The Recall Desk

Manufacturer

Atrium Medical Corporation

153 recalls in our database name Atrium Medical Corporation as the manufacturing or recalling firm.

What the numbers show

Total
153
Critical
2
Severe
4
Most recent
2026-09-16

Of the 153 recalls from Atrium Medical Corporation we have scored against our rubric, 2 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 4 (3%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

26–50 of 153

  • HighFDA (Devices)·Z-1975-2024·2024-06-12

    ADVANTA VXT vascular graft recalled for swivel rod separation

    Atrium Medical recalls ADVANTA VXT vascular grafts due to reports of swivel rod separation from the swivel core. Affected units distributed worldwide; healthcare providers should evaluate appropriate management.

    Product
    ADVANTA VXT, 6X50, 1GDS, NH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2017-2024·2024-06-12

    Vascular graft device recalled due to swivel rod separation

    Atrium Medical Corporation is recalling FLIXENE vascular grafts due to reported separation of the swivel rod from the core component. This defect could compromise device function.

    Product
    FLIXENE, 4-7X45, 2GDS, GWT-GW. Double-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2002-2024·2024-06-12

    Vascular graft separation risk affects FLIXENE slider GDS devices

    Atrium Medical recalls FLIXENE vascular grafts due to complaints of slider rod separation from the swivel core, which could affect device function.

    Product
    FLIXENE, 6X50, 1GDS, GW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1951-2024·2024-06-12

    FDA Recalls Atrium Medical Vascular Graft for Slider Separation Defect

    Atrium Medical is recalling ADVANTA VXT vascular grafts due to reports of the slider rod separating from the swivel core, which could impair proper device function.

    Product
    ADVANTA VXT, 5X40, 1GDS, NH, STR-SW. Single-Ended Slider. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2011-2024·2024-06-12

    Vascular Graft Component Separation Risk Triggers Worldwide Device Recall

    Atrium Medical recalls FLIXENE vascular grafts due to reported separation of the Swivel Rod from the Swivel Core, creating gaps that could affect device function. Over 53,000 units worldwide are affected.

    Product
    FLIXENE, 6X30, 1GDS, STR. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2005-2024·2024-06-12

    FLIXENE Vascular Graft Recalled for Slider Swivel Rod Separation

    Atrium Medical Corporation is recalling FLIXENE vascular grafts due to reports of the slider swivel rod separating from the swivel core. The separation could affect device function during vascular procedures.

    Product
    FLIXENE, 7X40, 1GDS, GW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1977-2024·2024-06-12

    Vascular graft slider component separation reported in ADVANTA VXT

    Atrium Medical Corporation is recalling ADVANTA VXT vascular grafts due to separation of the Slider GDS Swivel Rod from the Swivel Core. Over 53,000 units affected worldwide.

    Product
    ADVANTA VXT, 6X70, 1GDS, NH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2006-2024·2024-06-12

    Vascular graft component separation reported in FLIXENE Slider GDS devices

    Atrium Medical Corporation is recalling FLIXENE vascular grafts due to reported separation between the Slider GDS Swivel Rod and Swivel Core, affecting 53,308 units distributed worldwide.

    Product
    FLIXENE, 7X80, 1GDS, GW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1990-2024·2024-06-12

    Vascular graft separation issue prompts FDA recall of Atrium Medical ADVANTA VXT units

    Atrium Medical Corporation is recalling its ADVANTA VXT vascular grafts due to complaints of swivel rod separation from the swivel core, which could affect device function and patient safety.

    Product
    ADVANTA VXT, 8X80, 1GDS, FH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1984-2024·2024-06-12

    Vascular graft separation reported in ADVANTA VXT medical devices

    Atrium Medical Corporation is recalling ADVANTA VXT vascular grafts due to reported separation of the Slider GDS Swivel Rod from the Swivel Core. Approximately 53,308 units have been affected worldwide.

    Product
    ADVANTA VXT, 7X50, 1GDS, FH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1978-2024·2024-06-12

    ADVANTA VXT Vascular Graft Recalled for Component Separation

    ADVANTA VXT vascular grafts are recalled due to reported separation of the Slider GDS Swivel Rod from the Swivel Core, creating a gap between components.

    Product
    ADVANTA VXT, 7X70, 1GDS, NH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1996-2024·2024-06-12

    ADVANTA VXT Vascular Grafts Recalled for Slider Component Separation Risk

    Atrium Medical Corporation is recalling ADVANTA VXT vascular grafts due to reported separation of the Slider GDS Swivel Rod from the Swivel Core. Approximately 53,308 units worldwide are affected.

