The Recall Desk

Hazard

Diagnostic Accuracy recalls

18 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
18
Critical
0
Severe
0
Most recent
2026-07-29

Of the 18 diagnostic accuracy recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all diagnostic accuracy recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–18 of 18

  • HighFDA (Devices)·Z-2777-2026·2026-07-29

    Emano Flow Uroflowmetry App Recalled Over Biased Flow Estimates

    Emano Metrics is recalling 685 units of the Emano Flow smartphone-based acoustic uroflowmetry app (v2.0.0) because recordings captured at 48,000 Hz were processed by models trained on 44,100 Hz audio, producing systematically biased urinary flow rate and voided volume estimates.

    Product
    Emano Flow with software version v2.0.0 GS1 GTIN code: 199874903484 Emano Flow is a smartphone-based acoustic uroflowmetry system. Software-only device that measures urinary flow rate and voided volume from the acoustic signal of urination. No physical components. Distributed
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1806-2026·2026-04-22

    Yeastone Broth recalled because it may report incorrect susceptibility results

    Yeastone Broth is being recalled because the product may report incorrect antifungal susceptibility results during quality control, which could delay treatment or force a change of agent.

    Product
    Yeastone Broth, 11ML, 10/BOX YY3462
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1794-2026·2026-04-15

    MicroScan multidrug resistance test panels recalled over incorrect processing

    MicroScan Neg Multidrug Resistant MIC 1 panels are being recalled because of a manufacturing issue involving incorrect processing of the in vitro multidrug resistant test. Three boxes are affected.

    Product
    MicroScan Neg Multidrug Resistant MIC 1 REF C32368 UDI-DI code: 15099590720568 Intended Use- For use with MicroScan Dried Gram Negative MIC/Combo Panels and Dried Gram Negative Breakpoint Combo Panels. MicroScan panels are designed for use in determining antimicrobial agen
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1795-2026·2026-04-15

    Preeclampsia growth factor assay recalled over out-of-range quality control values

    B.R.A.H.M.S PlGF Plus KRYPTOR in vitro diagnostic tests are being recalled after customers observed out-of-range values at the lowest quality control level, which can contribute to falsely elevated results.

    Product
    B¿R¿A¿H¿M¿S KRYPTOR compact REACT, REF: 89986, used with B¿R¿A¿H¿M¿S PlGF Plus KRYPTOR, REF: 859075N, and run on the B¿R¿A¿H¿M¿S KRYPTOR compact PLUS analyzers. in vitro diagnostic test for Placental Growth Factor
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-1789-2025·2025-05-28

    SmartPath to dStream 3.0T Medical Device Recall for Software Error

    Philips is recalling the SmartPath to dStream 3.0T medical device due to potential alignment errors in the cross reference line functionality when reviewing images generated with the MobiView application. This could affect image interpretation accuracy.

    Product
    Product Name: SmartPath to dStream for 3.0T; Model Number: 782145
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0601-2025·2024-12-11

    GE Healthcare Optima 520 CT systems recalled for image rotation

    GE Healthcare recalled 11 Optima 520 CT systems that produce progressively rotated scan images in helical, cine, and cardiac modes, potentially affecting diagnostic accuracy.

    Product
    GE Healthcare Optima 520, Catalog number 5439126; X-ray/computed tomography systems
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0609-2025·2024-12-11

    GE Healthcare Revolution Frontier CT systems may produce rotated images during scans

    GE Healthcare Revolution Frontier CT systems can produce progressively rotated images during helical, cine, and cardiac scans. The rotation can reach up to 56 degrees and may require repeat scans.

    Product
    GE Healthcare Revolution Frontier, Model Numbers: 1) 5232085-213, 2) 5873009; X-ray/computed tomography system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2734-2024·2024-09-04

    Electrocardiograph Recall: CARDIOVIT AT-180 May Produce Signal Artifacts

    Schiller is recalling CARDIOVIT AT-180 electrocardiographs due to potential high-frequency signal artifacts during ECG acquisition that may affect diagnostic accuracy. 1,084 units are affected worldwide.

    Product
    CARDIOVIT AT-180. Model Number: 0A.110000; Catalog number: 3.920570
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1003-2024·2024-02-14

    Siemens Atellica CH Immunoglobulin M Reagent Quality Control Bias

    Siemens is recalling 7,075 units of its Total Immunoglobulin M diagnostic reagent due to potential negative bias in quality control and patient sample results. This could affect the accuracy of test results.

