The Recall Desk

Hazard

Device Fragment recalls

3 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
3
Critical
0
Severe
2
Most recent
2022-12-07

Of the 3 device fragment recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2 (67%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all device fragment recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–3 of 3

  • HighFDA (Devices)·Z-0340-2023·2022-12-07

    Intuitive Da Vinci Stapler Instruments Recalled for Potential Staple Deployment Failure

    Intuitive Surgical is recalling Da Vinci Xi surgical stapling instruments due to potential staple deployment failure and device fragment generation. No injuries have been reported.

    Product
    INTUITIVE Da Vinci Xi 8mm SureForm 30 Curved-Tip Stapler Da Vinci Xi|X REF 488530 INTUITIVE Da Vinci 8mm SureForm 30 Reload 30 mm Gray 4-Row 2.0 mm Xi|X REF 48230M INTUITIVE Da Vinci 8mm SureForm 30 Reload 30 mm White 4-Row 2.5 mm Xi|X REF 48230W INTUITIVE Da Vinci 8mm…
    Category
    Medical Device
    Distribution
    24 states
  • SevereFDA (Devices)·Z-2092-2012·2012-08-08

    Zimmer Recalls Nextgen Knee Replacement Jaw Instruments Due to Fracture Risk

    Zimmer Inc. is recalling Nextgen Complete Knee Solution replacement jaws because the spring clip may fracture or fall off during use, potentially leaving fragments in the surgical site.

    Product
    Nextgen Complete Knee Solution Replacement Jaw for Use with Femoral and Provisional Impactor/Extractor, REF 00-5901-026-40, Non-Sterile Zimmer, Warsaw Indiana The instrument is attached to the femoral implant or provisional to aid in positioning and inserting the components.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2091-2012·2012-08-08

    Zimmer Recalls Nextgen Knee Instruments Due to Spring Clip Fracture Risk

    Zimmer Inc. is recalling 1,662 Nextgen Complete Knee Solution Femoral and Provisional Impactor/Extractor instruments because the spring clip may fracture or fall off during use, potentially leaving fragments in the surgical site.

    Product
    Nextgen Complete Knee Solution Femoral and Provisional Impactor/ Extractor, REF 00-5901-026-00, Non-Sterile Zimmer, Warsaw Indiana The instrument is attached to the femoral implant or provisional to aid in positioning and inserting the components.
    Category
    Medical Device
    Distribution
    Distributed nationwide