The Recall Desk

FDA (Drugs) recall action 93710

Denver Solutions, LLC DBA Leiters Health recalled 6 products on 2024-02-07

The FDA (Drugs) publishes a recall like this one as 6 separate product records. They share a firm, a date and a cause; this page is all of them in one place, so the scale of the action is visible rather than spread across 6 pages.

Products
6
Announced
2024-02-07
Critical
3
Units
82,176

Why these products were recalled

Superpotent Drug: semi-automated IV bag filling system can malfunction and provide a double dose of drug product to IV bags.

The agency’s own wording, quoted from the enforcement report.

The unit total adds up the quantities the agency stated for each product. Where a product record gave no figure, or gave a weight rather than a count, it contributes nothing — so the real total is at least this, never less.

1–6 of 6

  • CriticalFDA (Drugs)··2024-02-07

    Fentanyl Citrate IV Bags Recalled Due to Double-Dose Filling System Malfunction

    Denver Solutions recalled 8,976 IV bags of fentanyl citrate nationwide due to a malfunction in the semi-automated filling system that could deliver double the intended dose.

    Product
    FentaNYL citrate PF, 1000 mcg per 100 mL 0.9% Sodium Chloride (10 mcg per mL), Item F3355, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-072-41.
    Category
    Distribution
    0 states
  • CriticalFDA (Drugs)··2024-02-07

    Phenylephrine IV Bags Recalled for Double-Dose Filling System Malfunction

    Denver Solutions is recalling 29,016 Phenylephrine HCl IV bags distributed nationwide. A filling system malfunction can result in some bags receiving double doses of this potent injectable drug.

    Product
    PHENYLephrine HCl 20 mg per 250 mL 0.9% Sodium Chloride (80 mcg per mL), Item F3360, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-148-94.
    Category
    Distribution
    0 states
  • HighFDA (Drugs)··2024-02-07

    IV Phenylephrine Bags Recalled Due to Potential Double-Dose Delivery System Malfunction

    Denver Solutions is recalling 12,564 bags of PHENYLephrine HCl IV solution nationwide due to a semi-automated filling system malfunction that could dispense double doses to patients.

    Product
    PHENYLephrine HCl 40 mg per 250 mL 0.9% Sodium Chloride (160 mcg per mL), Item F3352, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-150-82.
    Category
    Distribution
    0 states
  • SevereFDA (Drugs)··2024-02-07

    FentaNYL Citrate IV Bags Recalled Due to Double-Dose Filling System Malfunction

    FentaNYL citrate intravenous bags are recalled nationwide because a semi-automated filling system can malfunction and deliver double the intended dose. Patients and healthcare providers should immediately quarantine affected lots.

    Product
    FentaNYL citrate PF, 2500 mcg per 250 mL 0.9% Sodium Chloride (10 mcg per mL), Item F3342, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-072-82.
    Category
    Distribution
    0 states
  • SevereFDA (Drugs)··2024-02-07

    Vancomycin IV bags recalled due to filling system malfunction causing double doses

    Denver Solutions is recalling 10,152 Vancomycin IV bags nationwide because a filling system malfunction can deliver double doses of the antibiotic medication.

    Product
    VANCOmycin HCl PF 1.25g added to 0.9% Sodium Chloride 250 mL IV bag, Item F3206, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-028-68.
    Category
    Distribution
    0 states
  • CriticalFDA (Drugs)··2024-02-07

    FDA Recalls Vancomycin IV Bags Due to Dosing System Malfunction

    Denver Solutions is recalling 7,548 IV bags of vancomycin due to a manufacturing system malfunction that can deliver double doses. The product was distributed nationwide.

    Product
    VANCOmycin HCl PF 1.5g added to 0.9% Sodium Chloride 250 mL IV bag, Item F3208, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-029-68.
    Category
    Distribution
    0 states