The Recall Desk

Hazard

Clostridium Botulinum recalls

265 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
265
Critical
35
Severe
152
Most recent
2026-07-01

Of the 265 clostridium botulinum recalls we have scored against our rubric, 35 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 152 (57%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all clostridium botulinum recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

151–175 of 265

  • SevereFDA (Food)·F-1652-2022·2022-09-07

    Uproot Oatmilk Organic Oats Recalled for Bacterial Contamination Risk

    Uproot Oatmilk Organic Oats is recalled nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Affected units have lot code 8502 with best-by date 02/22/2023.

    Product
    Uproot Oatmilk Organic Oats 8 fl oz. (240mL) UPC 8 60002-91543 2. Manufactured for Uproot, Inc., New York, NY 10005. Serve chilled, refrigerate after opening and use within 7 days. Sold in 18-count case UPC 10860002915439 .
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1676-2022·2022-09-07

    Oatly Oat Drink Recalled for Bacterial Contamination Findings

    Oatly Oat Drink Deluxe 330ml is being recalled for findings of Cronobacter sakazakii and Clostridium botulinum. Approximately 53.8 million units nationwide are affected. Consumers should not consume the product.

    Product
    PROUCT WAS NOT DISTRIBUTED IN US. The Original Oatly! Oat Drink Deluxe 330ml. UPC 7 394376 619021 18 count case UPC 27394376619025. Shake well before drinking. Produced in the USA. Oatly AB, Stora Varvsgatan 6a, SE-211 19 Malmo.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1661-2022·2022-09-07

    Whey Protein Drink Recalled Nationwide for Potential Bacterial Contamination

    Optimum Nutrition Gold Standard 100% Whey Vanilla is being recalled nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Affected product has lot code 2321 with best-by date 08/20/2022.

    Product
    Optimum Nutrition Gold Standard 100% Whey Vanilla 11 fl oz (325mL). UPC 7 48927-06410 0. Shake well. Best when served chilled. Manufactured for Optimum Nutrition, Inc., 3500 Lacey Road, Suite 1200, Downers Grove, IL 60515
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1615-2022·2022-09-07

    Lyons Barista Style Almond Beverage Recalled for Potential Bacterial Contamination

    Lyons Magnus is recalling Lyons Barista Style Almond non-dairy beverage nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Consumers should not consume the affected products.

    Product
    Lyons Barista Style Almond, Non-Dairy Beverage. Plant-Based Milk. 32 FL OZ (1 QT) 946mL UPC 0 45796-10165 4. 12 count case UPC 10045796101651. Shake Well before Serving. After opening keep refrigerated and use within 7 days. Lyons Magnus, Fresno, CA 93702.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1665-2022·2022-09-07

    Pediatric Nutrition Formula Recalled for Bacterial Contamination Risk

    Kate Farms Pediatric Peptide formula is being recalled nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum, high-risk pathogens. The formula is designed for children ages 1 to 13.

    Product
    kate farms Pediatric Peptide 1.0 Cal/mL, Vanilla, Sole-Source Nutrition Formula. 250 mL (8.45 fl oz) UPC 8 11112-03052 2. 24 count case UPC 00811112030539. A Oral and Tube Feeding Formula. Specifically designed for children ages 1-13 years old. Not suitable for infants les
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1654-2022·2022-09-07

    Organic Valley Chocolate Milk recalled for pathogen contamination

    Lyons Magnus is recalling Organic Valley Organic Chocolate Milk nationwide due to findings of Cronobacter sakazakii and Clostridium botulinum. Consumers should discard affected products or return them to the store.

    Product
    Organic Valley Organic 1% Milkfat Lowfat Chocolate Milk. Garde A Vitamin A&D UHT. 8 fl oz (236mL) UPC 0 93966-00838 8. Chill and Shake before serving. Refrigerate after opening. Distributed by CROPP Cooperative La Farge, WI 54639. 12 Count wrap UPC 00093966008548
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1667-2022·2022-09-07

    Kate Farms Nutrition Shake recalled for potential bacterial contamination

    Kate Farms Nutrition Shake (Coffee, 11 fl oz) is being recalled nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. The recall affects products with lot codes 7331 and 8031.

    Product
    kate farms Nutrition Shake, Coffee. 11 fl oz (325 mL) UPC 8 11112-03062 1. 12 count case UPC 00811112030638. Shake Well. After opening, refrigerate and use within 4 days. Made for Kate Farms, Inc., 101 Innovation Place, Santa Barbara, CA 93708
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1651-2022·2022-09-07

    Plant-Based Protein Shake Vanilla Recalled for Potential Bacterial Contamination

    Tone It Up Plant-Based Protein Shake Vanilla is being recalled nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Consumers should not consume the product and should contact the distributor.

    Product
    Tone It Up Plant-Based Protein Shake Vanilla. 11 fl oz. UPC 8 10745-03177 7. Sold in 4-count case UPC 00810745032361. Shake Well. Serve Cold. Refrigerate after opening and use within 48 hours. Distributed by Tone It Up, Manhattan Beach, CA
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1658-2022·2022-09-07

    Protein Drink Recalled for Potential Cronobacter and Botulinum Contamination

    Lyons Magnus recalls Rejuvenate Muscle Health+ Vanilla nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Consumers should not consume affected products.

    Product
    Rejuvenate Muscle Health+ Vanilla. 11 fl oz. (330mL) UPC 6 29046-50402 2. Serve Cold, shake well. Manufactured exclusively for Element Nutrition, Ltd., 1887 Whitney Mesa Dr. #6020, Henderson, NV 89014. 4-count Case UPC 629046544028.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1646-2022·2022-09-07

    Lyons Ready Care Vanilla Nutritional Drink Recalled Nationwide

    Lyons Magnus recalls Lyons Ready Care No Sugar Added Vanilla nutritional drink nationwide due to findings and potential for Cronobacter sakazakii and Clostridium botulinum contamination.

    Product
    Lyons Ready Care No Sugar Added 1.7 high Calorie High Protein Nutritional Drink Vanilla. 32 fl oz. (1QT) 946mL. UPC 0 45796-10047 3. Mildy thick Nectar Consistency. Refrigerate prior to serving. Shake well. Sold in 12-count case UPC 10045796100470. Lyons Magnus, Fresno
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1674-2022·2022-09-07

    Oatly Oat Drink Chocolate Recalled Due to Pathogen Contamination Risk

    Lyons Magnus is recalling Oatly Oat Drink Chocolate nationwide due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Consumers should not consume the affected product.

    Product
    The Original Oatly! Oat Drink Chocolate 11 fl oz (330ml). UPC 1 90646-63015 7. 18 count case UPC 20190646630151. Distributed by Oatly Inc., 220 E 42ndSt., Ste. 409A, New York, NY 10017.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1631-2022·2022-09-07

    Sysco Imperial Dairy Drink Recalled for Cronobacter and Botulism

    Lyons Magnus recalled Sysco Imperial Thickened Dairy Drink nationwide due to potential Cronobacter sakazakii and Clostridium botulinum contamination. The FDA Class I recall affects over 53 million units distributed in 8 oz and 32 oz containers.

    Product
    Sysco Imperial Thickened Dairy Drink. Moderately Thick Honey Consistency. Pasteurized - Made with Grade A 2% Fat Milk, Vitamins A & D. Packaged in the following sized Tetra Pak containers: 1. 8 FL OZ (237 mL) UPC 0 74865-94550 9. Reorder # 0429357. 24 count case UPC
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1666-2022·2022-09-07

    Kate Farms Nutrition Formula Recalled for Cronobacter and Botulinum Risk

    Kate Farms Standard nutrition formula in 325 mL bottles is being recalled due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Approximately 53,818,025 units distributed nationwide.

