The Recall Desk

Hazard

Material Degradation recalls

120 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
120
Critical
0
Severe
6
Most recent
2026-09-23

Of the 120 material degradation recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 6 (5%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all material degradation recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 120

  • HighFDA (Devices)·Z-0887-2024·2024-02-07

    Knee Replacement Implant Recalled Due to Potential Material Degradation

    Knee replacement components recalled due to potential oxidation in UHMWPE material that could affect durability. Approximately 76 units distributed in the US with additional international distribution.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #5 -Intended for knee replacement Part Number: 73-0510
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0871-2024·2024-02-07

    Knee Replacement Implant Recalled Due to Potential Material Degradation

    Howmedica Osteonics is recalling SCORPIO RECESSED PATELLA knee replacement implants manufactured with UHMWPE material over 5 years old. The aged material may develop elevated oxidation levels that could affect the implant's performance.

    Product
    SCORPIO RECESSED PATELLA- Intended for knee replacement Part Number: 3044-0030
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0896-2024·2024-02-07

    SCORPIO U-DOME PATELLA Knee Implants Affected by Material Oxidation Risk

    Certain SCORPIO U-DOME PATELLA knee replacement devices may experience material degradation due to aged raw material. The manufacturer is recalling affected units because material oxidation could compromise device durability and performance.

    Product
    SCORPIO U-DOME PATELLA -Intended for knee replacement Part Number: 73-3708
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0874-2024·2024-02-07

    Knee replacement tibial insert recalled for potential material oxidation

    Howmedica Osteonics Corp. is recalling Series II tibial bear inserts used in knee replacements. Raw material over 5 years old may have elevated oxidation levels, potentially affecting material properties.

    Product
    SERIES II TIBIAL BEAR INSERT-Intended for knee replacement Part Number: 3052-0524
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0876-2024·2024-02-07

    Knee Implant Inserts Recalled Due to Potential Material Degradation

    Howmedica Osteonics is recalling SCORPIO TS TIB knee implant inserts (Part Number 72-4-0510) manufactured with UHMWPE material over 5 years old. The material may have elevated oxidation levels that could affect implant performance.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-0510
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0870-2024·2024-02-07

    Knee implant component recalled due to potential material oxidation

    Howmedica Osteonics is recalling SCORPIO RECESSED PATELLA knee implant components made from UHMWPE material over 5 years old that may develop elevated oxidation.

    Product
    SCORPIO RECESSED PATELLA- Intended for knee replacement Part Number: 3044-0028
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0922-2024·2024-02-07

    Knee replacement implant recalled for potential material oxidation risk

    Howmedica Osteonics is recalling the DUR PCA MTK REV INS RT knee replacement implant manufactured with UHMWPE material over 5 years old. The material can develop elevated oxidation levels that may degrade its properties.

    Product
    DUR PCA MTK REV INS RT Intended for knee replacement Product Number: 6728-2-711
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0872-2024·2024-02-07

    Knee replacement implant recalled for material oxidation risk

    Howmedica Osteonics is recalling SCORPIO RECESSED PATELLA knee replacement components due to potential oxidation of the UHMWPE material in units manufactured with raw material over 5 years of age.

    Product
    SCORPIO RECESSED PATELLA-Intended for knee repalcment Part Number: 3044-0032
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0921-2024·2024-02-07

    Knee replacement implant recalled due to potential material degradation

    Howmedica Osteonics recalls DUR PCA MTK REV INS RT knee replacement implants due to potential oxidation of UHMWPE material that could compromise material properties. Patients should contact their healthcare provider.

    Product
    DUR PCA MTK REV INS RT Intended for knee replacement Product Number: 6728-2-709
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0885-2024·2024-02-07

    Knee Replacement Insert Recalled Due to Potential Material Oxidation

    Howmedica Osteonics is recalling Scorpio-Flex knee prosthesis inserts due to potential oxidation in UHMWPE raw material over 5 years old, which could impact material properties.

    Product
    Scorpio-Flex Ttl Kn P-S Tib Brg Insrt Asy- -Intended for knee replacement Part Number: 72-16-0910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0908-2024·2024-02-07

    Knee Replacement Inserts Recalled Due to Material Oxidation Risk

    Howmedica Osteonics is recalling knee replacement inserts manufactured with UHMWPE material over 5 years old, which may develop elevated oxidation levels that could affect joint stability.

    Product
    LEFT LARGE-PCA MOD.REV.DUR.REV.INSERT Intended for knee replacement Part Number: 6637-0-231
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0883-2024·2024-02-07

    Knee replacement implant insert recalled due to material oxidation risk

    Howmedica Osteonics is recalling Scorpio-Flex knee implant inserts manufactured with over-5-year-old UHMWPE material, which may develop elevated oxidation levels that could affect material properties.

    Product
    Scorpio-Flex Ttl Kn P-S Tib Brg Insrt Asy- Intended for knee replacement Part Number: 72-15-0324
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0899-2024·2024-02-07

    Knee Replacement Component Recalled Due to Material Oxidation Risk

    Howmedica Osteonics is recalling Scorpio NRG Tibial Brg Insert Assembly knee replacement components due to potential oxidation of raw materials over 5 years of age, which could affect material properties.

