FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

24651–24675 of 40339

  • LowFDA (Devices)·Z-1002-2018·2018-03-21

    Arrow International Recalls Arrowg+ard Blue Catheters Due to Missing Labels

    Arrow International Inc. is recalling 23,904 Arrowg+ard Blue central venous catheters because some units are missing stickers with lot, expiration, and UDI information.

    Product
    ARROWg+ard Blue Product Usage: The Arrow¿ CVC is indicated to provide short-term (< 30 days) central venous access for treatment of diseases or conditions requiring central venous access including, but not limited to: multiple infusions of fluids, medications, or…
    Category
    Medical Device
    Distribution
    7 states
  • LowFDA (Devices)·Z-0978-2018·2018-03-21

    Philips HeartStart XL+ Defibrillator Software Update Recall

    Philips is recalling 4,315 HeartStart XL+ defibrillators in China to update software that improves device readiness information.

    Product
    HeartStart XL+ Defibrillator/Monitor The HeartStart XL+ is intended for use in a hospital setting by qualified medical personnel trained in the operation of the device and qualified by training in basic life support, advanced life support, or defibrillation. It must be used…
    Category
    Medical Device
    Distribution
    0 states
  • LowFDA (Devices)·Z-0970-2018·2018-03-21

    Randox Immunoassay Premium Plus Controls Recalled for Stability Issues

    Randox Laboratories is recalling Immunoassay Premium Plus Controls because the ACTH component does not meet the stability claims in the product instructions.

    Product
    Immunoassay Premium Plus Controls (3x4x5mL and 12x5mL packages)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1001-2018·2018-03-21

    Arrow International Recalls CVC Kits Missing Lot Number Stickers

    Arrow International is recalling 23,904 Arrowg+ard Blue Large-Bore Multi-Lumen CVC Kits because some units may be missing stickers containing lot numbers, expiration dates, and UDI information.

    Product
    ARROWg+ard Blue¿ Large-Bore Multi-Lumen CVC Kit Product Usage: The Arrow¿ CVC is indicated to provide short-term (< 30 days) central venous access for treatment of diseases or conditions requiring central venous access including, but not limited to: multiple infusions of…
    Category
    Medical Device
    Distribution
    7 states
  • LowFDA (Devices)·Z-1004-2018·2018-03-21

    Arrow International Recalls CVC Kits Missing Lot and UDI Stickers

    Arrow International Inc. is recalling 23,904 Arrowg+ard BLUE PLUS CVC Kits because some units are missing stickers containing lot numbers, expiration dates, and UDI information.

    Product
    ARROWg+ard BLUE PLUS Pressure Injectable Two- Lumen CVC Kit Product Usage: The Arrow¿ CVC is indicated to provide short-term (< 30 days) central venous access for treatment of diseases or conditions requiring central venous access including, but not limited to: multiple…
    Category
    Medical Device
    Distribution
    7 states
  • LowFDA (Devices)·Z-0996-2018·2018-03-21

    Arrow PICC Kits Recalled for Missing Lot and Expiration Labels

    Arrow International is recalling 23,904 PICC kits because some units are missing stickers with lot numbers, expiration dates, and UDI information.

    Product
    Pressure Injectable Multi- Lumen Central Venous Pressure Injectable ARROW(R) PICC Kit with Chlorag+ard(R) Technology Product Usage: The Arrow¿ CVC is indicated to provide short-term (< 30 days) central venous access for treatment of diseases or conditions requiring central…
    Category
    Medical Device
    Distribution
    7 states
  • SevereFDA (Devices)·Z-0908-2018·2018-03-14

    FDA Recalls 163 Endo GIA Radial Reloads Due to Manufacturing Error

    The FDA is recalling 163 Endo GIA Radial Reloads with Tri-Staple Technology because the device cartridge disengaged during use due to a manufacturing error.

    Product
    Endo GIA" Radial Reload with Tri-Staple" Technology The Endo GIA radial reloads with Tri-Staple Technology have application in open or minimally invasive general abdominal, gynecologic and thoracic surgery for resection and transection of tissue and creation of anastomosis…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0909-2018·2018-03-14

    Roche cobas 6000 Modular Series System Warning Added to Prevent Operator Injury

    Roche Diagnostics is adding a warning to cobas 6000 and 8000 Modular Series Operator Manuals to prevent operator injury during maintenance.