    Product
    Total immunoglobulin M (IgM total) IVD, kit, nephelometry/turbidimetry
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0314-2024·2023-11-22

    Blood culture kit recalled due to expired internal components

    Medline's blood culture kit is being recalled because components inside the kit have expired before the kit's stated expiration date. This could affect the kit's ability to function properly.

    Product
    BLOOD CULTURE KIT, REF DYNDH1647B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0588-2022·2022-02-16

    Diagnostic Quality Control Microorganism Set Fails Gentamicin Susceptibility Specifications

    Microbiologics Inc is recalling 139 units of KWIK-STIK AST-GP QC microorganism sets due to incorrect susceptibility test results. The products failed gentamicin synergy specifications and could affect the accuracy of laboratory diagnostic testing.

    Product
    QC Sets and Panels, KWIK-STIK AST-GP (6 Strains) QC Set. KWIK-STIK kit that contains Catalog Number 0959P. In Vitro Diagnostic Control microorganisms
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0452-2022·2022-01-12

    Biomeme SARS-CoV-2 Test Instructions Recall: Incorrect Buffer Shelf-Life

    Biomeme, Inc. is recalling instructions for the SARS-CoV-2 Real Time RT-PCR Test because shelf-life guidance for resuspended RPC Buffer is incorrect. Instructions specify one week stability, but the buffer is only stable for two days at room temperature.

    Product
    Biomeme SARS-CoV-2- Real Time RT-PCR Test, Instructions for Use, Part number 100002824 Subcomponent of: SARS-CoV-2 Go-Strips, 3000555; SARS-CoV-2 Go-Plates, 3000562; SARS-Cov-2 Bulk Vials, 3000564
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-0139-2022·2021-10-27

    GE SIGNA Artist MRI System May Produce Incomplete Image Scans

    GE Healthcare recalls 18 SIGNA Artist MRI systems with a software defect that may cause missing image slices, creating gaps in 3D scans that could affect diagnostic accuracy.

    Product
    SIGNA Artist nuclear magnetic resonance imaging system
    Category
    Medical Device
    Distribution
    19 states
  • ModerateFDA (Devices)·Z-1749-2017·2017-04-12

    Siemens ADVIA Centaur BR Assay Recalled for Potential Syphilis Assay Interference

    Siemens is recalling ADVIA Centaur BR assays due to potential interference from the Syphilis assay, which may affect test accuracy.

    Product
    Siemens ADVIA Centaur BR assay Cat No. 09010686, SMN 10340081 (5-pack/250 tests - REF) BR Assay for CA 27.29 The ADVIA Centaur¿ BR assay is an in vitro diagnostic test for the quantitative serial determination of cancer antigen CA 27.29 in human serum using the ADVIA Centau
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2720-2014·2014-10-08

    Siemens Dimension Vista CHEM 1 CAL Recall for Magnesium Calibration Error

    Siemens is recalling Dimension Vista CHEM 1 CAL lot 3GM081 because it causes under-recovery of Magnesium in patient and QC samples.

    Product
    Siemens Dimension Vista¿ CHEM 1 CAL, lot 3GM081. The CHEM 1 CAL is an in vitro diagnostic product for the calibration of Calcium (CA), Cholesterol (CHOL), Creatinine (CREA), Glucose (GLU), Lactic Acid (LA), Magnesium (MG), Thyroxine (T4), Thyroxine Uptake (TU), Blood Urea Nitr
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0733-2014·2014-01-22

    Vital Diagnostics Recalls Eon Calcium Reagent Due to High Positive Bias

    Vital Diagnostics, Inc. is recalling 213 units of Eon Calcium Reagent because high positive calcium bias was observed in plasma samples compared to serum results.

    Product
    Consult Diagnostics¿ Eon Calcium Reagent For In-Vitro Diagnostic Use PN: 1429 For the quantitative measurement of calcium in plasma and serum
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1997-2013·2013-08-28

    Beckman Coulter Recalls Hemoccult ICT Fecal Occult Blood Test Kits

    Beckman Coulter is recalling 68,116 Hemoccult ICT units due to increased sensitivity at borderline positive levels, which may cause false positives.

    Product
    Hemoccult ICT (Immunochemical Fecal Occult Blood Test) is a rapid, visually read, qualitative immunochemical chromatographic method for detection of human hemoglobin in fecal samples.
    Category
    Medical Device
    Distribution
    0 states