    Product
    kate farms Standard 1.0 Cal/mL, Vanilla, Sole-Source Nutrition Formula. 325 mL (11 fl oz) UPC 8 51823-00663 8. 12 count case UPC 00851823006683. Shake Well. A ready-to-use oral and tube feeding formula with intact organic pea protein. Made for Kate Farms, Inc., 101 Innovat
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1640-2022·2022-09-07

    Stumptown Cold Brew Coffee Recalled for Potential Bacterial Contamination

    Stumptown Cold Brew Coffee with Oat Milk Original is being recalled due to potential contamination with Cronobacter sakazakii and Clostridium botulinum. Affected products were distributed nationwide.

    Product
    Stumptown Cold Brew Coffee with Oat Milk Original. Plant Based. Low Sugar. Made with Oatly! 11 Fl Oz. 325 ML. UPC 8 55186-00687 8. Sold in 12-count case UPC 108551860006875. Manufactured for Stumptown Coffee Roasters, 100 SE Salmon St. Portland, OR 97214
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1298-2022·2022-06-22

    Zesty Sweet Peppers Recalled Due to Potential Botulinum Contamination

    Soul Cedar Farm's Zesty Sweet Peppers are being recalled due to potential contamination with Clostridium botulinum. Testing found a pH level of 5.57, which can support dangerous pathogen growth in shelf-stable foods.

    Product
    Zesty Sweet Peppers. Shelf stable product in glass container. Net wt. 8 oz (372 g). The label is read in parts: "***Zesty Sweet Peppers *** Ingredients: Sweet Peppers, Balsamic Vinegar (organic wine vinegar, organic concentrated grape must), Olive Oil, Onion, Lemon Juice, Garl
    Category
    Food
    Distribution
    1 state
  • CriticalFDA (Food)·F-0058-2020·2019-10-30

    Roland Brand Red Caviar Recalled for Potential Botulism Contamination

    Roland Foods is recalling specific jars of Red Caviar due to potential Clostridium botulinum contamination. Consumers should check their pantries for the listed UPCs and batch codes.

    Product
    Roland Brand Red Caviar - Whole Grain Lumpfish (Lumpfish Roe) packed in glass jars - 2oz & 2x2oz, UPC: 41224202023; 3.5oz, UPC: 41224202207; 12oz, UPCs: 41224202405 & 41224202420
    Category
    Food
    Distribution
    27 states
  • CriticalFDA (Food)·F-0057-2020·2019-10-30

    Roland Black Caviar Recalled for Potential Botulism Contamination

    Roland Foods is recalling specific jars of Black Caviar due to potential Clostridium botulinum contamination. Consumers should check their pantries for the listed UPCs and batch codes.

    Product
    Roland Brand Black Caviar - Whole Grain Lumpfish (Lumpfish Roe) packed in glass jars - 2oz & 2x2oz, UPC: 41224200029; 3.5oz, UPC: 41224200203; 12oz, UPCs: 41224200401 & 41224200425
    Category
    Food
    Distribution
    27 states
  • SevereFDA (Food)·F-2094-2019·2019-09-04

    AWERS Grained Salmon Caviar Recalled for Potential Botulism Contamination

    AWERS Inc is recalling Grained Salmon Caviar due to potential Clostridium botulinum contamination. Consumers should check their refrigerators for the specific product details.

    Product
    Grained Salmon Caviar 95g (Sockeye Salmon Caviar), refrigerated, packed in a metal tin with Cyrillic lettering. The tin is green, with red and white writing with an easy open pull lid. UPC 8 85202 00044 3. The label is read in parts: "***GRAINED SALMON CAVIAR ***INGREDIENTS:
    Category
    Food
    Distribution
    5 states
  • SevereFDA (Food)·F-1174-2019·2019-03-27

    Smoked Alaska Silver Salmon Recalled for Botulism Risk

    Smoked Alaska Seafoods is recalling 6.5 oz. jars and cans of Smoked Silver Salmon due to potential Clostridium botulinum contamination.

