The Recall Desk

Hazard

Result Delay recalls

33 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
33
Critical
0
Severe
0
Most recent
2026-07-15

Of the 33 result delay recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all result delay recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–33 of 33

  • ModerateFDA (Devices)·Z-2266-2025·2025-08-13

    UniCel DxI 800 analyzer motor current resets below the required setting

    UniCel DxI 800 Access Immunoassay Analyzers are being recalled because software overwrites the factory PnP X-motor current setting, causing increased motion errors that could delay patient results. 2,203 systems affected.

    Product
    UniCel DxI 800 Access Immunoassay Analyzer, Part Number 973100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2269-2025·2025-08-13

    UniCel DxI 600 analyzer motor current resets below the required setting

    UniCel DxI 600 Access Immunoassay Analyzers are being recalled because software overwrites the factory PnP X-motor current setting, causing increased motion errors. 271 systems are affected.

    Product
    UniCel DxI 600 Access Immunoassay Analyzer, Part Number A30260
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2267-2025·2025-08-13

    DxI 800 immunoassay analyzer motor current resets below the required setting

    A DxI 800 Access Immunoassay Analyzer is being recalled because software overwrites the factory PnP X-motor current setting, causing increased motion errors that could delay patient results.

    Product
    DxI 800 Access Immunoassay Analyzer W/Dual Gantry, Part Number A71457
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2073-2025·2025-07-09

    VITROS opiate reagent lots may give low quality control results

    VITROS Chemistry Products OP Reagent Gen 15 lots are being recalled because they may generate lower than expected quality control results. 2,017 units are affected.

    Product
    VITROS Chemistry Products OP Reagent Gen 15. Model Number: 680 1997. The VITROS OP Reagent is a dual-chambered package containing ready-to-use liquid reagents that are used to detect opiates in urine. One sales unit contains 6 Microtip packs of reagent. Each pack has 50 OP…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1913-2025·2025-06-11

    DxI 9000 Access Immunoassay Analyzer Software Update Error Codes

    Beckman Coulter is recalling DxI 9000 Access Immunoassay Analyzers running software version 1.20 because the update introduces error codes that prevent assays from being performed and may delay result generation.

    Product
    DxI 9000 Access Immunoassay Analyzer, Catalog Number C11137, running software version 1.20
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1115-2025·2025-02-12

    Beckman Coulter DxI 9000 immunoassay analyzer recalled for software-related motion errors

    Beckman Coulter is recalling 61 DxI 9000 immunoassay analyzers worldwide due to a software error causing tray gripper motion errors that result in intermittent hard stops and delays in patient test results.

    Product
    Beckman Coulter DxI 9000 Access Immunoassay Analyzer, catalog number C11137; in-vitro diagnostic instrument
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2580-2024·2024-08-21

    VITROS Folate Reagent Pack Recalled for Delayed Test Results

    Ortho-Clinical Diagnostics is recalling VITROS Folate Reagent Pack due to fibrinogen precipitation causing delayed test results. The recall affects 18,467 units distributed worldwide.

    Product
    VITROS Immunodiagnostic VITROS Folate Reagent Pack 1/2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0544-2024·2023-12-20

    FDA Recalls VITROS 4600 Chemistry System for Software-Related Freezes

    Ortho-Clinical Diagnostics is recalling 51 units of the VITROS 4600 Chemistry System due to software defects causing system freezes and disconnections that could delay critical test result reporting.

    Product
    VITROS 4600 Chemistry System Product Code 6802445 and Refurbished Product Code 6900440 Running Software Version 3.8.0
    Category
    Medical Device
    Distribution
    Distributed nationwide