The Recall Desk

Manufacturer

Becton, Dickinson and Company

4 recalls in our database name Becton, Dickinson and Company as the manufacturing or recalling firm.

What the numbers show

Total
4
Critical
0
Severe
1
Most recent
2026-09-30

Of the 4 recalls from Becton, Dickinson and Company we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1 (25%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–4 of 4

  • HighFDA (Devices)·Z-3250-2026·2026-09-30

    Becton, Dickinson ForeSight Elite Tissue Oximetry Cable Recall for Incorrect Channel Switching

    Becton, Dickinson and Company is recalling 15,455 ForeSight Elite Tissue Oximetry Cables due to incorrect switching of Channel 1 and 2 on the module and flag labels.

    Product
    ForeSight Elite Tissue Oximetry Cable REF HEMFSM10 UDI-DI code: 00690103210927 The non-invasive ForeSight oximeter cable is intended for use as an adjunct monitor of absolute regional hemoglobin oxygen saturation of blood under the sensors in individuals at risk for reduced…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2202-2026·2026-05-27

    Swan-Ganz Catheters Models 131F7 Through AIQSGF8 Recalled Nationwide

    Becton, Dickinson and Company is recalling multiple models of Swan-Ganz Catheters due to potential leaking or breaking of the proximal injectate lumen hub that could lead to infection, medication loss, or blood loss.

    Product
    Swan-Ganz Catheter, Models: 131F7/131F7P, 131F7J, 141F7, 151F7, 834F75, 096F6/096F6P, C144F7, 782F75M, 132F5, C146F7, 831F75/831F75P, TS105F5, 774F75, 777F8, AIQSGF8;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2203-2026·2026-05-27

    Swan-Ganz Jr Catheter models recalled due to lumen hub leakage

    Becton, Dickinson and Company is recalling Swan-Ganz Jr Catheters (models SGPT54, SGPT64P, SGPT755P) because the blue proximal injectate lumen hub may leak or break due to manufacturing changes, risking infection, medication loss, and blood loss.

    Product
    Swan-Ganz Jr Catheter, Models: SGPT54, SGPT64P, SGPT755P
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2204-2026·2026-05-27

    Swan-Ganz Pacing Catheter Model D200F7 Recall Due to Leak Risk

    Becton, Dickinson and Company is recalling Swan-Ganz Pacing Catheter Model D200F7 due to a manufacturing defect that may cause the proximal injectate lumen hub to leak or break, potentially leading to infection, medication loss, or blood loss.

    Product
    Swan-Ganz Pacing Catheter, Models: D200F7;
    Category
    Medical Device
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Becton Dickinson

American multinational medical technology company

Country
United States
Founded
1897

Official website