The Recall Desk

Hazard

Component Detachment recalls

193 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
193
Critical
0
Severe
60
Most recent
2026-09-30

Of the 193 component detachment recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 60 (31%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all component detachment recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 193

  • HighFDA (Devices)·Z-1512-2026·2026-03-18

    Link Endo-Model plateau 15-0027/15 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-0027/15 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-0027/15;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1522-2026·2026-03-18

    Link Endo-Model plateau 15-0027/12 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-0027/12 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-0027/12;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1516-2026·2026-03-18

    Link Endo-Model plateau 15-2836/11 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-2836/11 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-2836/11;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1511-2026·2026-03-18

    Link Endo-Model SL component 16-2840/05 recalled over bushing fracture

    Waldemar Link is recalling Endo-Model SL Connection Component item 16-2840/05 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/05;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1513-2026·2026-03-18

    Link Endo-Model SL component 16-2840/02 recalled over bushing fracture

    Waldemar Link is recalling Endo-Model SL Connection Component item 16-2840/02 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/02;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1518-2026·2026-03-18

    Link Endo-Model plateau 15-8521/09 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-8521/09 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-8521/09;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1519-2026·2026-03-18

    Link Endo-Model plateau 15-8521/11 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-8521/11 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-8521/11;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1515-2026·2026-03-18

    Link Endo-Model plateau 15-2835/12 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-2835/12 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-2835/12;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1517-2026·2026-03-18

    Link Endo-Model plateau 15-8030/12 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-8030/12 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-8030/12;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1514-2026·2026-03-18

    Link Endo-Model SL connection component recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model SL Connection Component item 16-2840/07 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/07;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1521-2026·2026-03-18

    Link Endo-Model plateau 15-0027/11 recalled over screw bushing fracture

    Waldemar Link is recalling Endo-Model Replacement Plateau item 15-0027/11 because the bushing on a plateau screw could detach from the screw shaft due to a longitudinal fracture.

    Product
    Endo-Model Replacement Plateau; Item Number: 15-0027/11;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V146000·2026-03-12

    Honda motorcycle handlebar lock screw may loosen and detach

    Honda is recalling certain 2023-2025 CMX300, CMX500 and CL500 motorcycles because the handlebar lock screw may loosen and detach, potentially interfering with steering.

    Product
    HONDA — HONDA SCL500, CMX300, CMX500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V141000·2026-03-12

    Jeep Wagoneer S liftgate hinge cover may detach from vehicle

    Chrysler is recalling certain 2024-2026 Jeep Wagoneer S vehicles because the liftgate hinge cover may not be properly clipped into position and may detach from the vehicle.

    Product
    JEEP — JEEP WAGONEER S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26315·2026-03-05

    HALO Magic Sleepsuits recalled because zipper heads can detach

    HALO Magic Sleepsuits in three batch codes are being recalled because the zipper head can detach from the garment, posing a choking hazard to infants.

    Product
    HALO Magic Sleepsuits
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V108000·2026-02-24

    Newmar motorhome hood stop adhesive may fail allowing detachment in transit

    Newmar is recalling certain 2018-2026 Bay Star and Bay Star Sport motorhomes because the hood stops mounting adhesive may fail, allowing the hood stop to detach while the vehicle is in transit.

    Product
    NEWMAR — NEWMAR BAY STAR SPORT, BAY STAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V097000·2026-02-19

    Range Rover panoramic sunroof side trim may not be properly secured

    Land Rover is recalling certain 2023-2026 Range Rover and Range Rover Sport vehicles because the panoramic sunroof side finisher trim may not be properly secured and can detach.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER SPORT, RANGE ROVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V089000·2026-02-17

    Winnebago View and Navion rear roof cap trim may detach

    Winnebago is recalling certain 2020-2023 View and Navion recreational vehicles because the rear roof cap aerofence trim may become loose and detach during transit.

    Product
    WINNEBAGO — WINNEBAGO VIEW, NAVION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V051000·2026-01-29

    Jeep Grand Cherokee rear coil springs may detach while driving

    Chrysler is recalling certain 2021-2023 Jeep Grand Cherokee L and 2022-2023 Grand Cherokee vehicles because the rear coil springs may be incorrectly installed and detach from the vehicle while driving.

    Product
    JEEP — JEEP GRAND CHEROKEE L, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1128-2026·2026-01-28

    Custom procedure kits recalled over inflation handles that may detach

    Merit Medical Systems is recalling its Custom Procedure Kit because the inflation device handle may detach from the syringe during a procedure.

    Product
    Merit Medical , Custom Procedure Kit Reference Numbers: K12T-04270A K12T-07956 K12T-10922B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1126-2026·2026-01-28

    Custom inflation kits recalled over inflation handles that may detach

    Merit Medical Systems is recalling 18,897 units of its Custom Inflation Kit because the inflation device handle may detach from the syringe during a procedure.

    Product
    Merit Medical , Custom Inflation Kit REF: K05-00761F K05-01717B K05-02080D K05-02090C K05-02221 K05-02338 K05-02470 K05-02954 K05-03094A K05T-00380C K05T-01674B K05T-01863 K05T-01915 K05T-01920F K05T-01955 K05T-02138 K05T-02138A K05T-02272G K05T-02272H K05T-02533 K05T-03153…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0413-2026·2026-01-28

    Custom manifold kits recalled over inflation handles that may detach

    Merit Medical Systems is recalling 2,192 Custom Manifold Kits, REF K09-13203A, because the inflation device handle may detach from the syringe during a procedure.

    Product
    Gaceniga Authentic Cuban Loaf Cake Raisins (Net Wt. 24 oz (680g)) packaged in wax paper placed in clear bag and packed in cardboard carton. 12/ 24 oz per master case.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1129-2026·2026-01-28

    Angioplasty packs recalled over inflation handles that may detach

    Merit Medical Systems is recalling 328,000 units of the Allwell Angioplasty Pack because the inflation device handle may detach from the syringe during a procedure.

    Product
    Allwell Angioplasty Pack REF: IS-30-B1/B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1124-2026·2026-01-28

    Angiographic inflation devices recalled over handles that may detach

    Merit Medical Systems is recalling 173,645 units of the Allwell Inflation Device because the inflation device handle may detach from the syringe during a procedure.

    Product
    Allwell Inflation Device, for angiographic use REF: IS-30-A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1125-2026·2026-01-28

    Waste management vascular trays recalled over inflation handles that may detach

    Merit Medical Systems is recalling 864 units of its Custom Waste Management Kit Vascular Tray because the inflation device handle may detach from the syringe during a procedure.

    Product
    Merit Medical , Custom Waste Management Kit Vascular Tray REF: K10T-05261
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1123-2026·2026-01-28

    basixCOMPAK inflation devices recalled over handles that may detach

    Merit Medical Systems is recalling 4,163,123 units of the Merit Medical Inflation Device basixCOMPAK because the inflation device handle may detach from the syringe during a procedure.

    Product
    Merit Medical Inflation Device.basixCOMPAK.30 atm/bar.20 mL Reference Numbers: ENDO-AN2030/B IN4130/CNK IN4130/H IN4130/JPH IN4130/K IN4130/KRK IN4130/L IN4130/T IN4230/JPH IN4230/K IN4330/CNK IN4330/K IN4352/K IN4430/K IN4530/CNK IN4530/K IN4530/T IN4802/K IN4802/T IN4852/K…
    Category
    Medical Device
    Distribution
    Distributed nationwide