    Product
    ADVANTA VXT, 4-7X70, 1GDS, NH, TPR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1985-2024·2024-06-12

    Vascular Graft Swivel Rod Separation Recalled Due to Component Failure

    Atrium Medical Corporation is recalling ADVANTA VXT vascular grafts due to reports of separation between the Slider GDS Swivel Rod and Swivel Core, which could affect device function.

    Product
    ADVANTA VXT, 8X50, 1GDS, FH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1997-2024·2024-06-12

    Vascular Graft Component Separation in ADVANTA VXT Medical Devices

    ADVANTA VXT vascular grafts are being recalled because the Slider GDS Swivel Rod may separate from the Swivel Core. This affects about 53,308 units distributed worldwide including the US.

    Product
    ADVANTA VXT, 4-7X45, 2GDS, NH, TPR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1994-2024·2024-06-12

    Vascular graft recalled due to slider component separation risk

    Atrium Medical's ADVANTA VXT vascular grafts are being recalled worldwide due to reports of the Slider GDS Swivel Rod separating from the Swivel Core. The separation creates a gap that could compromise device function.

    Product
    ADVANTA VXT, 4-7X45, 1GDS, NH, TPR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1957-2024·2024-06-12

    Vascular graft recalled due to slider component separation risk

    Atrium Medical is recalling ADVANTA VXT vascular grafts due to reports of the slider GDS swivel rod separating from the swivel core. Approximately 53,308 units are affected worldwide.

    Product
    ADVANTA VXT, 8X50, 1GDS, NH, STR-SW. Single-Ended Slider. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1970-2024·2024-06-12

    Vascular graft recalled for slider rod component separation

    Atrium Medical is recalling ADVANTA VXT vascular grafts due to reported separation of the Slider GDS Swivel Rod from its Swivel Core. The recall affects 53,308 units distributed worldwide.

    Product
    ADVANTA VXT, 8X70, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1973-2024·2024-06-12

    Atrium ADVANTA VXT Vascular Graft Slider Rod Separation

    ADVANTA VXT vascular grafts may have separation of the Slider GDS Swivel Rod from the Swivel Core. Atrium is recalling affected units.

    Product
    ADVANTA VXT, 6X40, 1GDS, NH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1967-2024·2024-06-12

    ADVANTA VXT vascular graft slider component separation recall

    ADVANTA VXT vascular grafts may experience separation of the slider component from its core. This Class II recall affects 53,308 units distributed worldwide.

    Product
    ADVANTA VXT, 8X50, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1963-2024·2024-06-12

    Atrium Medical Vascular Graft Swivel Component Separation Recall

    Atrium Medical recalled 53,308 ADVANTA VXT vascular grafts worldwide due to reported separation of the swivel rod from the swivel core. The affected units were distributed throughout the United States and to 60 additional countries.

    Product
    ADVANTA VXT, 6X40, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2004-2024·2024-06-12

    Vascular graft recalled for separation of slider mechanism

    Atrium Medical Corporation recalls FLIXENE vascular grafts due to separation of the slider swivel rod from the core assembly. The device defect affects 53,308 units distributed worldwide.

    Product
    FLIXENE, 6X40, 1GDS, GW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1959-2024·2024-06-12

    ADVANTA VXT Vascular Graft Recalled for Slider Rod Separation

    The ADVANTA VXT vascular graft is being recalled because its slider rod can separate from the swivel core, creating a gap between components. No injuries have been reported.

    Product
    ADVANTA VXT, 6X70, 1GDS, NH, STR-SW. Single-Ended Slider. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1971-2024·2024-06-12

    ADVANTA VXT Vascular Grafts Recalled for Slider Rod Separation

    Atrium Medical is recalling 53,308 ADVANTA VXT vascular grafts worldwide due to reported separation of the slider rod from the swivel core, with a gap observed between the components.

    Product
    ADVANTA VXT, 6X80, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1966-2024·2024-06-12

    ADVANTA VXT Vascular Graft Slider Component Separation Recall

    Atrium Medical Corporation is recalling its ADVANTA VXT vascular graft due to reports that the Slider GDS Swivel Rod can separate from the Swivel Core, creating a gap between components.

    Product
    ADVANTA VXT, 7X50, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2016-2024·2024-06-12

    FLIXENE Vascular Graft Recalled for Slider Component Separation

    Atrium Medical is recalling the FLIXENE vascular graft due to reported separation of the Slider GDS Swivel Rod from its core. Component separation could affect graft function.

    Product
    FLIXENE, 4-6X45, 2GDS, GWT-GW. Double-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

ATRIUM MEDICAL CORPORATION

Source: Wikidata (Q139903018), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.