Z-0566-2024·2023-12-27

    CardioQuip Modular Cooler-Heater Model MCH-1000(m) Recalled for Bacterial Contamination

    CardioQuip LLC is recalling 2 units of its Model MCH-1000(m) Modular Cooler-Heater due to potential bacterial contamination that could result in patient infection. The affected devices are distributed in California, Texas, Pennsylvania, Washington, Ohio, and Nebraska.

    Product
    CardioQuip Modular Cooler-Heater, Model: MCH-1000(m), Power: 115V-60Hz, 16A
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-0565-2024·2023-12-27

    CardioQuip Modular Cooler-Heater Device Recalled for Potential Bacterial Contamination

    CardioQuip is recalling the Modular Cooler-Heater (Model MCH-1000i) due to potential bacterial contamination that could cause patient infection. Four units were distributed in California, Texas, Pennsylvania, Washington, Ohio, and Nebraska.

    Product
    CardioQuip Modular Cooler-Heater, Model: MCH-1000(i), Power: 115V-60Hz, 16A
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-0438-2024·2023-12-13

    CardioQuip Modular Cooler-Heater heating chamber malfunction poses burn risk

    CardioQuip is recalling 150 units of its Modular Cooler-Heater (Model MCH-1000m) due to potential heating-chamber malfunction that could cause component melting or burning. The device may overheat unexpectedly.

    Product
    CardioQuip Modular Cooler-Heater, Model:MCH-1000(m), Power: 115V-60hz,16A
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-0439-2024·2023-12-13

    CardioQuip Modular Cooler-Heater Units Recalled for Heating Chamber Malfunction

    CardioQuip Modular Cooler-Heater units are being recalled due to a potential heating-chamber malfunction that could cause melting and burning of internal components. 125 units distributed across 15 US states are affected.

    Product
    CardioQuip Modular Cooler-Heater, Model:MCH-1000(i), Power: 115V-60hz,16A
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-0035-2022·2021-10-13

    CardioQuip Modular Cooler-Heater Devices Recalled for Missing Maintenance Guidance

    CardioQuip is recalling 1,478 Modular Cooler-Heater devices because the labeling does not include proper water-quality maintenance and device inspection guidance.

    Product
    CardioQuip, Modular Cooler-Heater, Model: MCH-1000(i), CE 2797, UDI: (01)00860000846103
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0036-2022·2021-10-13

    CardioQuip Cooler-Heater Device Lacks Water-Quality and Inspection Guidance

    FDA recalls 1,380 CardioQuip Modular Cooler-Heater 1000(i) devices worldwide due to labeling missing guidance on water-quality maintenance and device inspection procedures.

    Product
    CardioQuip, Modular Cooler-Heater 1000(i), Standard Unit, Model: MCH-10RMS, CE 2797, UDI: (01) 00860000846127
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0069-2022·2021-10-13

    CardioQuip Modular Cooler-Heater Units Recalled for Bacterial Water Contamination

    CardioQuip heater-cooler refrigeration modules used in operating rooms could develop bacterial contamination in water systems, potentially exposing patients to infection during surgery.

    Product
    CardioQuip, Modular Cooler-Heater 1000(i), Refrigeration Module, Model: MCH-10RMS, UDI: (01)00860000846127 used with heat exchange devices.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0037-2022·2021-10-13

    Medical cooler-heater device recalled for inadequate maintenance and inspection guidance

    CardioQuip is recalling 1,646 units of its Modular Cooler-Heater 1000(m) due to inadequate labeling. The device documentation lacks guidance on proper water-quality maintenance and inspection procedures required for safe operation.

    Product
    CardioQuip, Modular Cooler-Heater 1000(m),Compact Unit, Model:MCH-1000(m),CE 2797, UDI: (01)00860000846110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0038-2022·2021-10-13

    Cardiac Cooler-Heater Device Lacks Maintenance and Inspection Guidance

    CardioQuip is recalling its Modular Cooler-Heater device because labeling omits proper guidance for water-quality maintenance and device inspection, affecting users' ability to maintain the device correctly.

    Product
    CardioQuip, Modular Cooler-Heater 1000(m),Thermoelectric Cooling Lid, Model: MCH-11TEC,CE 2797, UDI: (01) 00860000846134
    Category
    Medical Device
    Distribution
    Distributed nationwide