The Recall Desk

Hazard

Image Rotation recalls

17 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
17
Critical
0
Severe
0
Most recent
2024-12-11

Of the 17 image rotation recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all image rotation recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–17 of 17

  • HighFDA (Devices)·Z-0612-2025·2024-12-11

    GE Healthcare CT systems produce progressively rotated images in scan modes

    Certain GE Healthcare CT systems can produce progressively rotated images during helical and cardiac scans. Images may rotate up to 56 degrees, potentially affecting diagnosis if the rotation is not detected.

    Product
    GE Healthcare Revolution Maxima Select, Model Number, 6670000-55; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0603-2025·2024-12-11

    GE Healthcare Revolution ACE CT Systems Image Rotation Issue

    GE Healthcare's Revolution ACE CT systems can produce progressively rotated images during certain scan modes. Maximum rotation reaches 56 degrees, potentially affecting diagnostic interpretation.

    Product
    GE Healthcare Revolution ACE, Model number 6670000-3; X-ray/computed tomography systems
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0607-2025·2024-12-11

    GE Healthcare CT Imaging System May Produce Rotated Medical Images

    GE Healthcare CT systems may produce progressively rotated images during helical, cine, and cardiac scans. The issue affects 4 units worldwide and can cause rotations up to 56 degrees.

    Product
    GE Healthcare Revolution Eagle, Model Number 5849504-3, X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0611-2025·2024-12-11

    GE Healthcare CT System May Produce Rotated Diagnostic Images

    GE Healthcare's Revolution Maxima M and related CT systems may produce progressively rotated images during scans, potentially compromising diagnostic accuracy. Rotation increases with each image, reaching up to 56 degrees.

    Product
    GE Healthcare Revolution Maxima M, Model Number, 6670000-2; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0608-2025·2024-12-11

    GE Healthcare CT Systems Recalled Due to Progressive Image Rotation

    GE Healthcare CT systems may display progressively rotated images, particularly in helical, cine, and cardiac scans. Rotations up to 56 degrees may affect image interpretation and could necessitate additional patient scanning.

    Product
    GE Healthcare Revolution EVO, Model Number 5454001-260; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0601-2025·2024-12-11

    GE Healthcare Optima 520 CT systems recalled for image rotation

    GE Healthcare recalled 11 Optima 520 CT systems that produce progressively rotated scan images in helical, cine, and cardiac modes, potentially affecting diagnostic accuracy.

    Product
    GE Healthcare Optima 520, Catalog number 5439126; X-ray/computed tomography systems
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0610-2025·2024-12-11

    GE Healthcare Revolution Maxima CT Systems Recalled for Progressive Image Rotation

    GE Healthcare recalled Revolution Maxima and related CT imaging systems that can produce progressively rotated images during helical, cine, and cardiac scans. Approximately 72 units worldwide are affected; no patient injuries reported.

    Product
    GE Healthcare Revolution Maxima, Model Numbers: 1) 6665000-2, 2) 6670000-2, 3) 6670000-200, 4) 6670000-6; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0615-2025·2024-12-11

    GE Healthcare CT Operator Console Update: Images May Rotate Progressively

    GE Healthcare operator console upgrades for certain CT systems can cause progressive image rotation during scans. Images may rotate up to 56 degrees per exam, potentially affecting diagnostic accuracy.

    Product
    GE Healthcare Operator Console Upgrade Types, FRU Spare Parts Number B80522DA: China Only: Revolution Discovery CT
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0600-2025·2024-12-11

    GE Healthcare CT Systems May Display Rotated Images in Diagnostic Scans

    Certain GE Healthcare CT systems may produce progressively rotated images during diagnostic scans. If undetected and a rescan is needed, the same rotation recurs.

    Product
    GE Healthcare Discovery RT, Model Number 2374681-17, X-ray/computed tomography systems labeled as:
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0613-2025·2024-12-11

    GE Healthcare CT Operator Console Images May Rotate During Scans

    GE Healthcare CT systems may produce progressively rotated images during helical, cine, and cardiac scans. Images can rotate up to 56 degrees, potentially requiring patient rescans.

    Product
    GE Healthcare Operator Console Upgrade Types, FRU Spare Parts Number B79632DA: EU: RT Refresh Package, Non-EU: Discovery RT, Optima CT580, or Discovery CT590 RT; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0605-2025·2024-12-11

    GE Healthcare Revolution Ascend CT System Recalled for Image Rotation

    GE Healthcare Revolution Ascend CT systems can produce progressively rotated images during helical, cine, and cardiac scans. Images after the first may be rotated up to 56 degrees, potentially affecting diagnostic accuracy.

    Product
    GE Healthcare Revolution Ascend, Model number 6969000-100; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0604-2025·2024-12-11

    CT imaging systems may display progressively rotated images in certain scan modes

    Certain GE Healthcare CT systems may display progressively rotated images, particularly during helical, cine, or cardiac scans. The rotation increases with each image, potentially reaching 56 degrees maximum.

    Product
    GE Healthcare Revolution Advance, Model number 5849504; X-ray/computed tomography systems
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0606-2025·2024-12-11

    CT imaging system issue causes progressive image rotation during scans

    GE Healthcare CT systems have a technical issue causing progressive image rotation during helical and cardiac scans. No injuries reported, but unnoticed rotation could affect diagnosis or require rescans.

    Product
    GE Healthcare Revolution Ascend Elite, Model Number 6967000-100; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0602-2025·2024-12-11

    CT Image Rotation Issue in GE Healthcare Optima 680 Systems

    GE Healthcare Optima 680 Expert CT systems may produce progressively rotated images during helical and cardiac scans. Affected images may require rescanning for accurate clinical interpretation.

    Product
    GE Healthcare Optima 680 Expert, Model number 6670000; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0609-2025·2024-12-11

    GE Healthcare Revolution Frontier CT systems may produce rotated images during scans

    GE Healthcare Revolution Frontier CT systems can produce progressively rotated images during helical, cine, and cardiac scans. The rotation can reach up to 56 degrees and may require repeat scans.

    Product
    GE Healthcare Revolution Frontier, Model Numbers: 1) 5232085-213, 2) 5873009; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0614-2025·2024-12-11

    GE Healthcare CT Imaging Systems Recalled for Progressive Image Rotation

    GE Healthcare is recalling operator console upgrades for certain CT systems due to a software defect causing progressive image rotation during scans. Rotations can reach up to 56 degrees and may require patient rescanning.

    Product
    GE Healthcare Operator Console Upgrade Types, FRU Spare Parts Number B80212DA: EU: Operator Console (for BrightSpeed, Elite/BrightSpeed Elite Select), Non-EU: BrightSpeed Elite, BrightSpeed Elite Select; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0616-2025·2024-12-11

    GE Healthcare CT Scanner Console Images May Rotate After First Scan

    Certain GE Healthcare CT scanner systems may produce progressively rotated images after the first scan, with rotation up to 56 degrees. While anatomical data remains intact, misaligned images could necessitate patient rescans.

    Product
    GE Healthcare Operator Console Upgrade Types, FRU Spare Parts Number B80662DA: China Only: Discovery CT750HD
    Category
    Medical Device
    Distribution
    0 states