    Product
    Smoked Silver Salmon, brand Smoked Alaska, packaged in 6.5 oz. glass jars or cans. The product label is read in parts: "***SMOKED WILD ALASKA SILVER SALMON*** SMOKED ALASKA*** NET WT. 6.5 OZS. Ingredients: Natural Alder Smoked Silver Salmon, Brown Sugar, Salt *** PO BOX 87025
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1154-2019·2019-03-13

    Ocean Beauty Seafoods Recalls Hot Smoked Salmon for Botulism Risk

    Ocean Beauty Seafoods is recalling Hot Smoked Salmon Variety Packs sold at Aldi due to potential Clostridium botulinum contamination from low salt content.

    Product
    Hot Smoked Salmon Variety Pack. ITEM # F3120SS9, Aldi ID# 51326. Each master case contains 12/4 oz. packs (4 packs of each flavor - Traditional, Cracked Black Pepper, and Cajun Flavored). Traditional, Hot Smoked Salmon, 4 oz. UPC 041498234881. Cajun Flavored, Hot Smoked S
    Category
    Food
    Distribution
    3 states
  • CriticalFDA (Food)·F-0841-2019·2019-02-13

    Bornstein Seafoods Recalls Unpasteurized Dungeness Crab Meat Due to TTI Error

    Bornstein Seafoods is recalling unpasteurized Dungeness crab meat because incorrect Time Temperature Indicators were applied, potentially masking temperature abuse and allowing Clostridium botulinum growth.

    Product
    5-pound cans of unpasteurized, ready-to-eat, Dungeness crab meat, packaged in reduced oxygen metal cans that were shipped with Fresh-Check B Time Temperature Indicator (TTIs). Product was shipped frozen. The label is read in parts: "***BORNSTEIN SEAFOODS ***WILD Dungeness C
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Food)·F-0874-2019·2019-02-13

    Apple Foods Recalls Diced Onions Due to Botulism Risk

    Apple Foods, Inc. is recalling diced onions due to a potential for Clostridium botulinum growth and toxin formation.

    Product
    Diced Onions, packaged in vacuum sealed clear polybags, 5 pounds each, four packages per case. Product is sold under brand name Apple Foods. This product distributed with the words "Keep Refrigerated" on case labels but it does not instruct to keep refrigerated under 38 F. T
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-0877-2019·2019-02-13

    Apple Foods Coleslaw Recalled for Potential Botulism Risk

    Apple Foods is recalling 5-pound bags of coleslaw due to a potential for Clostridium botulinum growth and toxin formation.

    Product
    Coleslaw (shredded white cabbage), packaged in vacuum sealed clear polybags, 5 pounds each, four packages per case. Product is sold under brand name Apple Foods. This product distributed with the words "Keep Refrigerated" on case labels but it does not instruct to keep refrig
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-0762-2019·2019-01-30

    Del Monte Fiesta Corn Recalled for Potential Botulism Risk

    Del Monte is recalling Fiesta Corn seasoned with Red & Green Peppers because incorrect thermal processing may allow Clostridium botulinum growth.

    Product
    Del Monte Quality Fresh Cut Harvest Selects Fiesta Corn seasoned with Red & Green Peppers. NET WT 15.25 oz. (432 g); UPC 0 24000 02770; Ingredient: Vegetables (corn, red and green peppers) water, sea salt. Distributed by Del Monte Foods, Walnut Creek, CA 94598
    Category
    Food
    Distribution
    34 states
  • SevereFDA (Food)·F-1761-2018·2018-08-15

    Kraft Heinz Recalls Taco Bell Salsa Con Queso Due to Botulism Risk

    Kraft Heinz is recalling Taco Bell Salsa Con Queso Mild jars nationwide due to a risk of Clostridium botulinum growth.

    Product
    Taco Bell Salsa Con Queso Mild 15oz retail jar UPC 21000024490 packaged in 12 count and 8 count cases
    Category
    Food
    Distribution
    Distributed nationwide