The Recall Desk

Hazard

Electrolyte Leak recalls

3 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
3
Critical
0
Severe
3
Most recent
2023-09-27

Of the 3 electrolyte leak recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 3 (100%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all electrolyte leak recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–3 of 3

  • SevereFDA (Devices)·Z-2529-2023·2023-09-27

    Ventilator Control Board Spare Parts Recalled Due to Electrical Short-Circuit Risk

    Hamilton Medical is recalling 6 control board spare parts for ventilators due to degrading capacitors that may leak electrolyte and cause electrical short circuits, potentially interrupting ventilation.

    Product
    Hamilton C1/T1/MR1, REF: MSP161502/12, Control Board Spare part for ventilator
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2530-2023·2023-09-27

    Ventilator Spare Parts Recalled for Degrading Capacitor Risk

    Hamilton Medical is recalling ventilator spare parts (ESM Shielding Set) due to potentially degrading capacitors on the control board. These capacitors may leak electrolyte and cause a short circuit, interrupting ventilation.

    Product
    Hamilton-T1, REF: MSP161339/02, ESM Shielding Set, Spare Part for ventilator
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2527-2023·2023-09-27

    Hamilton-T1 Ventilator Recall: Degrading Capacitors May Interrupt Ventilation

    Hamilton Medical recalls 1,216 Hamilton-T1 ventilators due to degrading capacitors on the control board that may leak electrolyte and interrupt ventilation. The recall affects units distributed nationwide in the US and Puerto Rico.

    Product
    Hamilton-T1, REF: 161009, Intensive Care and Transport Ventilator
    Category
    Medical Device
    Distribution
    Distributed nationwide