What the numbers show

Total
32
Critical
0
Severe
0
Most recent
2026-01-28

Of the 32 image artifact recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all image artifact recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–32 of 32

  • HighFDA (Devices)·Z-2256-2015·2015-08-05

    Philips Brilliance iCT SP CT Systems Recalled for Software Defects

    Philips Medical Systems is recalling two Brilliance iCT SP CT systems due to software issues affecting image quality, dose control, and heart rate measurement.

    Product
    Computed Tomography X-ray Systems Brilliance iCT SP. Intended to produce cross-sectional images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2259-2015·2015-08-05

    Philips Ingenuity CT Scanners Recalled for Software and Hardware Defects

    Philips is recalling 159 Ingenuity CT scanners due to software errors affecting dose control, image artifacts, and heart rate measurement.

    Product
    Computed Tomography X-ray Systems Ingenuity CT scanners. Intended to produce cross-sectional images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2254-2015·2015-08-05

    Philips Brilliance CT 64-Channel Systems Recalled for Software Defects

    Philips is recalling four Brilliance CT 64-channel systems due to software errors affecting image quality, dose control, and heart rate measurements.

    Product
    Computed Tomography X-ray Systems Brilliance CT 64-channel with Essence technology. Intended to produce cross-sectional images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1693-2015·2015-06-24

    Neusoft NeuViz 64 CT Scanner Recalled for Teflon Compensator Failure

    Neusoft Medical System Co is recalling NeuViz 64 CT scanners because the Teflon A-plane compensator degrades under X-ray exposure, causing premature failure and image artifacts.

    Product
    Neusoft NeuViz 64 Multi-slice CT Scanner System
    Category
    Medical Device
    Distribution
    5 states
  • ModerateFDA (Devices)·Z-0832-2014·2014-02-05

    Philips Brilliance iCT Computed Tomography Systems Recalled for Image Artifacts

    Philips is recalling seven Brilliance iCT and iCT SP CT scanners because patient images exhibited ring artifacts.

    Product
    Brilliance iCT & Brilliance iCT SP Computed Tomography X-Ray Systems, Philips Healthcare, Cleveland, OH The Brilliance iCT and iCT SP are whole body Computed Tomography X-Ray Systems intended to produce cross-sectional images of the body by computer reconstruction of x-ray tr
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0090-2014·2013-11-06

    Carestream DRX Revolution Mobile X-Ray System Recalled for Image Artifacts

    Carestream Health is recalling 23 DRX Revolution Mobile X-Ray Systems because a software update without detector calibration can cause image artifacts.

    Product
    DRX Revolution Mobile X-Ray System, Model DRXR-1, Verona Street Rochester, NY 14608 Catalog Numbers 1019397, 1023415, 1023423 --- Made in USA by Carestream Health, Inc. 150 The device is designed to perform radiographic x-ray examinations on all pediatric and adult patient
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1646-2013·2013-07-10

    Philips CT Scanners Recalled for Image Artifacts Impairing Diagnostic Quality

    Philips is recalling Brilliance CT 64 and Ingenuity Core scanners due to software issues causing image artifacts that may impair diagnostic quality.

    Product
    Computed Tomography X-ray systems Product Usage: The Brilliance CT 64, Ingenuity Core, and Ingenuity Core128 scanners are whole body Computed Tomography X-ray systems that are intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmis
    Category
    Medical Device
    Distribution