The Recall Desk

Hazard

Loss Of Steering Control recalls

136 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
136
Critical
0
Severe
122
Most recent
2026-10-20

Of the 136 loss of steering control recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 122 (90%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all loss of steering control recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 136

  • SevereNHTSA·26E071000·2026-10-14

    KTM Recalls Steering Dampers for Super Duke Motorcycles

    KTM is recalling certain Müller Präzision steering dampers for 2020-2026 KTM Super Duke R and Evo motorcycles because they can loosen, leading to loss of steering control.

    Product
    STEERING recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V598000·2026-09-17

    Toyota Recalls 2026 Lexus and Grand Highlander Models for Steering Knuckle Defect

    Toyota is recalling 617 specific 2026 Lexus and Toyota models because front steering knuckles may crack, potentially causing a loss of steering control.

    Product
    LEXUS — LEXUS, TOYOTA RX, GRAND HIGHLANDER, GRAND HIGHLANDER HYBRID, RX HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V590000·2026-09-11

    Volkswagen Recalls 2018-2021 Models for Steering Rack Bolt Corrosion

    Volkswagen is recalling 2018-2021 Tiguan, Atlas, and Audi Q3 vehicles because a steering rack bolt may corrode and break, potentially causing loss of steering control.

    Product
    AUDI — AUDI, VOLKSWAGEN Q3, ATLAS, TIGUAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26E060000·2026-08-24

    Rennline Recalls Lower Control Arms Due to Subframe Damage Risk

    Rennline Automotive is recalling 106 lower control arms that may have incorrect dimensions, potentially damaging the subframe and causing loss of steering control.

    Product
    SUSPENSION:FRONT:CONTROL ARM:LOWER ARM recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26E028000·2026-05-11

    Beck/Arnley Replacement Lower Control Arm and Ball Joint Recall

    Federal-Mogul Motorparts is recalling Beck/Arnley replacement lower control arm and ball joint assemblies for 2018-2025 Subaru Forester and Crosstrek vehicles due to loose nuts.

    Product
    SUSPENSION:FRONT:CONTROL ARM:LOWER ARM recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V604000·2025-09-11

    Thomas Built Buses Recalls School Buses Due to Steering Defect

    Daimler Trucks North America is recalling certain 2025-2026 Thomas Built Buses school buses because improperly installed steering fasteners may cause a loss of steering control.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2 JOULEY, SAF-T-LINER C2, SAF-T-LINER EFX, SAF-T-LINER HDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V520000·2025-08-11

    Volvo New VN Trucks Recalled Due to Potential Loss of Steering Control

    Volvo Trucks North America is recalling certain 2025-2026 Volvo New VN trucks because the dynamic steering and oversteer guidance feature may malfunction, increasing the risk of a crash.

    Product
    VOLVO — VOLVO VNL (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V360000·2025-05-30

    Orange EV Recalls Trucks Due to Steering Shaft Bolt Tightening Issue

    Orange EV is recalling 2022-2025 HUSK-e, e-TRIEVER, and T-Series trucks because improperly tightened steering shaft bolts could cause loss of steering control.

    Product
    ORANGE EV — ORANGE EV E-TRIEVER, T-SERIES ELECTRIC TRUCK, HUSK-E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V309000·2025-05-09

    Ford Recalls 2025 F-150 Trucks for Steering Shaft Fastener Defect

    Ford is recalling 2025 F-150 vehicles because lower steering shaft fasteners may detach, causing loss of steering control and increasing crash risk.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E072000·2024-08-26

    USK Internacional Recalls Tie Rod and Drag Link Assemblies

    USK Internacional is recalling certain tie rod and drag link assemblies due to improperly heat-treated ball studs that may break, potentially causing a loss of steering control.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E062000·2024-07-26

    Meritor Recalls Replacement Tie Rods Due to Heat-Treatment Defect

    Meritor is recalling replacement tie rods with specific USK ball studs that may break due to incorrect heat treatment, risking loss of steering control.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V545000·2024-07-23

    Capacity Recalls 2023 TJ Series Vehicles Due to Steering Gear Defect

    Capacity of Texas is recalling 2023 TJ 5000, 6500, and 9000 vehicles because steering gear assemblies may have fewer recirculating balls than required, risking loss of steering control.

    Product
    CAPACITY — CAPACITY TJ 5000, TJ 9000, TJ 6500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E061000·2024-07-19

    Ford Recalls Tie Rod Assemblies Due to Potential Steering Failure

    Ford is recalling specific front axle tie rod assemblies because incorrectly heat-treated ball studs may break, potentially causing loss of steering control.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V539000·2024-07-18

    Hyundai Recalls 2023 Xcient Trucks for Steering Control Risk

    Hyundai is recalling 2023 Xcient vehicles because the pitman arm may not be secured properly, which can result in a loss of steering control and increase the risk of a crash.

    Product
    HYUNDAI — HYUNDAI XCIENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V524000·2024-07-09

    Volvo Bus 9700 Recall for Steering Gear Link Rod Nut Tightening

    Volvo Bus is recalling 2024 9700 vehicles because improperly tightened nuts on the steering gear link rod may loosen, potentially causing loss of steering control.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V467000·2024-06-21

    Isuzu Recalls 2025 FTR Trucks Due to Tie Rod Assembly Defect

    Isuzu is recalling 2025 FTR vehicles because incorrectly heat-treated ball studs in the tie rod assemblies may break, potentially causing loss of steering control.

    Product
    ISUZU — ISUZU FTR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V463000·2024-06-20

    Navistar Recalls 2025 IC Bus CE School Buses for Tie Rod Defect

    Navistar is recalling 2025 IC Bus CE school buses because incorrectly heat-treated tie rod assemblies may break, potentially causing loss of steering control.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V433000·2024-06-12

    2025 Kenworth and Peterbilt Trucks Steering Linkage Defect

    PACCAR is recalling 2025 Kenworth and Peterbilt trucks due to improperly heat-treated ball studs in steering assemblies that may break, causing loss of steering control.

    Product
    KENWORTH — KENWORTH, PETERBILT T880, T480, T380, T280
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V398000·2024-06-04

    Mack Trucks Recalls 2025 Models Due to Steering Control Loss Risk

    Mack Trucks is recalling 2025 AN, GR, and TE trucks because a defective drag link may cause sudden loss of steering control, increasing crash risk.

    Product
    MACK — MACK ANTHEM (AN), TE, GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide