The Recall Desk

Manufacturer

AVID Medical, Inc.

207 recalls in our database name AVID Medical, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
207
Critical
7
Severe
21
Most recent
2026-10-14

Of the 207 recalls from AVID Medical, Inc. we have scored against our rubric, 7 (3%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 21 (10%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

126–150 of 207

  • HighFDA (Devices)·Z-0385-2025·2024-11-20

    Medical Surgical Kit Recalled for Potential Loose Metal Flake Hazard

    AVID Medical recalls Halyard D & C surgical convenience kits due to potential metal flakes that could detach from forceps and clamps. Affected lot 1596759 was distributed nationwide.

    Product
    Halyard D & C PACK-CKC - Medical convenience kits Model Number: BMGT003-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0383-2025·2024-11-20

    Medical Drainage Pack Components Recalled for Potential Metal Fragments

    AVID Medical is recalling the Halyard IR Abcess Drainage Pack due to sponge forceps and towel clamps that may have loose metal flakes. Metal flakes could detach and enter a patient's surgical site, causing local or foreign body reactions.

    Product
    Halyard IR ABCESS DRAINAGE PACK - Medical convenience kits Model Number: AVMD018
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0445-2025·2024-11-20

    AVID Medical Recalls Halyard Surgical Kits Due to Metal Flakes

    AVID Medical is recalling Halyard SPECIALS PACK medical convenience kits because sponge forceps and towel clamps may release metal flakes that could enter a patient's surgical site.

    Product
    Halyard SPECIALS PACK - Medical convenience kits Model Number: VAST031-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0394-2025·2024-11-20

    Medical surgical kits recalled due to loose metal flakes

    AVID Medical is recalling Halyard TOTAL KNEE surgical kits (Model EUOR002-05) because sponge forceps and towel clamps may shed small metal flakes that could contaminate surgical sites and cause reactions.

    Product
    Halyard KIT, TOTAL KNEE - Medical convenience kits Model Number: EUOR002-05
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0401-2025·2024-11-20

    Halyard TOTAL KNEE Medical Convenience Kits Recalled for Loose Metal Flakes

    AVID Medical is recalling Halyard TOTAL KNEE kits because sponge forceps and towel clamps may have loose metal flakes that could detach and enter a patient's surgical site, causing local or foreign body reactions.

    Product
    Halyard TOTAL KNEE - Medical convenience kits Model Number: GRND008-09
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0408-2025·2024-11-20

    Surgical Instruments Recalled Due to Potential Metal Flake Contamination

    AVID Medical recalled Halyard POST PARTUM TUBAL LIGATION surgical kit components due to loose metal flakes that could detach from sponge forceps and towel clamps. Metal flakes entering a patient's surgical site could cause local or foreign body reactions.

    Product
    Halyard POST PARTUM TUBAL LIGATION - Medical convenience kits Model Number: LANC026-19
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0423-2025·2024-11-20

    Halyard Laparotomy GYN Packs recalled due to loose metal flakes

    AVID Medical recalls Halyard LAPAROTOMY GYN surgical packs due to loose metal flakes on sponge forceps and towel clamps. Metal fragments may enter the surgical site and cause local or foreign body reactions.

    Product
    Halyard LAPAROTOMY GYN PACK - Medical convenience kits Model Number: SAMM018-13
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0446-2025·2024-11-20

    Halyard EP TRAY Surgical Kits Recalled for Loose Metal Flakes

    AVID Medical is recalling Halyard EP TRAY surgical convenience kits due to sponge forceps and towel clamps that may shed small metal flakes. These flakes could enter surgical sites, potentially causing local or foreign body reactions.

    Product
    Halyard EP TRAY - Medical convenience kits Model Number: VAST038-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0433-2025·2024-11-20

    Surgical forceps and clamps recalled due to detachable metal flakes

    AVID Medical is recalling Halyard CPT surgical convenience kits because sponge forceps and towel clamps may shed small metal flakes that could contaminate surgical sites. No illnesses have been reported.

    Product
    Halyard CPT PEDS ADULT CH PACK - Medical convenience kits Model Number: SHAN431-07
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0413-2025·2024-11-20

    Halyard Pacemaker Pack surgical kits recalled for loose metal flakes

    AVID Medical is recalling Halyard Pacemaker Pack surgical kits because sponge forceps and towel clamps contain loose metal flakes that could detach and enter patient surgical sites.

    Product
    Halyard PACEMAKER PACK - Medical convenience kits Model Number: MAMC223-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0410-2025·2024-11-20

    Halyard Knee Arthroscopy Packs recalled due to loose metal flakes

    AVID Medical recalls Halyard Knee Arthroscopy Packs due to loose metal flakes that could detach from forceps and clamps. Metal fragments may enter the surgical site, potentially causing local or foreign body reactions.

    Product
    Halyard KNEE ARTHROSCOPY PACK - Medical convenience kits Model Number: MAMC204-16
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0435-2025·2024-11-20

    Halyard C Section Pack surgical kits recalled for loose metal flakes

    AVID Medical is recalling Halyard C Section Pack surgical kits due to loose metal flakes on sponge forceps and towel clamps. These flakes may enter a surgical site and cause local reactions or foreign body complications.

