7 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
7
Critical
0
Severe
5
Most recent
2017-07-05

Of the 7 component disengagement recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 5 (71%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all component disengagement recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–7 of 7

  • HighFDA (Devices)·Z-2622-2017·2017-07-05

    Recall of Covidien Endo Peanut 5mm Auto Suture Blunt Dissector

    Covidien LLC is recalling 194,851 units of the Endo Peanut 5mm Auto Suture Blunt Dissector because the cotton tip may disengage due to insufficient adhesive.

    Product
    Covidien Endo Peanut 5mm Auto Suture Blunt Dissector Item Code: 173019 The instrument has indications in endoscopic surgery for swabbing small amounts of fluid or for blunt dissection of soft tissue(s) and structures, or as an aid in controlling minor intraoperative bleeding
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1468-2013·2013-06-12

    FDA Recalls Versaport Bladeless Optical Trocars Due to Seal Disengagement Risk

    The FDA is recalling 23,050 units of Versaport Bladeless Optical Trocars because seals may disengage, potentially causing components to enter the patient's cavity.

    Product
    Versaport Bladeless Optical Trocar With Fixation Cannula - 5mm Short Product Code: ONB5SHF The Versaport" Bladeless Optical 5mm trocars are intended for use in a variety of gynecologic, general, thoracic and urologic endoscopic procedures to create and maintain a port of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1469-2013·2013-06-12

    Recall of Versaport Bladeless Optical Trocar Due to Seal Disengagement

    FDA Class II recall of 126,925 Versaport trocars because seals may disengage, risking component entry into the patient's cavity.

    Product
    Versaport Bladeless Optical Trocar With Fixation Cannula - 5mm Product Code: ONB5STF The Versaport" Bladeless Optical 5mm trocars are intended for use in a variety of gynecologic, general, thoracic and urologic endoscopic procedures to create and maintain a port of entry.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1470-2013·2013-06-12

    FDA Recalls Versaport Bladeless Optical Trocars Due to Seal Disengagement Risk

    The FDA is recalling 5,364 units of Versaport Bladeless Optical Trocars because seals may disengage, potentially allowing components to enter the patient's cavity.

    Product
    Versaport Bladeless Optical Trocar With (2) Fixation Cannulae - 5mm Product Code: ONB5STF2C The Versaport" Bladeless Optical 5mm trocars are intended for use in a variety of gynecologic, general, thoracic and urologic endoscopic procedures to create and maintain a port of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1472-2013·2013-06-12

    FDA Recalls Versaport Bladeless Optical Fixation Cannulas Due to Seal Disengagement

    The FDA is recalling Versaport Bladeless Optical Fixation Cannulas because seals may disengage, potentially causing components to enter the patient's cavity.

    Product
    Versaport Bladeless Optical Fixation Cannula - 5mm Product Code: ONBFCA5ST The Versaport" Bladeless Optical 5mm trocars are intended for use in a variety of gynecologic, general, thoracic and urologic endoscopic procedures to create and maintain a port of entry.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1467-2013·2013-06-12

    FDA Recalls Versaport Bladeless Optical Trocars Due to Seal Disengagement Risk

    The FDA is recalling 2,716 units of Versaport Bladeless Optical Trocars because seals may disengage, potentially causing components to enter the patient's cavity.

    Product
    Versaport Bladeless Optical Trocar With Fixation Cannula - 5mm Long Product Code: ONB5LGF The Versaport" Bladeless Optical 5mm trocars are intended for use in a variety of gynecologic, general, thoracic and urologic endoscopic procedures to create and maintain a port of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1471-2013·2013-06-12

    FDA Recalls Versaport Bladeless Optical Fixation Cannulas Due to Seal Disengagement

    The FDA is recalling Versaport Bladeless Optical Fixation Cannulas because seals may disengage, potentially causing components to enter the patient's cavity.

    Product
    Versaport Bladeless Optical Fixation Cannula - 5mm Short Product Code: ONBFCA5SH The Versaport" Bladeless Optical 5mm trocars are intended for use in a variety of gynecologic, general, thoracic and urologic endoscopic procedures to create and maintain a port of entry.
    Category
    Medical Device
    Distribution