The Recall Desk

Hazard

Unsterilized Device recalls

3 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
3
Critical
0
Severe
0
Most recent
2024-03-13

Of the 3 unsterilized device recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all unsterilized device recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–3 of 3

  • HighFDA (Devices)·Z-1255-2024·2024-03-13

    Paragon 28 Phantom TTC Nail recalled for unsterilized distribution

    Paragon 28, Inc. is recalling the Phantom TTC Nail (10.0 X 150mm, RIGHT) distributed in California, as these devices were shipped prior to sterilization. Unsterilized surgical implants pose a serious risk of infection and complications.

    Product
    Phantom TTC Nail, TTC Nail, 10.0 X 150mm, RIGHT , REF: P31-600-175L
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1822-2022·2022-10-05

    Humidifier Bottle and Syringe Filter Kit Sterile Barrier Breach Recall

    CooperSurgical is recalling BT37 benchtop incubator humidifier and filter kits due to a potential sterile barrier breach. The defect may allow unsterilized devices to contaminate and degrade embryos during incubation.

    Product
    Humidifier bottle and syringe filter kit (6 count of each) for the BT37 Mark I Benchtop Incubator (AY102295). The Mark I model is no longer produced, but the legacy humidifier bottle component design can also be used with the BT37 Mark II Benchtop Incubator.
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0998-2015·2015-01-28

    Cordis POWERFLEX PRO PTA Dilatation Catheter Recall for Unsterilized Unit

    Cordis Corporation is recalling one unsterilized unit of the POWERFLEX PRO PTA Dilatation Catheter from a demonstration lot left at a hospital.

    Product
    Cordis POWERFLEX PRO PTA Dilatation Catheter Intended to dilate stenoses in iliac, femoral, ilio-femoral, popliteal, infra popliteal and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. The device is also…
    Category
    Medical Device
    Distribution