    Product
    Halyard C SECTION PACK - Medical convenience kits Model Number: SJCS66-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0455-2025·2024-11-20

    Halyard ANGIO PACK surgical kits recalled for loose metal fragments

    AVID Medical recalls Halyard ANGIO PACK surgical kits due to loose metal flakes that could detach and enter a patient's surgical site. The recall affects 284 units distributed nationwide.

    Product
    Halyard ANGIO PACK - Medical convenience kits Model Number: WRNM047-05
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0396-2025·2024-11-20

    Halyard SPINE Kit recalled for loose metal flakes in surgical instruments

    AVID Medical is recalling Halyard SPINE surgical kits (Model EUOR004-02) due to loose metal flakes that may detach from sponge forceps and towel clamps. These flakes could potentially enter a patient's surgical site, causing local or foreign body reactions.

    Product
    Halyard KIT, SPINE - Medical convenience kits Model Number: EUOR004-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0431-2025·2024-11-20

    Halyard CPT Cardiac Cath Pack Recalled Due to Loose Metal Flakes in Forceps and Clamps

    AVID Medical is recalling Halyard CPT Cardiac Cath Pack convenience kits due to small metal flakes that may detach from sponge forceps and towel clamps. Metal flakes could enter a surgical site undetected and cause local or foreign body reactions.

    Product
    Halyard CPT CARDIAC CATH PACK - Medical convenience kits Model Number: SHAN430-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0399-2025·2024-11-20

    Surgical instrument kits recalled for potential loose metal flake hazard

    Halyard abdominal procedure surgical kits may contain loose metal flakes in forceps and clamps that could enter the surgical site. Affected kits have lot number 1590888.

    Product
    Halyard ABDOMINAL PROCEDURE - Medical convenience kits Model Number: GRAN015-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0438-2025·2024-11-20

    Surgical instruments recalled for loose metal flake contamination risk

    AVID Medical is recalling Halyard RAD PACK medical convenience kits containing sponge forceps and towel clamps. Small metal flakes may detach and enter surgical sites, potentially causing foreign body or local tissue reactions.

    Product
    Halyard RAD PACK - Medical convenience kits Model Number: VANW017-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0405-2025·2024-11-20

    Halyard GYN TRAY surgical kits recalled for loose metal flakes

    AVID Medical is recalling 136 units of Halyard GYN TRAY surgical kits due to small loose metal flakes that could detach from sponge forceps and towel clamps. These metal fragments could enter a patient's surgical site undetected, causing local or foreign body reactions.

    Product
    Halyard GYN TRAY - Medical convenience kits Model Number: LANC014-19
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0453-2025·2024-11-20

    Halyard Pacemaker Tray Surgical Kits Recalled for Loose Metal Flakes

    AVID Medical recalls Halyard PACEMAKER TRAY surgical kits nationwide due to potential loose metal flakes that could detach from sponge forceps and towel clamps and contaminate surgical sites.

    Product
    Halyard PACEMAKER TRAY - Medical convenience kits Model Number: VMPB0003-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0391-2025·2024-11-20

    Halyard Shoulder Medical Kit recalled for loose metal flakes in surgical components

    AVID Medical is recalling Halyard shoulder surgical kits due to loose metal flakes that could detach and enter surgical sites. Metal debris could cause local or foreign body reactions.

    Product
    Halyard KIT, SHOULDER - Medical convenience kits Model Number: ESJH014-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0418-2025·2024-11-20

    AVID Medical Recalls Heart Cath Lab Kits Due to Metal Flakes

    AVID Medical is recalling 411 Heart Cath Lab Kits because sponge forceps and towel clamps may release metal flakes that could enter a patient's surgical site.

    Product
    Halyard HEART CATH LAB PK, STRL F G - Medical convenience kits Model Number: MSBM003-03
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0447-2025·2024-11-20

    Halyard Angiography Drape Pack Recalled for Potential Metal Flakes in Surgical Site

    AVID Medical recalls Halyard angiography drape packs due to potential metal flakes that could detach from sponge forceps and towel clamps. These flakes could enter a surgical site undetected and cause local or foreign body reactions.

    Product
    Halyard ANGIOGRAPHY DRAPE PACK - Medical convenience kits Model Number: VMCC021-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0448-2025·2024-11-20

    Medical Convenience Kits Recalled for Potential Loose Metal Flakes in Surgical Instruments

    AVID Medical is recalling Halyard MANIFOLD CATH PACK medical convenience kits because sponge forceps and towel clamps may shed metal flakes that could contaminate surgical sites.

    Product
    Halyard MANIFOLD CATH PACK - Medical convenience kits Model Number: VMED005-03
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0434-2025·2024-11-20

    Surgical instrument kits recalled for loose metal flakes

    AVID Medical is recalling Halyard CPT EP PACK surgical convenience kits due to loose metal flakes on forceps and towel clamps. Detached metal flakes could enter surgical sites and potentially cause local tissue reactions or foreign body complications.

    Product
    Halyard CPT EP PACK - Medical convenience kits Model Number: SHAN442-04
    Category
    Medical Device
    Distribution
    Distributed nationwide