    Product
    cobas 6000 Modular Series system; Part Numbers: 1. 04745914001 cobas c 501 module; 2. 05036453001 cobas 6000 UL c 501 + Core Fix configuration; 3. 05036453692 - cobas 6000 UL + CORE CU; and 4. 05860636001 cobas 6000 c 501 (UL) V
    Category
    Medical Device
    Distribution
    51 states
  • HighFDA (Devices)·Z-0922-2018·2018-03-14

    Abbott ARCHITECT c8000 Cuvette Segment Recall for False Test Results

    Abbott is recalling ARCHITECT c8000 Cuvette Segments because a detached post can cause falsely depressed patient results on c4000, c8000, and c16000 instruments.

    Product
    ARCHITECT c8000 Cuvette Segment, Part #01G46-01/01G06, a component to the ARCHITECT Clinical Chemistry system. There are 11 segments with each cuvette segment holding 15 cuvettes for a total of 165 cuvettes per reaction carousel. The firm name on the label is Abbott…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0903-2018·2018-03-14

    Synthes Reaming Rods Recalled for Potential Sterility Seal Defects

    Synthes (USA) Products LLC is recalling 1,144 sterile 2.5 mm Reaming Rods due to potential gaps in the package seal that may compromise sterility.

    Product
    2.5 mm Reaming Rod, Ball tip, 1150 mm, sterile, Part Number: 351.708S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0923-2018·2018-03-14

    Abbott Recalls ARCHITECT c16000 Cuvette Segments Due to Falsely Depressed Results

    Abbott Laboratories is recalling cuvette segments for the ARCHITECT Clinical Chemistry system because detached segment posts may cause falsely depressed patient test results.

    Product
    ARCHITECT c16000 Cuvette Segment, Part #09D32-05/ 03L77, a component to the ARCHITECT Clinical Chemistry system. There are 15 segments with each cuvette segment holding 11 cuvette pairs (22 cuvettes) for a total of 165 cuvettes pairs or a total of 330 cuvettes (22 cuvettes x 15…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0927-2018·2018-03-14

    Medtronic O-arm O2 Imaging System Recalled for Electrical Shock Risk

    Medtronic is recalling 449 O-arm O2 Imaging Systems because servicing internal components may cause an electrical short, posing a shock hazard to field service technicians.

    Product
    O-arm¿ O2 interventional fluoroscopic x-ray system; Catalog Number: B1-700-02000 The O-arm O2 Imaging System is a mobile x-ray system designed for 2D fluoroscopic and 3D imaging for adult and pediatric patients weighting 60 lbs or greater and having an abdominal thickness of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0846-2018·2018-03-14

    Mindray A-Series Anesthesia Delivery System Software Recall

    Mindray is recalling 2,875 A-Series anesthesia delivery systems due to a software issue that may apply incorrect settings or skip startup leak tests.

    Product
    A-Series A3/A5 Anesthesia Delivery System; Model Numbers: 0633F-01000-0X (A3) and 0631F-01000-0X (A5) Product Usage: The A-Series Anesthesia System is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic, and to maintain a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0844-2018·2018-03-14

    Toshiba Fluoroscopic X-Ray Systems Recalled for Ceiling Drive Bolt Loosening

    Toshiba American Medical Systems is recalling 29 INFX-8000V and INFINIX CF-I/BP PLUS systems because fastening bolts on the ceiling drive loosened, disabling operation.

    Product
    INFX-8000V Fluoroscopic X-Ray Systems; INFINIX CF-I/BP PLUS CARDIAC SYSTEM
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0907-2018·2018-03-14

    Synthes Recalls Sterile Light Clip for Oracle Retractor Due to Potential Lack of Sterility

    Synthes (USA) Products LLC is recalling sterile Light Clips for the Oracle Retractor because potential gaps in the package seal may compromise sterility. The product is used during orthopedic surgery.

    Product
    Light Clip for Oracle Retractor, sterile, Part Number: 03.809.925S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0847-2018·2018-03-14

    Mindray A7 Anesthesia Delivery System Recalled for Software Defect

    Mindray is recalling A7 Anesthesia Delivery Systems because a software issue may cause incorrect settings to be applied or the startup leak test to be skipped.

