The Recall Desk

Hazard

Surgical Intervention Required recalls

6 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
6
Critical
0
Severe
2
Most recent
2024-05-15

Of the 6 surgical intervention required recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2 (33%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all surgical intervention required recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–6 of 6

  • HighFDA (Devices)·Z-1767-2024·2024-05-15

    FDA Recalls Vascular Access Device Due to Loose Metal Shavings Risk

    Angiodynamics' DURAMAX STACKED TIP vascular access device may contain loosely affixed metal shavings that could cause blood vessel blockage, potentially requiring surgical removal.

    Product
    DURAMAX STACKED TIP 24CM STR. BASIC KIT, 5-UP PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103028035
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0908-2023·2023-01-18

    Philips Fetal Spiral Electrode may break off during labor monitoring

    Philips is recalling fetal spiral electrodes used for labor monitoring because the spiral tip can break off during use, requiring surgery to remove the fragment from the newborn.

    Product
    Philips Fetal Spiral Electrode-intended for patients requiring fetal heart rate monitoring during labor. PN: 989803137631
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0225-2023·2022-11-16

    ORISE Gel Syringe Recall Due to Foreign Body Reaction Risk

    Boston Scientific has recalled ORISE Gel Syringe kits used in gastrointestinal endoscopy due to higher incidence of foreign body reactions from remnant gel requiring surgical intervention.

    Product
    ORISE Gel Syringe Submucosal Lifting Agent Kits: indicated for use in gastrointestinal endoscopic procedures for submucosal lift of polyps, adenomas, early-stage cancers or other gastrointestinal mucosal lesions, prior to excision with a snare or other suitable endoscopic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2262-2021·2021-08-18

    Hip Replacement Component Recalled for Potential Device Failure Risk

    Biomet is recalling 81 units of a hip replacement component due to potential device failure that could require additional surgery. The affected device is the Arcos Modular Revision Hip System High Offset Cone Prox Body, Size A.

    Product
    Arcos Modular Revision Hip System High Offset Cone Prox Body, Size A, 50 MM Item Number: 11-301310
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2268-2021·2021-08-18

    Arcos Hip System Cones Recalled for Potential Inner Taper Corrosion

    Biomet recalled 11 Arcos Modular Revision Hip System proximal cones due to potential inner taper fretting corrosion and device failure that could require surgical intervention. Affected units distributed nationwide.

    Product
    Arcos Modular Revision Hip System Standard Cone Prox Body, Size B, 70 MM Item Number: 11-301322
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2267-2021·2021-08-18

    Biomet Arcos Hip Implant Component Recalled for Potential Fretting Corrosion

    Biomet is recalling 11 units of Arcos Modular Revision Hip System Standard Cone Prox Body components due to potential fretting corrosion at the inner taper joint that could cause device failure and require revision surgery.

    Product
    Arcos Modular Revision Hip System Standard Cone Prox Body, Size A, 70 MM Item Number: 11-301321
    Category
    Medical Device
    Distribution
    Distributed nationwide