The Recall Desk

Hazard

Connectivity Failure recalls

5 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
5
Critical
0
Severe
0
Most recent
2023-03-08

Of the 5 connectivity failure recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 0 (0%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all connectivity failure recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–5 of 5

  • HighFDA (Devices)·Z-1192-2023·2023-03-08

    Alaris PC Unit 8015 wireless network connectivity failure affecting infusion pump management

    Certain Alaris PC Unit 8015 infusion pump computers with specific wireless network cards may lose network connectivity, preventing remote infusion programming and data transfer. Manual programming of infusions may be required.

    Product
    Alaris PC Unit 8015 utilizing 802.11 b/g or 802.11 a/b/g wireless network cards, with IP addresses from x.x.x.224 to x.x.x.255
    Category
    Medical Device
    Distribution
    50 states
  • ModerateFDA (Devices)·Z-1574-2022·2022-08-31

    Vanta Clinician Programmer Software Cannot Connect with Multiple Implants

    The Vanta Clinician Programmer Application may fail to connect with Vanta neurostimulators when a patient has multiple devices implanted. This prevents programming of pain therapy settings in patients with multiple implants.

    Product
    Vanta Clinician Programmer Application, Model A71200. For programming of the Medtronic Model 977006 Vanta implantable neurostimulators for pain therapy.
    Category
    Medical Device
    Distribution
    50 states
  • ModerateFDA (Devices)·Z-2554-2019·2019-10-02

    Smiths Medical Medfusion 4000 Syringe Infusion Pump Recall for Wireless Connectivity Issues

    Smiths Medical is recalling Medfusion 4000 Syringe Infusion Pumps with PharmGuard Server Software due to potential wireless network connectivity issues caused by a Radio Module defect.

    Product
    Medfusion¿ Model 4000 Syringe Infusion Pump, with PharmGuard¿ Server Software (PGS). Sold under the following names: MEDFUSION¿ 4000 Pump V1.0; MEDFUSION¿ 4000 Pump V1.1, v1.1.1, v1.1.2; MEDFUSION¿ 4000 Pump V1.1, V1.1.1, V1.1.2; MEDFUSION¿ 4000 Pump V1.5, V1.5.1; MEDFUSIO
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1220-2019·2019-05-01

    Abbott Recalls 32 St. Jude Medical Confirm Rx Insertable Cardiac Monitors

    Abbott is recalling 32 St. Jude Medical Confirm Rx Insertable Cardiac Monitors because the devices incorrectly determine that their security certificates have expired, preventing them from pairing with the mobile app.

    Product
    St. Jude Medical Confirm Rx Insertable Cardiac Monitor, REF DM3500, Sterile. Product Usage: The St. Jude Medical Confirm Rx insertable cardiac monitor (ICM) is designed to detect arrhythmias and wirelessly transmit data to the Merlin.net Patient Care Network (PCN). It is indi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1780-2013·2013-07-31

    Philips IntelliVue Smart-hopping 1.4 GHz Access Point Recalled for Signal Loss

    Philips Healthcare is recalling IntelliVue Smart-hopping 1.4 GHz Access Points due to unexpected signal loss that impacts wireless connectivity.

    Product
    Radiohead Access Point 1.4 GHz Radiohead Access Point Firmware versions: C.00.04 & C.00.05 Part Number: 989803171211 Product Usage: IntelliVue Smart-hopping 1.4 GHz Access Point provides wireless connectivity between IntelliVue devices (listed below) and the Philips Inte
    Category
    Medical Device
    Distribution
    Distributed nationwide