The Recall Desk

Hazard

Implant recalls

74 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
74
Critical
3
Severe
0
Most recent
2026-06-24

Of the 74 implant recalls we have scored against our rubric, 3 (4%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all implant recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 74

  • HighFDA (Devices)·Z-0974-2026·2025-12-31

    Femoral nails, 300 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 11 Affixus Antegrade Femoral Nails, model 815609300, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609300 Software Version: N/A Product Description: Affixus 9 mm, Length 300 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0972-2026·2025-12-31

    Femoral nails, 420 mm right trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 22 Affixus Antegrade Femoral Nails, model 815509420, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815509420 Software Version: N/A Product Description: Affixus 9 mm, Length 420 mm, Right, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0971-2026·2025-12-31

    Femoral nails, 400 mm right trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 23 Affixus Antegrade Femoral Nails, model 815509400, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815509400 Software Version: N/A Product Description: Affixus 9 mm, Length 400 mm, Right, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0996-2026·2025-12-31

    Femoral nails, 360 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 24 Affixus Antegrade Femoral Nails, model 815609360, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Restore Clinician Programmer Application (CP App), Model A71100 used with the following programmers: CT900A PROG CT900A CLINICIAN TABLET US CT900B PROG CT900B CLINICIAN TABLET EU -UK CT900C PROG CT900C CLINICIAN TABLET UK CT900D PROG CT900D CLINICIAN TABLET GLOBAL CT900E P
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0973-2026·2025-12-31

    Femoral nails, 440 mm right trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 22 Affixus Antegrade Femoral Nails, model 815509440, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815509440 Software Version: N/A Product Description: Affixus 9 mm, Length 440 mm, Right, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0979-2026·2025-12-31

    Femoral nails, 400 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 24 Affixus Antegrade Femoral Nails, model 815609400, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609400 Software Version: N/A Product Description: Affixus 9 mm, Length 400 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0976-2026·2025-12-31

    Femoral nails, 340 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 24 Affixus Antegrade Femoral Nails, model 815609340, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609340 Software Version: N/A Product Description: Affixus 9 mm, Length 340 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0981-2026·2025-12-31

    Femoral nails, 440 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 24 Affixus Antegrade Femoral Nails, model 815609440, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609440 Software Version: N/A Product Description: Affixus 9 mm, Length 440 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0980-2026·2025-12-31

    Femoral nails, 420 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 23 Affixus Antegrade Femoral Nails, model 815609420, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609420 Software Version: N/A Product Description: Affixus 9 mm, Length 420 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·H-0255-2026·2025-12-17

    Knee fusion nail components recalled over a locking screw inserted backwards

    Waldemar Link is recalling 18 Endo Model Knee Fusion Nail SK coupling components delivered with a preassembled locking screw inserted from the wrong side into the male taper.

    Product
    Deep-brand Premium Select Karela Ring Cut KEEP FROZEN Net Wt. 12 oz. (340 g)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0871-2026·2025-12-10

    Fibula nails recalled over out of specification thread depths on the implant

    Paragon 28 is recalling 20 Phantom Fibula Nails because out of specification thread depths may prevent the implant from mating with its mounting bolt, potentially requiring surgery to be aborted.

    Product
    Phantom Fibula Nail, 2.8mm x 130mm, Right, Ti, Fibula Nail, REF: P36-128-130R-S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0531-2026·2025-12-03

    Pericardial patches recalled because a lot may not meet tensile strength

    Glycar SA is recalling 30 SJM Pericardial Patches with EnCap Technology because the impacted lot may not meet the required tensile strength specification. The FDA classified it Class I.

    Product
    SJM Pericardial Patch, with EnCap Technology 9x14cm, Model Number REF C0914; PATCH, PLEDGET AND INTRACARDIAC, PETP, PTFE, POLYPROPYLENE
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0532-2026·2025-12-03

    Smaller pericardial patches recalled over a tensile strength specification failure

    Glycar SA is recalling 18 SJM Pericardial Patches, 5 x 10 cm, because the impacted lot may not meet the required tensile strength specification. The FDA classified it Class I.

    Product
    SJM Pericardial Patch, with EnCap Technology 5x10 cm, Model Number REF C0510; PATCH, PLEDGET AND INTRACARDIAC, PETP, PTFE, POLYPROPYLENE
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0540-2026·2025-11-26

    Bone void implants recalled over an incorrect product name on packaging

    Berkeley Advanced Biomaterials is recalling 62 Tribio Implants 7.5mm x 40mm because the outer packaging carries an incorrect product name.

    Product
    Tribio Implant 7.5mm x 40mm REF M80 SB008 UDI code: (01) 00816125023653(10) EBL10B13C(17) 270630 Tribio" Implant is indicated for use in bony voids or gaps of the skeletal system (i.e. extremities, pelvis and posterolateral spine). These osseous defects are surgically created
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0459-2026·2025-11-19

    Deep brain stimulators recalled over loss of programmer communication

    Abbott Medical is recalling 722 Liberta RC deep brain stimulation implantable pulse generators because the devices may lose communication with the clinician programmer or patient controller.

    Product
    Liberta RC DBS IPG (Implantable Pulse Generator), Model Number 62400
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0478-2026·2025-11-19

    Spinal fixation screws recalled for not meeting performance standards

    Orthofix is recalling 624 Virata preassembled polyaxial screws used in the Virata Spinal Fixation System because the screws do not meet performance standards.