    Product
    Scorpio NRG Tibial Brg Insert Assy -Intended for knee replacement Part Number: 82-2-0908
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0890-2024·2024-02-07

    Knee replacement implant recalled due to material oxidation risk

    Howmedica Osteonics is recalling a knee replacement patellar component that may have been manufactured with oxidized raw material. Products using UHMWPE over 5 years old can develop elevated oxidation and degraded material properties.

    Product
    SCORPIO TOTAL KNEE CONCENTRIC DOME PATELLA-SZ #11 -Intended for knee replacement Part Number: 73-2110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0873-2024·2024-02-07

    Series II Tibial Bear Insert Recalled for Potential Material Degradation

    Howmedica Osteonics Corp. is recalling the Series II Tibial Bear Insert for knee replacement because UHMWPE material over 5 years old may develop elevated oxidation that can affect the component's material properties.

    Product
    SERIES II TIBIAL BEAR INSERT-Intended for knee replacement Part Number: 3052-0515
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0889-2024·2024-02-07

    Total Knee Replacement Component Recalled Due to Oxidation Risk

    Howmedica Osteonics Corp. is recalling SCORPIO Total Knee replacement components from specific manufacturing batches due to potential oxidation in raw materials over 5 years old. Oxidation can impact the material's properties.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #9 -Intended for knee replacement Part Number: 73-0910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0906-2024·2024-02-07

    Knee replacement implant insert recalled due to material degradation risk

    Howmedica Osteonics Corp. is recalling a knee replacement implant insert due to potential material oxidation. UHMWPE raw material over 5 years old may develop elevated oxidation levels, affecting implant properties.

    Product
    LEFT SMALL-PCA MOD.REV.DUR.REV.INSERT Intended for knee replacement Part Number: 6637-0-028
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0897-2024·2024-02-07

    Knee replacement component recalled due to potential material oxidation

    Howmedica Osteonics recalls SCORPIO U-DOME PATELLA knee components. Older UHMWPE raw material may have elevated oxidation, potentially affecting material properties.

    Product
    SCORPIO U-DOME PATELLA -Intended for knee replacement Part Number: 73-3710
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0925-2024·2024-02-07

    PS Lipped Tibial Insert Assy Duracon Knee Implant Oxidation Risk

    Howmedica Osteonics is recalling PS Lipped Tibial Insert knee replacement components manufactured with aged UHMWPE material that may develop oxidation, potentially affecting device properties and performance.

    Product
    PS LIPPED TIBIAL INSERT ASSY DURACON Intended for knee replacement Product Number: 6742-1-416
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0886-2024·2024-02-07

    Knee Replacement Component Recalled Due to Raw Material Oxidation Risk

    Howmedica Osteonics Corp. is recalling a SCORPIO TOTAL KNEE prosthesis component because UHMWPE raw material over 5 years old may have elevated oxidation levels affecting material properties and implant performance. Consumers with this implant should contact their physician for guidance.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #11 -Intended for knee replacement Part Number: 73-0110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0918-2024·2024-02-07

    Knee replacement implants recalled for potential material degradation

    Howmedica Osteonics Corp. is recalling DURATION Plastic Patella knee replacement implants due to potential oxidation in UHMWPE raw material over 5 years old, which may affect implant durability.

    Product
    DURATION PLASTIC PATELLA-DURACON Intended for knee replacement Product Number: 6642-2-200
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0891-2024·2024-02-07

    Knee Replacement Implant Component Recalled for Material Degradation Risk

    Howmedica Osteonics Corp. is recalling SCORPIO Total Knee Concentric Dome Patella components due to potential oxidation in raw materials over 5 years old. No illnesses have been reported.

    Product
    SCORPIO TOTAL KNEE CONCENTRIC DOME PATELLA-SZ #7 -Intended for knee replacement Part Number: 73-2710
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0920-2024·2024-02-07

    Knee replacement devices recalled due to potential material degradation

    Howmedica Osteonics Corp. recalls knee replacement devices with UHMWPE components manufactured from raw material over 5 years old due to potential oxidation that may affect material properties.

    Product
    DUR PCA MTK REV INS LFT Intended for knee replacement Product Number: 6728-2-611
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0912-2024·2024-02-07

    Knee Replacement Implant Recalled Due to Potential Material Oxidation Risk

    Howmedica Osteonics Corp. is recalling certain knee replacement implants made with UHMWPE material over 5 years old that may have oxidized, potentially affecting implant performance.

    Product
    RGT.LARGE-PCA MOD.REV.- DUR.REV.INSERT Intended for knee replacement Product Number: 6637-0-928
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0881-2024·2024-02-07

    SCORPIO TS Knee Implant Recall Due to Material Oxidation Risk

    Howmedica is recalling SCORPIO TS knee implants made with raw material over 5 years old due to potential oxidation that could degrade the device's mechanical properties.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-7521
    Category
    Medical Device
    Distribution
    Distributed nationwide