The Recall Desk

Hazard

Embolism Risk recalls

12 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
12
Critical
8
Severe
0
Most recent
2026-08-05

Of the 12 embolism risk recalls we have scored against our rubric, 8 (67%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all embolism risk recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–12 of 12

  • CriticalFDA (Devices)·Z-2792-2026·2026-08-05

    Cardiovascular Procedure Kits Recalled Due to Particulate in Fluid Path

    Medical Action Industries is recalling cardiovascular procedure kits containing manifolds that may have particulate in the fluid path, which could enter blood circulation and lodge in blood vessels. FDA Class I.

    Product
    Pack Angiography NCMC 3/Cs BANNER, REF: NCAG62I, containing Medline Namic Angiographic Star Off Handle Manifolds
    Category
    Medical Device
    Distribution
    2 states
  • CriticalFDA (Devices)·Z-1322-2026·2026-02-18

    Reprocessed electrophysiology catheters recalled over residual material particles

    Medline is recalling 48 reprocessed St. Jude Supreme and Response diagnostic electrophysiology catheters because these lots may contain small particles of residual material.

    Product
    Reprocessed St. Jude Supreme and Response Diagnostic Electrophysiology Catheters: St. Jude Medical Supreme Diagnostic Electrophysiology Catheter 4 Elec. 2-5-2mm 401211RH 401222RH 401223RH 401226RH 401227RH 401260RH 401261RH 401306RH 401309RH 401312RH 401430RH…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1320-2026·2026-02-18

    Reprocessed Inquiry catheters recalled over residual material particles inside

    Medline is recalling 311 units because these lots of reprocessed catheters may contain small particles of residual material.

    Product
    Reprocessed Abbott Inquiry Steerable Diagnostic Catheters: Abbott Inquiry Steerable Diagnostic Catheter 10 Elec. 2-5-2mm 81105RH 81172RH; Abbott Inquiry Steerable Diagnostic Catheter 20 Elec. 2-10-2mm 81202RH; Abbott Inquiry Steerable Diagnostic Catheter 4 Elec.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1321-2026·2026-02-18

    Reprocessed Livewire catheters recalled over residual material particles

    Medline is recalling 41 reprocessed Livewire steerable diagnostic electrophysiology catheters because these lots may contain small particles of residual material.

    Product
    Reprocessed Livewire Steerable Diagnostic Electrophysiology Catheters: Livewire Steerable Electrophysiology Catheter,10 Elec. 2-5-2mm 401582RH 401940RH; Livewire Steerable Electrophysiology Catheter,20 Elec. 2-10-2mm 401904RH; Livewire Steerable Electrophysiology…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1325-2026·2026-02-18

    Reprocessed AcuNav catheters recalled over residual material particles inside

    Medline is recalling 511 reprocessed Siemens ACUSON AcuNav diagnostic ultrasound catheters because these lots may contain small particles of residual material.

    Product
    Reprocessed Siemens ACUSON AcuNav Diagnostic Ultrasound Catheters: ACUSON AcuNav Ultrasound Catheter, Use on GE Systems 10135910RH; 10043342RH ACUSON AcuNav Ultrasound Catheter, Use on Siemens Systems 10135936RH, 08255790RH
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1324-2026·2026-02-18

    Reprocessed ultrasound catheters recalled over residual material particles inside

    Medline is recalling 94 units because these lots of reprocessed catheters may contain small particles of residual material.

    Product
    Reprocessed Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheters: Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter Use on GE Systems 10439072RH; Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter Use on Siemens Systems 10438577RH…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1323-2026·2026-02-18

    Reprocessed ViewFlex ICE catheters recalled over residual material particles

    Medline is recalling 650 units because these lots of reprocessed catheters may contain small particles of residual material.

    Product
    Medline ReNewal Reprocessed ViewFlex Xtra ICE Catheters: ViewFlex Xtra ICE Catheter 9F x 90cm D087031RH 20197344019554¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1319-2026·2026-02-18

    Reprocessed Webster CS catheters recalled over residual material particles

    Medline is recalling 228 units because these lots of reprocessed catheters may contain small particles of residual material.

    Product
    Medline ReNewal Reprocessed Webster CS Catheters: Webster CS Catheter 10 Electrodes 2-8-2mm Spacing w/AutoID w/ EZ Steer BD710DF282CRH; Webster CS Catheter 10 Electrodes, 2-8-2mm Spacing w/ EZ Steer BD710DF282RRH BD710FJ282RRH; Webster CS Catheter 10 Electrodes, 2-8-2mm…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0574-2026·2025-11-26

    Reprocessed imaging catheters recalled after exceeding validated reprocessing cycles

    Sterilmed is recalling four reprocessed ACUSON AcuNav diagnostic ultrasound catheters because they were reprocessed beyond validated cycles.

    Product
    Brand Name: Sterilmed Reprocessed Imaging Catheter Product Name: ACUSON, CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR FOR USE WITH SIEMENS SYSTEM Model/Catalog Number: ACU10135936 Software Version: N/A Product Description: ACUSON, CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR FOR…
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-0573-2026·2025-11-26

    Non Siemens imaging catheters recalled after exceeding validated reprocessing cycles

    Sterilmed is recalling six reprocessed ACUSON AcuNav diagnostic ultrasound catheters, the variant not for use with Siemens systems, because they were reprocessed beyond validated cycles.

    Product
    Brand Name: ACUSON, CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR NOT FOR USE WITH SIEMENS SYSTEM Product Name: CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR NOT FOR USE WITH SIEMENS SYSTEM Model/Catalog Number: ACU10135910 Software Version: N/A Product Description: ACUSON, CATHETER…
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-1771-2024·2024-05-15

    DURAMAX vascular catheter recalled for possible metal shaving hazard

    The DURAMAX STACKED TIP vascular catheter may contain loosely affixed metal shavings that could embolize and require surgical removal. Lot 5807208 affected, 15 units.

    Product
    DURAMAX STACKED TIP 28 CM STRAIGHT VASC-PAK, 1-UP PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103028191
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1774-2024·2024-05-15

    Vascular access device recalls due to metal shaving contamination risk

    Angiodynamics is recalling the BioFlo DuraMax 15.5F Single Valve Sheath VascPak Kit due to possible loose metal shavings. Metal shavings could enter the bloodstream and require surgical removal.

    Product
    BioFlo DuraMax 15.5F 24cm Single Valve Sheath VascPak Kit- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H965103038181
    Category
    Medical Device
    Distribution
    1 state