    Product
    Virata Preassembled Polyaxial Screw, utilized in the Virata Spinal Fixation System. The following sizes are affected: 1. POLYAXIAL SCREW, CC, 5.5mm X 30mm; Item Number: TL1-10755030. 2. POLYAXIAL SCREW, CC, 5.5mm X 35mm; Item Number: TL1-10755035. 3. POLYAXIAL SCREW, CC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0458-2026·2025-11-19

    Spinal cord stimulators recalled over loss of programmer communication

    Abbott Medical is recalling 20,715 Eterna spinal cord stimulation implantable pulse generators because the devices may lose communication with the clinician programmer or patient controller.

    Product
    Eterna SCS IPG (Implantable Pulse Generator), Model Number 32400
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0418-2026·2025-11-12

    Hip bearings recalled because size F packages contain size G implants

    Zimmer is recalling 72 Dual Mobility Vivacit-E bearings labelled Size F 44 mm because the implant inside the package is a Size G 46 mm, and the reverse also occurred.

    Product
    Zimmer Biomet Dual Mobility Vivacit-E Highly Crosslinked Polyethylene, 28 mm I.D., 44 mm O.D., Size F, Bearing, Model/Catalog Number: 110031012; semi constrained hip prosthesis
    Category
    Medical Device
    Distribution
    20 states
  • HighFDA (Devices)·Z-0432-2026·2025-11-12

    Hip bipolar heads recalled over packaging that may compromise sterility

    Total Joint Orthopedics is recalling 103 Klassic BiPolar Heads over a potential packaging issue that could compromise the sterile barrier and present a risk of infection if implanted.

    Product
    Brand Name: Klassic BiPolar Head Model/Catalog Number: 3205.41.022 Klassic BiPolar Head, 41 mm OD, 22 mm Head; 3205.42.022 Klassic BiPolar Head, 42 mm OD, 22 mm Head; 3205.43.022 Klassic BiPolar Head, 43 mm OD, 22 mm Head; 3205.44.028 Klassic BiPolar Head, 44 mm OD, 28 mm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0419-2026·2025-11-12

    Size G hip bearings recalled over commingled implant sizes in packaging

    Zimmer is recalling 63 Dual Mobility Vivacit-E bearings labelled Size G 46 mm because the package contents and label may be commingled with the Size F 44 mm bearing.

    Product
    Zimmer Biomet Dual Mobility Vivacit-E Highly Crosslinked Polyethylene, 28 mm I.D., 46 mm O.D., Size G, Bearing, Model/Catalog Number: 110031013; semi constrained hip prosthesis
    Category
    Medical Device
    Distribution
    20 states
  • HighFDA (Devices)·Z-0417-2026·2025-11-12

    Dental implant screws recalled because the wrong screw was packaged

    Prismatik Dentalcraft is recalling 208 Inclusive Titanium Screws because an incorrect titanium screw was packaged with the dental implant.

    Product
    Brand Name: Inclusive Product Name: Inclusive Titanium Screw compatible with: Biomet 3i" Certain 3.4/4.1/5.0/6.0 mm Model/Catalog Number: 70-1047-COM0117
    Category
    Medical Device
    Distribution
    18 states
  • HighFDA (Devices)·Z-0316-2026·2025-11-05

    Soft tissue markers recalled over potential contamination with cotton fibers

    Endomagnetics is recalling 1,760 Magseed Pro 7 cm soft tissue markers because of the potential for contamination with cotton fibers.

    Product
    Magseed Pro 7 cm soft tissue marker. Model Number: MS2-17-1-07. Product Description: The Endomag Magseed Pro Magnetic Marker System is a sterile, single use device composed of a marker preloaded in a 17ga Needle Delivery System. The Endomag Magseed Pro Marker is indicated for
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0317-2026·2025-11-05

    Magseed Pro 12 cm markers recalled over potential cotton fiber contamination

    Endomagnetics is recalling 540 Magseed Pro 12 cm soft tissue markers because of the potential for contamination with cotton fibers.

    Product
    Magseed Pro 12 cm soft tissue marker. Model Number: MS2-17-1-12. Product Description: The Endomag Magseed Pro Magnetic Marker System is a sterile, single use device composed of a marker preloaded in a 17ga Needle Delivery System. The Endomag Magseed Pro Marker is indicated for
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0212-2026·2025-10-29

    AC joint fixation implants recalled over potentially missing slotted button assembly

    Biomet is recalling 98 ZipTight Acute AC Joint Implants from one lot because of the potential for a missing slotted button assembly.

    Product
    BIOMET ZipTight, Acute AC Joint Implant, Single Ziploop , Model/Catalog Number: 904834; Fixation System for AC Joint Repair
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0227-2026·2025-10-29

    Bipolar hip heads recalled downstream after femoral components failed transit testing

    Theken Companies is recalling 409 iNSitu Bipolar Hip System head assemblies in a downstream recall after BioPro femoral components failed transit testing, risking sterile barrier issues.

    Product
    iNSitu Bipolar Hip System, Bipolar head implant Part ID Description 10-22-0038 Bipolar Head Assembly, Size 38mm 10-22-0040 Bipolar Head Assembly, Size 40mm 10-22-0042 Bipolar Head Assembly, Size 42mm 10-22-0044 Bipolar Head Assembly, Size 44mm 10-22-0046 Bipolar Head Asse
    Category
    Medical Device
    Distribution
    Distributed nationwide