    Product
    A-Series A7 Anesthesia Delivery System; Model Number: 0632F-PA0000X (A7) Product Usage: The A-Series Anesthesia System is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic, and to maintain a patient s ventilation. The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0919-2018·2018-03-14

    Zimmer Biomet Recalls Sirus Drill Instruments Due to Cleaning Concerns

    Zimmer Biomet is recalling 127 Sirus Drill instruments because they may not be adequately cleaned, potentially leading to infection.

    Product
    Sirus Drill 13mm diameter trauma instrument used for preparation of bone in Trauma, Hip and Shoulder surgeries.; Model Number: 02.00020.040
    Category
    Medical Device
    Distribution
    32 states
  • HighFDA (Devices)·Z-0840-2018·2018-03-14

    Philips Recalls Brilliance Big Bore Oncology CT Scanners Due to Software Errors

    Philips Medical Systems is recalling 11 Brilliance Big Bore Oncology CT scanners due to software errors that may affect image generation and display settings.

    Product
    Brilliance Big Bore Oncology CTwith 4.2.0 software version. Model #' 728243 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0863-2018·2018-03-14

    Bausch & Lomb Recalls LaserEdge Ophthalmic Knives Due to Dull Blades

    Bausch & Lomb Inc is voluntarily recalling LASEREDGE Knives for ophthalmic surgery because an atypical volume of complaints indicates dull blades. The recall affects products lacking specific electro-polish and penetration force testing.

    Product
    LASEREDGE Knives, CLEAR CORNEAL ANGLED 2.855MM GUARDED (6/BOX), REF/PRODUCT CODE E7528G, STERILE, Rx Only Product Usage: The LaserEdge Knives are intended for ophthalmic surgery. There is no therapeutic use and they are available to surgeons for use in procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0839-2018·2018-03-14

    Philips Brilliance Big Bore CT Software Recall for Image Generation Errors

    Philips is recalling 119 Brilliance Big Bore CT scanners due to software errors that may prevent image generation or display incorrect settings.

    Product
    Brilliance Big Bore Radiology CT with 4.2.0 software version. Model #' 728244 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0843-2018·2018-03-14

    Toshiba INFX-8000C Fluoroscopic X-Ray Systems Recalled for Ceiling Drive Defect

    Toshiba American Medical Systems Inc is recalling 19 INFX-8000C Fluoroscopic X-Ray Systems because fastening bolts on the ceiling drive loosened, causing the device to disable during operation.

    Product
    INFX-8000C Fluoroscopic X-Ray Systems
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0835-2018·2018-03-14

    Stryker Recalls StrykeFlow 2 System Due to Bioburden Testing Results

    Stryker is recalling 60,753 units of the StrykeFlow 2 System because routine bioburden testing found levels higher than internal acceptable rates.

    Product
    StrykeFlow 2 System, labeled sterile. Includes the following: a. STRYKER LAPAROSCOPIC SUCTION IRRIGATOR, Suction/Irrigator 2 (Model 0250070500); b. STRYKER STRYKEFLOW SUCTION IRRIGATOR, Disposable Strykeflow S/I Tip (Model 0250070505); c. STRYKER STRYKEFLOW SUCTION…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0921-2018·2018-03-14

    Abbott ARCHITECT c4000 Cuvette Segment Recall for Potential False Results

    Abbott is recalling ARCHITECT c4000 Cuvette Segments because a detached post can cause falsely depressed patient results in adjacent cuvettes.

    Product
    ARCHITECT c4000 Cuvette Segment, Part #02P75-01/02P24, a component to the ARCHITECT Clinical Chemistry system. There are 9 segments with each cuvette segment holding 11 cuvettes for a total of 99 cuvettes per reaction carousel. The firm name on the label is Abbott…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0906-2018·2018-03-14

    Synthes Recalls 2.5 mm Titanium Calibrated Reaming Rods Due to Sterility Concerns

    Synthes (USA) Products LLC is recalling 63 units of 2.5 mm Titanium Calibrated Reaming Rods because potential gaps in the package seal may have compromised product sterility.

    Product
    2.5 mm Titanium Calibrated Reaming Rod, 850 mm, Part Number: 359.083S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide